Full Early Atrial Diagnostics in Single Chamber ICD Patients Using the DX Lead and Home Monitoring in Brazil.
NCT04869527 · Status: ACTIVE_NOT_RECRUITING · Type: OBSERVATIONAL · Enrollment: 50
Last updated 2024-10-15
Summary
To demonstrate the value and benefits of BIOTRONIK's exclusive DX technology in assessing the incidence of supraventricular arrhythmias, mainly atrial fibrillation (AF), in patients with an indication for single chamber ICDs.
Effects of the DX technology on related events, such as delivery of therapies and medical management, including eventual complications.
Extended benefits offered by DX devices when associated with daily remote monitoring, by means of BIOTRONIK's Home Monitoring Service Center (HMSC).
Conditions
- Arrhythmias, Cardiac
Interventions
- DEVICE
-
BIOTRONIK ICDs with DX Technology
The BIOTRONIK DX system offers a single chamber ICD that enables sensing of atrial signals through floating atrial dipoles, using a single ventricular lead. This technology enables enhanced arrhythmia diagnosis based on atrial and ventricular electrograms and, in addition, early diagnosis and automatic transmission of AF and heart failure (HF) diagnostic data. The DX technology provides several features in a single chamber device that are usually only found in dual chamber devices, including atrial diagnostics and SVT discrimination - early detection of SAF, increased diagnostics accuracy, dual-chamber discrimination. Nevertheless, the benefits of a single chamber device are preserved: reduced lead complications, reduced procedure complexity, elimination of costs for atrial lead. The DX system also integrates with BIOTRONIK Home Monitoring, allowing physicians to remotely follow their patients' clinical and device statuses with daily updates.
Sponsors & Collaborators
-
Irmandade Santa Casa de Misericórdia de Porto Alegre
collaborator OTHER -
Biotronik SE & Co. KG
lead INDUSTRY
Principal Investigators
-
Carlos CK Kalil, M.D., Ph.D. · Santa Casa de Misericórdia de Porto Alegre - Brugada Institute
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-10-05
- Primary Completion
- 2024-04-30
- Completion
- 2025-04-30
Countries
- Brazil
Study Locations
More Related Trials
-
Diagnostic Accuracy of WEARable TECHnology Single-lead ECG in Detecting Cardiac Arrhythmias
NCT05298553 ·Status: COMPLETED ·Phase: NA
-
Home-Monitoring in Implantable Cardioverter Defibrillator (ICD) Patients
NCT00787683 ·Status: UNKNOWN ·Phase: NA
-
Safety and Performance Aspects of CRT-DX System in Patients With Sinus Rhythm
NCT03839121 ·Status: COMPLETED
-
Ventricular Arrhythmias Incidence According to Sleep Apnea Syndrome in Implantable Cardioverter-Defibrillator (ICD) Patients
NCT00708786 ·Status: COMPLETED ·Phase: PHASE4
-
Cologne Cardioversion Study
NCT02241382 ·Status: COMPLETED ·Phase: NA
-
ECG Optimization of CRT: Evaluation of Mid-term Response
NCT01439529 ·Status: COMPLETED ·Phase: PHASE3
-
TReatment of Atrial Fibrillation With Dual dEfibrillator in Heart Failure Patients
NCT00345592 ·Status: COMPLETED ·Phase: PHASE4
-
Combined Use of BIOTRONIK Home Monitoring and Predefined Anticoagulation to Reduce Stroke Risk
NCT00559988 ·Status: TERMINATED ·Phase: PHASE4
-
Study to Verify Proper Detection of Supraventricular Tachyarrhythmia With Single-Lead Dual-Chamber Implantable Cardioverter-Defibrillators (ADRIA)
NCT00324662 ·Status: COMPLETED ·Phase: PHASE4
-
Non-invasive Tool to Assess Electrophysiological Mechanisms in Cardiac Arrhythmias
NCT05772182 ·Status: COMPLETED
-
Assessment of Ventricular Arrhythmia Risk After CRT-D Replacement for Patients With Primary Prevention Indication
NCT02323503 ·Status: COMPLETED
-
Comparative Analysis in Detection of Atrial Arrhythmia and ECG Quality in Three Different Insertable Cardiac Monitors
NCT04471584 ·Status: UNKNOWN ·Phase: NA
-
Efficacy of the ATP Switch Automatic Programming in Implantable Cardioverter Defibrillator (ICD) and Cardiac Resynchronization Therapy Defibrillator (CRT-D) Implanted Patients
NCT01169246 ·Status: TERMINATED
-
BIO|CONCEPT.BIOMONITOR III
NCT03850327 ·Status: COMPLETED ·Phase: NA
-
BIO|CONCEPT.BIOMONITOR-HF Collect Clinical Data From Heart Failure Patients Using BIOMONITOR Devices With a Study Specific Research Software
NCT06989580 ·Status: RECRUITING ·Phase: NA
-
Development of a Novel Convolution Neural Network for Arrhythmia Classification
NCT03662802 ·Status: COMPLETED
-
Benefits of Implantable Cardioverter Defibrillator Follow-up Using Remote Monitoring
NCT00989417 ·Status: COMPLETED ·Phase: NA
-
Observation of Clinical Routine Care for Patients With BIOTRONIK Implantable Cardiac Monitors (ICMs)
NCT04075084 ·Status: RECRUITING
-
Septal Mapping And Resynchronisation Therapy- (SMART) Study
NCT04595305 ·Status: COMPLETED ·Phase: NA
-
Post Market Clinical Follow-up of CRT-DX Therapy With Lumax 640/740 HF-T
NCT01930695 ·Status: COMPLETED
-
Master Study of the Acticor/Rivacor ICDs/CRT-Ds and the Plexa ProMRI S DX Lead
NCT03891329 ·Status: COMPLETED ·Phase: NA
-
Optimization of Cardiac Resynchronization Therapy by Non-Invasive Imaging of Cardiac Electrophysiology
NCT04662970 ·Status: RECRUITING ·Phase: NA
-
Home Monitoring in Cardiac Resynchronisation Therapy
NCT00376116 ·Status: COMPLETED
-
DISCOVERY: Diagnostic Data and Genetic Polymorphisms in ICD Patients.
NCT00478933 ·Status: COMPLETED ·Phase: NA
-
Wireless Stimulation Endocardially for Cardiac Resynchronization Therapy
NCT01294527 ·Status: COMPLETED ·Phase: NA