Eversense® Non-adjunctive Use Post Approval Study
NCT04836546 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 925
Last updated 2025-08-13
Summary
This is a non-blinded, prospective, multi-center, single arm longitudinal cohort study (patient serving as their own control), to evaluate the effectiveness of diabetes with the Eversense CGM System non-adjunctively compared to self-monitoring of blood glucose (SMBG) using a blood glucose (BG) meter in participants with either Type 1 or Type 2 diabetes. Subjects will serve as their own control, with their baseline based on using SMBG to manage their diabetes for the first 6 months followed by using Eversense CGM System non-adjunctively for the second 6 months. Total follow-up duration is 12 months. The investigation will include both clinic visits and home use of Eversense CGM System. The nonadjunctive phase will have two sensors, up to 90-day duration, inserted sequentially. All care decisions specific to diabetes will be based on blood glucose (BG) values in the first phase and the Eversense CGM system values in the second phase.
Conditions
Interventions
- DEVICE
-
Blood glucose meter
First phase: SMBG for 6 months
- DEVICE
-
Eversense CGM System
Second phase: CGM for 6 months
Sponsors & Collaborators
-
Senseonics, Inc.
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-04-13
- Primary Completion
- 2026-03-31
- Completion
- 2026-03-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Effectiveness and Safety Study of the Abbott Sensor Based Glucose Monitoring Systems
NCT02283411 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Eversense Continuous Glucose Monitoring System in Type I Diabetic Youth
NCT03815552 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Safety and Effectiveness of the Dexcom Glucose Monitoring (CGM) System
NCT04645641 ·Status: UNKNOWN ·Phase: NA
-
Observational Study to Evaluate the Effectiveness and Safety Study of the Dexcom G4™ Continuous Glucose Monitoring System
NCT01514305 ·Status: COMPLETED
-
Effectiveness and Safety of the RIGHTEST Continuous Glucose Monitoring System for Blood Glucose Management in Persons With Diabetes Mellitus
NCT04838392 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Continuous Glucose Monitoring in Hospitalized Patients With Diabetes Mellitus
NCT04653454 ·Status: COMPLETED ·Phase: NA
-
Continuous Monitoring and Control of Hypoglycemia
NCT03340831 ·Status: UNKNOWN
-
Continuous Glucose Monitors to Regulate Glucose Levels in Type 2 Diabetics
NCT03252964 ·Status: COMPLETED ·Phase: NA
-
Self-Monitoring of Blood Glucose Study#1: The Ability of People With Diabetes to Use OneTouch(R) Ultrasmart(tm)
NCT00333853 ·Status: COMPLETED ·Phase: NA
-
Continuous Glucose Monitoring in Patients With Type 2 Diabetes
NCT00529815 ·Status: UNKNOWN ·Phase: PHASE4
-
An Evaluation of a Novel Glucose Sensing Technology in Type 2 Diabetes
NCT02082184 ·Status: COMPLETED ·Phase: NA
-
PROMISE Study: An Evaluation of an Implantable Continuous Glucose Sensor up to 180 Days
NCT03808376 ·Status: COMPLETED ·Phase: NA
-
A Study of the Continuous Glucose Monitoring System for Home Use in Patients With Diabetes
NCT04964752 ·Status: UNKNOWN ·Phase: NA
-
Develop Novel Methods to Display, Report and Analyze CGM Data for Clinical Decision-Making in People With Diabetes
NCT00465881 ·Status: COMPLETED
-
A Clinical Study to Evaluate the Use of Episodic, Intensive Blood Glucose Monitoring in Persons With Non-insulin Treated Type 2 Diabetes
NCT00674986 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Updated Continuous Glucose Monitoring (CGM) Form Factor in Adults, Adolescents and Pediatrics
NCT04436822 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of CGMS Vs. Self-monitoring Blood Glucose (SMBG) in Woman with Gestational Diabetes
NCT04948112 ·Status: COMPLETED ·Phase: NA
-
A Study on the Effect of CGM Alone on Glycemic Metrics in Type 2 Diabetes Patients Not Using Insulin, Without Additional Interventions
NCT07298850 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of the Accuracy of an Implanted Glucose Sensor
NCT02647905 ·Status: COMPLETED ·Phase: NA
-
The Management of Glucose Control and Hypoglycemic Prevention Using Continuous Glucose Monitoring System in Patients With Type 1 Diabetes
NCT04684030 ·Status: UNKNOWN ·Phase: NA
-
Continuous Glucose Monitors to Regulate Glucose Levels in Type 2 Diabetics - (Protocol 3)
NCT03290768 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Accuracy of the Abbott Sensor Based Interstitial Glucose Monitoring System
NCT02073058 ·Status: COMPLETED
-
Blood Monitoring and Data Acquisition and Utilization in Patients With Type 2 Diabetes Treated With Insulin
NCT01175408 ·Status: COMPLETED ·Phase: NA
-
PRECISE: A Prospective, Multi-Center Evaluation of the Accuracy of a Novel Continuous Implanted Glucose Sensor
NCT02154126 ·Status: COMPLETED ·Phase: NA
-
Effectiveness and Safety Study of the Dexcom G4™ Continuous Glucose Monitoring System
NCT01514292 ·Status: COMPLETED ·Phase: NA