Dielectric Properties of Matched Tissue Samples From Thoracic Malignancies and Corresponding Normal Tissues
NCT04804410 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2021-03-18
Summary
The purpose of the Dielectrics Properties of Thoracic Malignancies Study (DPTMS) is to provide a wealth of knowledge for investigators involved in establishing a new and effective treatment for a variety of solid tumors using tumor treatment fields. It is intended to provide biospecimen (tumor/healthy) together with demographic data (age, sex, race, occupational history, and other epidemiologic information), and clinical data (stage, treatment, survival information, and annotated CT's). Our specific aims are to test the following hypotheses: 1) Electric properties of thoracic tumors differ from electric properties of surrounding healthy tissue 2) Different tumor types will have different electric properties 3) Electric properties of individual tumors are heterogeneous 4) Electric properties of tumors are related to the structure and composition of the underlying tissue 5) Use of standard medical imaging data (CT) will permit mapping of electric properties.
Conditions
- Lung Cancer
- Esophageal Cancer
- Mesothelioma; Lung
Interventions
- DEVICE
-
LCR Meter (Brand: Keysight, Serial Number:E498AL)
The LCR meter is used for electric property analysis of tissues. It works by measuring impedance on multiple sections of excised tissue and translating those measurement into dielectric properties.
Sponsors & Collaborators
-
NovoCure Ltd.
collaborator INDUSTRY -
University of Maryland, Baltimore
lead OTHER
Principal Investigators
-
Joseph Friedberg, MD, FACS · University of Maryland, Baltimore
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-03-31
- Primary Completion
- 2021-09-30
- Completion
- 2021-12-31
More Related Trials
-
Tissue Procurement and Natural History Study of People With Non-Small Cell Lung Cancer, Small Cell Lung Cancer, Extrapulmonary Small Cell Cancer, Pulmonary Neuroendocrine Tumors, and Thymic Epithelial Tumors
NCT02146170 ·Status: RECRUITING
-
Feasibility Study of Radiation Therapy With Wide Detector 4DCT Scanning for Primary or Metastatic Lung Cancer
NCT06233396 ·Status: COMPLETED
-
Application of DCE-MRI Based on 4D FreeBreathing in Predicting the Efficacy of Immune and Targeted Therapy in Lung Cancer
NCT06742021 ·Status: RECRUITING ·Phase: NA
-
Localization for Deep Lung Nodules: Microcoil Versus Contrast Injection
NCT03617029 ·Status: UNKNOWN ·Phase: NA
-
Developing Novel Circulating Epigenetic Biomarkers for Early Detection of Lung Cancer
NCT04814407 ·Status: RECRUITING
-
Bronchoscopic Microwave Ablation of Lung Tissue
NCT05786625 ·Status: ACTIVE_NOT_RECRUITING
-
Clinical Study for Combined Analysis of CTC and Exosomes on Predicting the Efficacy of Immunotherapy in Patients With Hepatocellular Carcinoma
NCT05575622 ·Status: UNKNOWN
-
Construction and Evaluation of the Liquid Biopsy-based Early Diagnostic Model for Lung Cancer
NCT04156360 ·Status: UNKNOWN
-
WHENII - Early Response Evaluation With FDG-PET/CT and Liquid Biopsy in Patients With NSCLC
NCT03481101 ·Status: UNKNOWN ·Phase: NA
-
Feasibility Study of Enhanced MRI for Early Stage Non Small Cell Lung Cancer (NSCLC)
NCT01799135 ·Status: TERMINATED ·Phase: NA
-
Liquid Biopsy in Lung Cancer
NCT03479099 ·Status: COMPLETED
-
An Exploratory Study of ctDNA-MRD in Predicting the Efficacy of Esophageal Squamous Cell Carcinoma
NCT05759325 ·Status: NOT_YET_RECRUITING
-
Enumeration of Circulating Tumour Cells (CTCs) in Patients With Advanced Solid Malignancy Using Complementary Metal Oxide Semiconductor (CMOS) Technology
NCT01596452 ·Status: UNKNOWN
-
Non-linear Multimodal Microendoscopy for Lung Cancer Pathology
NCT02699229 ·Status: WITHDRAWN
-
Application of Diffusion Weighted MRI Versus CT in Evaluation of the Effect of Treating Lung Cancer
NCT02320617 ·Status: UNKNOWN ·Phase: NA
-
Proton Therapy to Reduce Acute Normal Tissue Toxicity in Locally Advanced Non-small-cell Lung Cancer
NCT02731001 ·Status: RECRUITING ·Phase: NA
-
The Feasibility of Dynamic Liquid Biopsy Monitoring During Neoadjuvant Treatment for EGFR-mutated NSCLC
NCT06287593 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Retrospective Multicenter Review to Evaluate the Performance of the Ion Endoluminal System in Sampling Pulmonary Lesions
NCT05160571 ·Status: COMPLETED
-
Liquid Biopsy Using Methylation Sequencing for Lung Cancer
NCT04253509 ·Status: COMPLETED
-
Low-dose Computed Tomography-guided Core Needle Biopsy for Lung Nodules
NCT04217655 ·Status: COMPLETED ·Phase: NA
-
Low-dose Protocol for Computed Tomography-guided Lung Biopsy
NCT02971176 ·Status: COMPLETED ·Phase: NA
-
Study on the Diagnosis of Ground-glass Lung Cancer by Microwave Ablation Combined With Puncture Biopsy
NCT06776588 ·Status: RECRUITING ·Phase: NA
-
Study of Tissue Samples From Patients With Non-Small Cell Lung Cancer
NCT01414595 ·Status: COMPLETED
-
Construction and Use of Lung Tumor Microarray for the Analysis of Gene Expression in Lung Cancer
NCT00340847 ·Status: COMPLETED
-
Differentiating the Invasiveness of Lung Adenocarcinoma by Dual Energy CT Parameter
NCT06441357 ·Status: RECRUITING