Spectral Analysis of Central Venous Pressure Waveform
NCT04733547 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 60
Last updated 2023-12-19
Summary
The use of central venous pressure has been abandoned for the assessment of intravascular volume status. The dynamic fluctuation of central venous pressure according to heart rate is quantitatively measured by spectral analysis of the central venous pressure waveform. Its clinical utility in the assessment of intravascular volume status is investigated.
Conditions
- Donor Hepatectomy
- Central Venous Catheter
- Hypovolemia
Interventions
- PROCEDURE
-
Placement of a central venous catheter
The right internal jugular vein is located at the first rib level under ultrasound-guidance. Using an out-of-plane technique, a needle is introduced into the lumen of the vessel. The aspiration of blood into the syringe connected to the hub of the needle confirms the placement of the needle tip in the lumen. After the syringe is detached from the needle, a guidewire is advanced into the vessel lumen through the needle. A dilator is introduced over the guidewire and subsequently is removed. Then, a central venous catheter is introduced over the guidewire into the vessel lumen through the pathway expanded by the dilator. The catheter tip is placed in the superior vena cava by inserting the catheter as far as the distance between the edge of the right transverse process of the first thoracic vertebra and the carina, which is preoperatively measured on a posteroanterior chest radiograph.
- DEVICE
-
Monitoring of central venous pressure
Following the placement of a central venous catheter, a fluid-filled system for monitoring central venous pressure is connected to the proximal lumen of the catheter. The reference transducer is placed at the level of 4/5 of the anteroposterior diameter of the thorax.
- DRUG
-
Furosemide-induced hypovolemia before graft procurement
Patients fast from 10 pm the day before surgery. On the arrival at the operating room, an intravenous catheter for Plasmalyte infusion is placed into the right cephalic or basilic vein. The distal lumen of the central venous catheter is used for the infusion of 6% hydroxyethyl starch. Fluid requirements due to anesthesia, surgery, and no per os intake are not replaced by minimizing the administration of the fluids. Five minutes after the collection of the baseline data, 20 mg of furosemide is administered to promote diuresis for facilitating the venous outflow of the liver. An additional dose of furosemide 20 mg is given if the urine output is \<1 ml/kg within 30 minutes after the first dose. Unless the second dose of furosemide produces \>1 ml/kg of urine within 30 minutes, 40 mg of furosemide is administered. In the absence of effective diuresis (1 ml/kg within 30 minutes after each dose), the use of furosemide is abandoned and the patients are excluded from the study.
- DRUG
-
Replacement of fluid loss after graft procurement
Immediately after the graft procurement, 500 ml of 6% hydroxyethyl starch are infused over 25 minutes. Afterward, Plasmalyte is infused at a rate of 10 ml/min until the end of surgery.
- DEVICE
-
Monitoring of stroke volume variation
Following anesthesia induction, the right radial artery is catheterized. The catheter is connected to the EV1000 monitor (Edwards Lifesciences, Irvine, CA) through the FloTrac transducer (Edwards Lifesciences). The transducer is level with the one for central venous pressure monitoring. Using pulse contour analysis without external calibration, the stroke volume for each heartbeat is measured. At a 20-second interval, stroke volume variation is calculated as (maximum stroke volume - minimum stroke volume)/mean stroke volume.
Sponsors & Collaborators
-
JongHae Kim
lead OTHER
Principal Investigators
-
Jonghae Kim, M.D. · Daegu Catholic University Medical Center
Eligibility
- Min Age
- 20 Years
- Max Age
- 60 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-02-22
- Primary Completion
- 2023-11-29
- Completion
- 2023-11-29
Countries
- South Korea
Study Locations
More Related Trials
-
The Relationship Between Cardiac Output and Microvascular Visceral Blood Flow
NCT02167178 ·Status: COMPLETED
-
Peripheral Venous Pressure as an Indicator of Central Venous Pressure in Post Operative Surgical Patients: A Randomised Controlled Trial
NCT05476666 ·Status: COMPLETED ·Phase: NA
-
Respiratory Variation of Carotid Doppler Peak Velocity (CDPV) for Non-invasive Prediction of Fluid Responsiveness
NCT05185141 ·Status: RECRUITING
-
Ultrasonic Measurement of IVC and IJV in Predicting Hypotension After Anesthesia Induction
NCT04379141 ·Status: UNKNOWN
-
Stroke Volume Variation and Pulse Pressure Variation as Predictors of Fluid Responsiveness During Kidney Transplantation
NCT02459470 ·Status: COMPLETED ·Phase: NA
-
Hypotension Prediction Index in Living Donor Liver Transplantation
NCT05010941 ·Status: COMPLETED
-
Haemodynamical Optimization During Brain Surgery
NCT04114799 ·Status: RECRUITING ·Phase: NA
-
Point Of Care Ultrasound For Prediction Of Fluid Responsiveness in Off Pump Coronary Artery Bypass Grafting Surgery
NCT05968040 ·Status: UNKNOWN ·Phase: NA
-
Predictive Value of Intraoperative Indocyanine Green Clearance Test After Partially Blood Flow Blocking in Postoperative Liver Reserve
NCT03654183 ·Status: UNKNOWN
-
The Effect of Remote Ischemic Postconditioning on Postoperative Renal Dysfunction in Patients Undergoing Valvular Heart Surgery
NCT02720549 ·Status: COMPLETED ·Phase: NA
-
The Validity of Central Venous to Arterial Co2 Difference During Living Donor Liver Transplantation
NCT03123172 ·Status: COMPLETED ·Phase: NA
-
Pressure Gradient for Venous Return in Predicting Fluid Responsiveness in Patients Undergoing Laparoscopic Surgery
NCT04030221 ·Status: UNKNOWN
-
Non-invasive Prediction of Fluid and Noradrenaline Responsiveness Using the Carotid Wave Intensity.
NCT06197321 ·Status: COMPLETED
-
Effect of Wide Pulse Pressure on the Predictability of Stroke Volume Variation for Fluid Responsiveness in Patients Undergoing Off-pump Coronary Artery Bypass Graft
NCT01404455 ·Status: COMPLETED ·Phase: NA
-
Ultrasound of the Inferior Vena Cava in the Prevention of Hypotension After Induction of General Anesthesia
NCT06530901 ·Status: NOT_YET_RECRUITING
-
Femoral Venous Pulsatility and Right Heart Dysfunction in Heart Surgery: An Observational Study
NCT05038267 ·Status: COMPLETED
-
Hemodynamic Indices Predictive of a Beneficial Response to Fluid Expansion in Case of Hemodynamic Failure After Cardiac Surgery With Altered Preoperative Ejection Fraction (LVEF≤45%)
NCT01673230 ·Status: COMPLETED ·Phase: NA
-
Fluid Challenges and Microcirculation
NCT04559178 ·Status: TERMINATED
-
Prediction of Fluid Responsiveness in Atrial Fibrillation Patients Who Underwent Valvular Heart Surgery: Peep-induced Increase in Central Venous Pressure vs. Passive Leg Raising
NCT02224378 ·Status: COMPLETED ·Phase: NA
-
Assessments of Dynamic Variables of Fluid Responsiveness to Predict Desufflation-induced Hypotension in Urologic Patients Undergoing Laparoscopic Surgery
NCT03967119 ·Status: UNKNOWN
-
Intraoperative Fluid Management Guided by Internal Jugular Vein on Postoperative Complications in Abdominal Surgeries
NCT07041021 ·Status: RECRUITING ·Phase: NA
-
The Influence of Pneumoperitoneum on Minimal Invasive Cardiac Output Measurements
NCT01854307 ·Status: TERMINATED ·Phase: NA
-
Femoral Vein Diameter to Predict Intraoperative Hypotension in Geriatric Patients Undergoing Orthopedic Surgery Under Spinal Anesthesia
NCT07339475 ·Status: RECRUITING
-
Non-invasive Assessment of Arterial Blood Pressure and Functional Hemodynamic Parameters
NCT01292759 ·Status: UNKNOWN
-
Comparison of Cardiac Output Measurement Between Transpulmonary Thermodilution and Photoplethysmography
NCT01535703 ·Status: COMPLETED