Point Of Care Ultrasound For Prediction Of Fluid Responsiveness in Off Pump Coronary Artery Bypass Grafting Surgery

NCT05968040 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40

Last updated 2023-08-01

No results posted yet for this study

Summary

To exclude hypovolemia before starting off pump coronary artery grafting surgeries by an efficient and good predictive test. We will assess the sensitivity and specificity of dynamic IVC-derived parameters (dispensability index) in comparison to carotid Doppler peak velocity as predictors of fluid response before skin incision in patients undergoing off Pump cardiac surgery.

Conditions

  • Prevention of Hypotension

Interventions

PROCEDURE

Inferior vena cava diameter measurement by ultrasonography

The diameter of the inferior vena cava will be measured at 2 cm close to the entrance of the right atrium. Ultrasound images will be taken at the end of inspiration (Dmax) and at the end expiration (Dmin) to calculate the inferior vena cava dispensability index (dIVC), and will be recorded before and after fluid challenge test of 5 ml/kg crystalloid within 15 min. The IVC distensibility index (IVC-DI) will be calculated using the formula: IVC-DI = IVCmax - IVCmin/ IVCmin. The indices will be expressed as a percentage.

PROCEDURE

difference between peak velocities of carotid artery by ultrasound

Carotid ultrasound images will be obtained from the left CCA in both short-axis and long-axis views by experienced sonographers. The patient will be in supine position, with the head rotated slightly to the right. A broadband linear array transducer 12-4 MHz and the short-axis view will be used for orientation and identification of the CCA. Next, in the long-axis view, Peak Waveform Doppler signals will be acquired by placing a 0.5 mm calliper at the center of the vessel and parallel to the vessel walls, approximately 2 cm proximal from the carotid bifurcation. Insonation-angles between the ultrasound beam and blood flow will be maintained. ΔVpeakCCA = (MaxCDPV-MinCDPV)+(MaxCDPV+MinCDPV)x100

PROCEDURE

cardiac output be transthoracic echocardiography

CO will be recorded as baseline measure and after fluid administration. If CO increased more than 15%, it will be considered fluid responder. Increase in cardiac output = (cardiac output after first fluid challenge - cardiac output before)/cardiac output before) X 100. TTE will be used to measure LTOT and VTI x HR.

Sponsors & Collaborators

  • Ain Shams University

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
QUADRUPLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
60 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2023-08-01
Primary Completion
2024-06-01
Completion
2024-06-30

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05968040 on ClinicalTrials.gov