Reliability of Myotonometry in Swimming Athletes
NCT04697433 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 48
Last updated 2021-01-06
Summary
The clinical analysis of athletes has been performed in the sports field to obtain parameters for reliable evaluations. Among the tools used is the myotonometry, an analysis capable of quantitatively measuring tone, stiffness and elasticity. Its reliability has been tested in several populations, however, showing changes in results and presenting high variability in the confidence interval, also, the values of myotonometry differ according to sample specificity and the biomechanical properties of each muscle. Therefore, it seems pertinent to perform the reliability analysis in swimming athletes and verify their applicability and if the values of tone and muscular biomechanical properties vary according to the specificity of the modality. It will be a test and retest study composed of 50 young male and female swimming athletes, aged between 12 and 20 years. The evaluation of myotonometry will be performed randomly by two evaluators and the parameters measured will be: tone, stiffness, elasticity, relaxation time of mechanical stress and displacement. In the test stage, the first evaluator will perform the measurements bilaterally on the muscles and the second evaluator will perform the same measurements in the same order immediately after the first one. After 15 minutes, the retest will be performed following the same order of evaluators in the test. For characterization of sample will be used descriptive statistic through central tendency and variability for all variables collected. Relative reliability will be tested by the Intraclass Correlation Coefficient (ICC). Absolute reliability will be verified by means of standard error of measurement (SEM), values of least detectable change (MMD) and coefficient of variation (CV). The statistical package SPSS Statistics 22.0 will be used to conduct the reliability analyses.
Conditions
- Athletes
Interventions
- DEVICE
-
Myotonometry
The examiner should exert a slight pressure on the determined point to the necessary depth, which will be indicated by changing the color from red to green light on the device. The device has an automatically controlled preload (0.18 Newton (N)) that will be applied to the contact area by an automatic mechanical pulse, with a duration of 15 milliseconds (ms) and a constant force of 0.4 N , these oscillations will be registered by an accelerometer next to the measurement mechanism inside the device. For each evaluation, a series of 10 consecutive pulses (multiscan mode) will be used with an interval of one second between each pulse. In each shot, the tone, stiffness, elasticity, relaxation time and creep will be calculated.
Sponsors & Collaborators
-
São Paulo State University
lead OTHER
Eligibility
- Min Age
- 12 Years
- Max Age
- 20 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2020-02-03
- Primary Completion
- 2020-03-16
- Completion
- 2020-03-16
Countries
- Brazil
Study Locations
More Related Trials
-
Reliability of a Endurance and a Strength Test for Shoulder Rotation
NCT03923608 ·Status: COMPLETED
-
Reliability of Myotonometry in the Assessment of Mechanical Properties of Thenar Muscles
NCT06004635 ·Status: COMPLETED
-
Kinematical and Muscular Fatigue in Swimmers
NCT06069440 ·Status: COMPLETED ·Phase: NA
-
Neurophysiological Evaluation of Muscle Tone
NCT05070780 ·Status: UNKNOWN
-
Reliability and Validation of New Manual Dynamometer to Measure Lower Limb Strength
NCT05573139 ·Status: COMPLETED ·Phase: NA
-
Electromyographic (EMG) and Mechanomyographic (MMG) Comparison
NCT00942370 ·Status: COMPLETED
-
Abdominal Electromyographic Control in Vojta Therapy
NCT04818879 ·Status: COMPLETED ·Phase: NA
-
Training-induced Muscle Strength and Its Role in Interface Pressure in Inelastic Compression
NCT05023642 ·Status: COMPLETED ·Phase: NA
-
Exercises Directed To Dynamic Stiffness Of The Thoracolumbar Region And Performance Of Amateur Runners
NCT05760664 ·Status: RECRUITING ·Phase: NA
-
Inspiratory and Trunk Muscle Activity During IMT on Stable and Unstable Surfaces in Stroke Patients
NCT06877338 ·Status: NOT_YET_RECRUITING
-
Respiratory Muscles Electromyography in Patients With Covid-19
NCT05572853 ·Status: COMPLETED
-
Normative Values for Peripheral Muscle Strength in Critical Patients and Healthy Individuals
NCT06296381 ·Status: RECRUITING
-
Respiratory Muscle Stretching Effect on Functional and Electromyographic Parameters of Patients With and Without COPD
NCT03417908 ·Status: UNKNOWN ·Phase: NA
-
The Relationship Between Muscle Morphology and Muscle Strength
NCT00933192 ·Status: COMPLETED
-
Inspiratory Muscle Training and Neuromuscular Electrical Stimulation in Chronic Obstructive Pulmonary Disease
NCT04387318 ·Status: COMPLETED ·Phase: NA
-
Abdominal Wall Evaluation in Low Back Pain
NCT01488760 ·Status: COMPLETED
-
Influence of an Inspiratory Muscle Fatigue Protocol on Healthy Youngs on Respiratory Muscle Strength, Vertical Jump Performance and Muscle Oxygen Saturation
NCT06271876 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Inspiratory Muscle Training on Diaphragm Thickness, Inspiratory Muscle Strength and Shoulder Pain in Tennis Player
NCT06186180 ·Status: COMPLETED ·Phase: NA
-
Electromyography During Common Exercises Used in Rehabilitation
NCT01400347 ·Status: WITHDRAWN
-
Biomechanical Relationship Between Trunk Flexion and Mouth Opening: Pilot Study
NCT06188897 ·Status: COMPLETED ·Phase: NA
-
The Influence of the Diaphragm Muscle and Pain Perception on Lower Limb Neuromuscular Control in Sports Practice.
NCT05982210 ·Status: UNKNOWN ·Phase: NA
-
Clinical Assessment and Thickness Changes of the Oblique and Multifidus Muscles
NCT03539211 ·Status: COMPLETED ·Phase: NA
-
The Effects of Inspiratory Muscle Training in Patients With Heart Failure and Obstructive Sleep Apnea Syndrome
NCT02794935 ·Status: UNKNOWN ·Phase: NA
-
Recording Methods of Muscle Activity "Onset".
NCT00184535 ·Status: COMPLETED
-
Neural Adaptations to Metronome-Paced Strength Training
NCT06532786 ·Status: RECRUITING ·Phase: NA