Starling Registry Study
NCT04648293 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 1207
Last updated 2024-04-16
Summary
Hemodynamic optimization of critically ill patients is a goal for clinicians in order to afford the patient the best possible outcomes. Being able to precisely and rapidly determine patient fluid responsiveness provides the bedside physician and nursing staff the information needed to make critical decisions in regards to the patient's fluid status and management of additional fluids and medications.
As fluid management and cardiac output determination are linked to better decision-making and improved outcomes in ICU, the use of a dynamic assessment of fluid responsiveness becomes a key tool for patient management.
This study is designed to collect treatment and outcome data on patients that have undergone hemodynamic monitoring in a wide variety of clinical settings, involving a variety of patient diagnoses.
Conditions
- Hemodynamic Monitoring
Interventions
- DEVICE
-
Starling
Starling is a portable, non-invasive, cardiac output detector system. The Starling monitor measures the cardiac output by employing electrical bioreactance that measures the electrical characteristics of a volume of tissue and fluid. In the case of cardiac output measurements, the relevant tissue includes the heart and the immediate surrounding volume of the thorax. The relevant fluid is blood. Baxter Healthcare's Starling electrode is a double electrode sensor. Within each sensor, one electrode is used to transmit a high frequency sine wave into the body, while the resulting voltage is measured at the adjacent electrode. Four electrodes are placed at specific areas of the thorax, the impedance to the current flow calculated, and the electrical bioreactance waveform constructed. This information is used to determine cardiac output, and measures and displays associated hemodynamic parameters based on calculations of measurements already incorporated into the Starling device.
Sponsors & Collaborators
-
Baxter Healthcare Corporation
lead INDUSTRY
Principal Investigators
-
Caio Plopper, MD · Baxter Healthcare
Eligibility
- Min Age
- 18 Years
- Max Age
- 95 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-11-16
- Primary Completion
- 2024-02-21
- Completion
- 2024-02-21
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Stratification of the Acute Respiratory Distress Syndrome - A Second Phase Study
NCT02836444 ·Status: COMPLETED
-
Ultrasound Measurement of Reactive Hyperemia in Critical Care
NCT01726595 ·Status: COMPLETED
-
Diuretic Tuner Clinical Decision Support
NCT04759274 ·Status: RECRUITING ·Phase: NA
-
Hospital-wide Incidence, Clinical Characteristics and Outcomes of ARDS
NCT03546699 ·Status: UNKNOWN
-
Arterial Pressure Derived Dynamic Parameters to Detect Preload Responsiveness in Spontaneously Breathing Patients
NCT06480942 ·Status: COMPLETED
-
The Role of Lung and Diaphragm Ultrasonography in Predicting Clinical Progression in Hypoxemic Respiratory Failure
NCT06706830 ·Status: COMPLETED
-
Detection of Right Ventricular Dysfunction by 2D Strain During Acute Respiratory Distress Syndrom (ARDS)
NCT01757522 ·Status: COMPLETED
-
Lung Ultrasound-Guided Fluid Deresuscitation in ICU Patients
NCT05188092 ·Status: RECRUITING ·Phase: NA
-
Speckle Tracking and Inhaled Nitric Oxide in Acute Respiratory Distress Syndrome
NCT05104606 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Decision-making - the Benefit of Bedside CRP Within Ambulance Care
NCT04097210 ·Status: COMPLETED
-
B-lines Lung Ultrasound Guided ED Management of Acute Heart Failure Pilot Trial
NCT03136198 ·Status: COMPLETED ·Phase: PHASE2
-
Assessment of Cardiac Output in Patients With ARDS Implanted With Venous-venous ECMO.
NCT05164484 ·Status: UNKNOWN ·Phase: NA
-
Carotid Doppler Ultrasound for the Measurement of Intravascular Volume Status
NCT02907931 ·Status: COMPLETED ·Phase: NA
-
Assessing Outcomes in ED Patients With RV Failure
NCT03073629 ·Status: TERMINATED ·Phase: NA
-
Extra Vascular Lung Water and Pulmonary Permeability in Critically Ill Patients With SARS-CoV-2 (COVID-19)
NCT04376905 ·Status: COMPLETED
-
Evaluation of Pupillary Distension Reflexes, as a Tool for the Monitoring of Analgesia for Patients in Intensive Care.
NCT02843893 ·Status: COMPLETED ·Phase: NA
-
Cerebrovascular Hemodynamics in Patients With ARDS.
NCT03949738 ·Status: COMPLETED
-
Functional Respiratory Imaging of Airways in ARDS
NCT03309085 ·Status: COMPLETED ·Phase: NA
-
Effect of Positive Expiratory Pressure on Right Ventricular Function in Patients With Respiratory Distress Syndrome
NCT00236262 ·Status: COMPLETED ·Phase: NA
-
Assessment of Fluid Responsiveness by Elevation of PEEP in Patients With Septic Shock
NCT01827007 ·Status: COMPLETED ·Phase: NA
-
Assessment of Pulmonary Congestion During Cardiac Hemodynamic Stress Testing
NCT04019613 ·Status: TERMINATED ·Phase: NA
-
The Regulation of Pulmonary Vascular Resistance in Patients With Heart Failure
NCT02275793 ·Status: COMPLETED
-
Personalized Mechanical Ventilation Guided by UltraSound in Patients With Acute Respiratory Distress Syndrome
NCT05492344 ·Status: RECRUITING ·Phase: NA
-
Volume Responsiveness By Ultrasound Of Carotid Blood Flow In Patients With Cardiogenic Shock
NCT05271227 ·Status: COMPLETED
-
Clinical Study of VA-ECMO Remote Limb Re-perfusion Monitoring Technology
NCT04929873 ·Status: UNKNOWN ·Phase: NA