Monitoring Local Tissue Oxygen Changes Using the Wireless Lumee Oxygen Platform in Correlation to TcPO2
NCT04514861 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 53
Last updated 2025-11-12
Summary
The purpose of this study is to monitor changes in local tissue oxygen levels in participants with Peripheral Artery Disease (PAD) using the Wireless Lumee Oxygen Platform. A transcutaneous oxygen pressure (TcPO2) device is used to show correlations in oxygen dynamics. Oxygen dynamics are induced by a pressure cuff and position maneuvers. Study participants will participate in the study for 12 months with six (6) planned visits over the course of the study.
The investigational device, the Wireless Lumee Oxygen Platform, consists of the Lumee Oxygen, a sterile soft injectable oxygen-sensitive hydrogel, designed to sense and report oxygen levels in the subcutaneous tissue. After initial insertion of the hydrogel in the subcutaneous tissue using the Lumee Pen (a sterile disposable injector device), tissue oxygen levels can be monitored continuously using the Lumee Patch (a non-invasive, non-sterile, wireless electronic device to collect, analyze and report tissue oxygen levels sensed by Lumee Oxygen Hydrogel) attached to the skin through the Lumee Patch Adhesive (designed to adhere the Lumee Patch). The Lumee Patch sends collected tissue oxygen data to the Lumee App which displays the collected data and operates up to four Lumee Patches.
Conditions
Interventions
- DEVICE
-
Wireless Lumee Oxygen Platform
The Lumee Oxygen Platform is designed to monitor oxygen dynamics with a hydrogel placed in subcutaneous tissue
Sponsors & Collaborators
-
National Institutes of Health (NIH)
collaborator NIH -
National Heart, Lung, and Blood Institute (NHLBI)
collaborator NIH -
Profusa, Inc.
lead INDUSTRY
Principal Investigators
-
Monica M Lozano, PhD · Profusa, Inc.
Study Design
- Allocation
- NA
- Purpose
- BASIC_SCIENCE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-12-18
- Primary Completion
- 2027-03-30
- Completion
- 2028-03-30
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Noninvasive Determination of Cerebral Tissue Oxygenation in Pulmonary Hypertension
NCT01463514 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Noninvasive Pulse Oximeter Sensor (MightySat RX)
NCT03125135 ·Status: COMPLETED ·Phase: NA
-
Validation of Respiration Rate Algorithms
NCT01472133 ·Status: COMPLETED
-
Accuracy Validation of a Pulse Oximetry Monitor
NCT02506010 ·Status: WITHDRAWN
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT05139693 ·Status: COMPLETED
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT02571686 ·Status: COMPLETED
-
Needle Free Assessment of Myocardial Oxygenation in Healthy Subjects
NCT06000540 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Pulse Oximeter Hypoxia
NCT04562584 ·Status: COMPLETED ·Phase: NA
-
Transcutaneous Monitoring of Oxygen and Carbon Dioxide in Surgical Patients
NCT04040478 ·Status: COMPLETED
-
Pulse Oximeter Accuracy in Healthy Humans During Hypoxia
NCT06142019 ·Status: RECRUITING
-
SpO2 Accuracy of Noninvasive Disposable Pulse Oximeter Sensor With Motion Conditions
NCT05264116 ·Status: COMPLETED ·Phase: NA
-
Pulse Contour Analysis and Tissue Oxymetry in Changing Vascular Tone
NCT00583687 ·Status: COMPLETED ·Phase: NA
-
SpO2 Accuracy Low Saturation Validation of the OxySoftN Sensor
NCT04811963 ·Status: COMPLETED
-
Pulse Oximeter Motion Study
NCT03156140 ·Status: COMPLETED ·Phase: NA
-
FloPatch for Prevention of Hypotension After Induction of General Anesthesia
NCT06316817 ·Status: COMPLETED
-
Accuracy of Pulse Oximeters With Profound Hypoxia
NCT04324385 ·Status: COMPLETED
-
The Effect of Continuous Pulse Oximetry Monitoring and Early Intervention Using Wearable Device on the Incidence of Postoperative Hypoxemia
NCT04694599 ·Status: UNKNOWN ·Phase: NA
-
SpO2 Accuracy of Noninvasive Pulse Oximeter Sensor
NCT05141500 ·Status: COMPLETED ·Phase: NA
-
Perceptual, Hemodynamic and Cardiovascular Responses of Two Different BFR Training Protocols
NCT05145335 ·Status: COMPLETED ·Phase: NA
-
Pulse Oximeter Accuracy During Stable Hypoxia Plateaus
NCT06460246 ·Status: COMPLETED ·Phase: NA
-
Apneic Oxygenation Via Nasal Cannulae Prevents Arterial Hypoxemia
NCT00782977 ·Status: COMPLETED ·Phase: NA
-
Ambulatory Measurements of Physiological Parameters
NCT01267513 ·Status: UNKNOWN
-
Pulse Oximetry_Performance During Severe Signal Interference - PCBA-1 (Printed Circuit Board Assembly)
NCT01747473 ·Status: COMPLETED
-
Determination of the Accuracy of a Non-Invasive Continuous Blood Pressure Device
NCT01311128 ·Status: TERMINATED
-
Accuracy of Noninvasive Pulse Oximeter Sensor (Rainbow DCI)
NCT03124823 ·Status: COMPLETED ·Phase: NA