Electronic Stethoscope Use During Intubation in Full Personal Protective Equipment
NCT04507958 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 50
Last updated 2021-06-08
Summary
To investigate the feasibility of auscultation to confirm the endotracheal tube position by using electronic stethoscope for clinicians who wear the full personal protective equipment.
Conditions
- Thoracic Surgery
Interventions
- DIAGNOSTIC_TEST
-
auscultation by using conventional stethoscope without PPE
In thoracic patients undergoing general anesthesia with endotracheal tube/endobronchial blocker, Clinician will check the position of endotracheal tube and endobronchial blocker under fiberscope. Afterward, investigator A will perform auscultation with traditional auscultation, then investigator B with electronic stethoscope under full PPE, to examine bilateral breathing sound.
- DIAGNOSTIC_TEST
-
auscultation by using electronic stethoscope in full PPE
In thoracic patients undergoing general anesthesia with endotracheal tube/endobronchial blocker, Clinician will check the position of endotracheal tube and endobronchial blocker under fiberscope. Afterward, investigator A will perform auscultation with traditional auscultation, then investigator B with electronic stethoscope under full PPE, to examine bilateral breathing sound.
Sponsors & Collaborators
-
National Taiwan University Hospital
lead OTHER
Principal Investigators
-
Chun-Yu Wu, PhD · National Taiwan University Hospital
Eligibility
- Min Age
- 20 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-09-16
- Primary Completion
- 2021-05-11
- Completion
- 2021-05-11
Countries
- Taiwan
Study Locations
More Related Trials
-
Comparison of Heart Rate Variability Among Tracheal Intubation Methods
NCT00778219 ·Status: COMPLETED
-
Tracheal Tube Cuff Shape and Pressure
NCT04591769 ·Status: COMPLETED ·Phase: NA
-
Assessment of a Properly Video Stylet Angulation for Nasotracheal Intubation
NCT04749225 ·Status: UNKNOWN
-
"Neutral Head Position" and "Head-lift Position" for Orotracheal Intubation With "Trachway" Intubating Stylet in Adults
NCT02578992 ·Status: COMPLETED ·Phase: NA
-
The Use of "O" Shaped- Endotracheal Tube During Intubation for General Anesthesia: Prospective Randomized Trial
NCT04520581 ·Status: UNKNOWN ·Phase: NA
-
Utility of Tracheal Ultrasonography for the Confirmation of the Endotracheal Tube Placement
NCT03220698 ·Status: COMPLETED
-
The Effects of Flexible Intubating Stylet in the Accurate Placement of Double-lumen Endobronchial Tube
NCT02364622 ·Status: COMPLETED ·Phase: NA
-
The Effect of 'Sniffing Position & Nasal Tip Lifting' in Nasotracheal Intubation
NCT03102255 ·Status: COMPLETED ·Phase: NA
-
Compare a New Method and Formula as a Guide for the Intubation of a Left-sided Double-lumen Tube
NCT03545737 ·Status: COMPLETED
-
Comparison of Different Tools to Facilitate Nasotracheal Tube Placement Under Video-laryngoscope Use
NCT03086798 ·Status: COMPLETED ·Phase: NA
-
The Efficacy of Trachway (R) Intubating Stylet in the Insertion of the Double Lumen Endobronchial Tube
NCT01517204 ·Status: COMPLETED ·Phase: NA
-
Assessment of Tube Position According to the Changes of Neck Position Between Two Different Types of Nasotracheal Tubes
NCT04499222 ·Status: UNKNOWN ·Phase: NA
-
Observation of the Pressure Changes of the Endotracheal Tube Cuff in the Head and Neck Surgery Under General Anesthesia
NCT03938493 ·Status: COMPLETED
-
The Effect of Lidocaine on Smooth Emergence With Double Lumen Tube
NCT04455711 ·Status: UNKNOWN ·Phase: NA
-
Which is the Best Bedside Test to Detect Endobronchial Intubation?
NCT01232166 ·Status: COMPLETED ·Phase: NA
-
Technique Using Trachway to Safely Navigate Endotracheal Tube Through Nasal Cavity
NCT03097913 ·Status: COMPLETED
-
Assessment of a Properly Video Stylet Angulation for Orotracheal Intubation
NCT04735250 ·Status: UNKNOWN
-
Endotracheal Intubation Using Macintosh Laryngoscope, Glidescope, Airwayscope During Chest Compression With Adjustment Height of a Bed
NCT02074098 ·Status: COMPLETED ·Phase: NA
-
Video-stylet for Nasotracheal Intubation
NCT01917409 ·Status: UNKNOWN ·Phase: NA
-
Applying High Resolution Impedance Manometry for Perioperative Swallowing Changes in Older Patients Receiving Endotracheal Intubation or Supraglottic Airway Devices During Orthopedic Surgery
NCT05420428 ·Status: COMPLETED ·Phase: NA
-
Evaluation on the Proper Size of the Nasotracheal Tube and Depth in Nasotracheal Intubation: a Preliminary Study
NCT02876913 ·Status: COMPLETED
-
Placement of the Double-Lumen Tube Without Fiberoptic Bronchoscope Assistance
NCT02943928 ·Status: COMPLETED ·Phase: NA
-
Screening and Intervention of Postextubation Dysphagia
NCT03284892 ·Status: COMPLETED ·Phase: NA
-
The Cuff Pressure of an Endotracheal Tube After Supine-to-lateral Position Change
NCT02165319 ·Status: UNKNOWN ·Phase: NA
-
Endotracheal Tube (ETT) 180: Stylet-loaded Endotracheal Tube Rotation Before Insertion
NCT06231342 ·Status: RECRUITING ·Phase: NA