Can the Electronic Nose Smell COVID-19?

NCT04475562 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 219

Last updated 2020-07-17

No results posted yet for this study

Summary

Infection with SARS-CoV-2 causes Corona Virus Disease (COVID-19). The most standard diagnostic method is reverse transcription-polymerase chain reaction (RT-PCR) on a nasopharyngeal and/or an oropharyngeal swab. The high occurrence of false-negative results due to the non-presence of SARS-CoV-2 in the oropharyngeal environment renders this sampling method not ideal. Therefore, a new sampling device is desirable. This proof-of-principle study investigates the possibility to train machine-learning classifiers with an electronic nose (Aeonose) to differentiate between COVID-19 positive- and negative persons based on volatile organic compounds (VOCs) analysis.

Methods: between April and June 2020, participants were invited for breath analysis when a swab for RT-PCR was collected. If the RT-PCR resulted negative, presence of SARS-CoV-2 specific antibodies was checked to confirm the negative result. All participants breathed through the Aeonose for five minutes. This device contains metal-oxide sensors that change in conductivity upon reaction with VOCs in exhaled breath. These conductivity changes are input data for machine-learning and used for pattern recognition. The result is a value between -1 and +1, indicating the infection probability.

Conditions

  • SARS-CoV Infection
  • Covid19

Interventions

DEVICE

Aeonose

All participants breathed through the Aeonose for five minutes. This device contains metal-oxide sensors that change in conductivity upon reaction with VOCs in exhaled breath. These conductivity changes are input data for machine-learning and used for pattern recognition. A nose clip was placed on the nose of each participant to avoid entry of non-filtered air in the device. Before measuring, the Aeonose was flushed with room air, guided through a carbon filter as well. During each measurement, a video was displayed to distract the participant and to reduce the chance of hyperventilation. Failed breath tests were excluded from analysis; the reason for failure was documented. Four similar Aeonose devices were used for breath analysis. A full-measurement procedure required sixteen minutes.

Sponsors & Collaborators

  • Maastricht University Medical Center

    lead OTHER

Study Design

Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2020-04-06
Primary Completion
2020-05-06
Completion
2020-07-01

Countries

  • Netherlands

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04475562 on ClinicalTrials.gov