The Effect of Auricle Position on Tympanic Thermometry
NCT04463537 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 143
Last updated 2020-07-09
Summary
Objective: The aim of this study was to investigate the effect of auricle position on body temperature measurements made with tympanic membrane thermometer in adult patients.
Methods: The study was conducted with a quasi-experimental design with a pre-test and a post-test. A total of 143 patients who fit the inclusion criteria of the study were included in the sample. The research carried out between 1 November - 31 December 2016 in the emergency department. Body temperature measurements were carried out on the patients in the study firstly by not changing the position of the auricle and then repeated after a minute, this time by changing the position of the auricle.
Results: The difference between the measurement values found in two different positions was 0.31 0C, and the Bland Altman plot showed that the differences were distributed systematically around the value 0.31. The difference between the lengths of measurements performed on two separate positions was detected to be 1.08 second. During body temperature measurements performed through giving position to auricle, 59.2 % of the patients never felt discomfort.
Conclusions: It was found in the comparison of two positions that there was a significant difference between the tympanic membrane thermometer measurements made by positioning the auricle and those without positioning.
Conditions
- Body Temperature Changes
Interventions
- PROCEDURE
-
Body Temperature Measurements
measurements were carried out on the patients in the study firstly by not changing the position of the auricle. The duration was measured by stop watch and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale". The measurement was then repeated after a minute, this time by changing the position of the auricle. The duration was measured for this position and the results were recorded in the data form.
Sponsors & Collaborators
-
Ege University
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2016-11-01
- Primary Completion
- 2016-12-01
- Completion
- 2017-01-05
More Related Trials
-
Concordance Between 2 Means of Temperature Measure in Neutropenic Patients Hospitalized in Intensive Hematology Care Units
NCT04174053 ·Status: COMPLETED ·Phase: NA
-
Temperature Measurement Using a Non Invasive Device
NCT01584401 ·Status: UNKNOWN
-
Evaluation of the Tyto Thermometer When Used in Clinical Care Setting
NCT03452020 ·Status: UNKNOWN ·Phase: NA
-
Measurement of Core Temperatures During Therapeutic Hypothermia
NCT01292148 ·Status: COMPLETED
-
Temporal Artery Thermometer in Patient Transport: Reliability and Validity.
NCT03920943 ·Status: WITHDRAWN ·Phase: NA
-
Effectiveness of Heat Donation Through the Head or Torso on Mild Hypothermic Rewarming
NCT01603511 ·Status: COMPLETED ·Phase: NA
-
Investigation of the Accuracy of Temporal Artery Thermometers
NCT01817881 ·Status: COMPLETED
-
Temperature Skin Check After Cryotherapy Application
NCT01950026 ·Status: COMPLETED ·Phase: PHASE3
-
Clinical Accuracy and Reliability of Infrared Tympanic Thermometer in an Adult Emergency Department
NCT02937129 ·Status: COMPLETED
-
Research on Intraoperative Hypothermia Risk Prediction Model and Temperature Management Strategy for Elderly Patients During Surgery Based on Dynamic Incremental Training
NCT06676735 ·Status: COMPLETED ·Phase: NA
-
Analysis of the Effects on Human Tissues After Application of Therapeutic Modalities.
NCT03414346 ·Status: COMPLETED ·Phase: NA
-
Study on the Difference of Axilo-rectal Temperature in Appendicitis
NCT00674726 ·Status: WITHDRAWN
-
Effect of Kinesio Taping on Lumbar Muscle Temperature
NCT06760299 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Acute Health Effects of Low Temperature Exposure
NCT06076629 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Accuracy of Non-invasive Temperature Measurement in Deep Hypothermia
NCT02009059 ·Status: UNKNOWN
-
Heated Humidification System Breathing Circuit for Maintenance of Body Temperature in Pediatric Patients
NCT03896867 ·Status: COMPLETED ·Phase: NA
-
Study of Axillary Skin Temperature as a Marker of Ovulation
NCT01360684 ·Status: COMPLETED
-
Effect of Self-acupressure on Middle Ear Barotrauma Associated With Hyperbaric Oxygen Therapy
NCT04311437 ·Status: UNKNOWN ·Phase: NA
-
The Effect of Warmed Socks Developed as Wearable Technology on Hypothermia, Thermal Comfort Perception and Shivering
NCT06283771 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Continuos Body Temperature Monitoring
NCT06447337 ·Status: RECRUITING
-
This Study Assesses the Impact of Different Sheets on Body Temperature and Sleep
NCT03446820 ·Status: COMPLETED ·Phase: NA
-
Validation of the Measurement Accuracy of the Tcore Thermometer
NCT04489927 ·Status: TERMINATED
-
Handheld Infrared Thermometer to Evaluate Cellulitis
NCT03846635 ·Status: COMPLETED
-
Clinical Evaluation of the Care On Line Thermometer
NCT00544141 ·Status: UNKNOWN
-
Impact of ICE on Exercise Performance in the Heat
NCT04596618 ·Status: COMPLETED ·Phase: NA