Temporal Artery Thermometer in Patient Transport: Reliability and Validity.
NCT03920943 · Status: WITHDRAWN · Phase: NA · Type: INTERVENTIONAL
Last updated 2021-03-04
Summary
Evaluate the reliability and validity of temperature measurements using an existing, Health Canada-approved, non-invasive temporal artery thermometer, and comparing results to an established, invasive gold standard (esophageal probe), in order to assess reliability of this non-invasive method to measure core body temperature in the setting of patients undergoing inter-facility patient transport by land, rotor-wing, and fixed-wing transport vehicles.
Conditions
- Body Temperature
Interventions
- OTHER
-
Measurement of temperature using non-invasive means
The study intervention will involve paramedics using the TAT device to measure temperature non-invasively,the first measurements made at least 5 minutes after insertion of the temperature probe (control measurement #1), and also prior to departure from the sending facility (control measurement #2). Once the patient is in the transport vehicle and the vehicle in motion for at least 10 minutes, the paramedics will measure the patient's temperature non-invasively using the TAT. If the transport time exceeds 1 hour, additional measurements taken at 1 hour intervals for the duration of transport (up to a total of 8 hours).
Sponsors & Collaborators
-
Ornge Transport Medicine
lead OTHER
Principal Investigators
-
Fuad Alnaji, MD FRCPC · Ornge Transport Medicine
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-09-01
- Primary Completion
- 2020-12-31
- Completion
- 2021-06-30
Countries
- Canada
Study Locations
More Related Trials
-
Measurement of Core Temperatures During Therapeutic Hypothermia
NCT01292148 ·Status: COMPLETED
-
Accuracy and Precision Comparison of Temptraq
NCT03264833 ·Status: COMPLETED
-
Core Body Temperature Measurement During Hot and Cold Environmental Exposure
NCT01793337 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Non-invasive Temperature Measurement in Deep Hypothermia
NCT02009059 ·Status: UNKNOWN
-
Correlation Between Core Temperature and Skin Temperature in Pediatrics
NCT04057612 ·Status: COMPLETED
-
Correlation Between Core Temperature and Skin Temperature Measured by 3M SpotOn
NCT03745079 ·Status: UNKNOWN
-
Accuracy of Non-contact Thermometry
NCT03477357 ·Status: COMPLETED
-
Validation of the Measurement Accuracy of the Tcore Thermometer
NCT04489927 ·Status: TERMINATED
-
Continuous Temperature Measurement for Syndromic Surveillance
NCT03345277 ·Status: WITHDRAWN
-
Diagnostic Accuracy of Body Temperature Measurement in Geriatric Patients
NCT01639430 ·Status: COMPLETED
-
Comparison of the Performance of TMS-thermometer With Standard Esophageal or Urine Bladder Thermometer
NCT01196663 ·Status: UNKNOWN ·Phase: NA
-
The Clinical Performance Validation of Electronic Thermometer and Infrared Thermometers
NCT06353490 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Intraoperative Warming During Major Surgical Procedures Using the Esophageal Temperature Management System
NCT03790683 ·Status: TERMINATED ·Phase: NA
-
Comparison Between Non-invasive Heat-flux and Invasive Core Temperature Monitoring
NCT03368040 ·Status: COMPLETED
-
Accuracy of the Drager Dual-sensor Temperature Measurement System
NCT00980642 ·Status: COMPLETED ·Phase: NA
-
Investigation of the Accuracy of Temporal Artery Thermometers
NCT01817881 ·Status: COMPLETED
-
The Impact of Targeted Temperature Management Duration on Thrombin Function in Cardiac Arrest Patients
NCT06543849 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Evaluation of Infrared Cameras and Non-contact Infrared Thermometers for Measuring Body Temperatures
NCT04370743 ·Status: COMPLETED
-
Accuracy of Body Temperature Measurements Using the Esophageal Temperature Probe Inserted Through the Gastric Lumen of Supraglottic Airway Device
NCT04485923 ·Status: COMPLETED
-
Accuracy of Core Body Temperature Measurement Depending on Oesophageal Probe Tip Location
NCT06370676 ·Status: COMPLETED ·Phase: NA
-
Correlation Between Esophageal Temperature and Skin Temperature in Trauma Patients
NCT05770830 ·Status: COMPLETED
-
Temperature Measurement Using a Non Invasive Device
NCT01584401 ·Status: UNKNOWN
-
Correlation, Accuracy, Precision and Practicability of Zero Heat Flux Temperature Monitoring
NCT02031159 ·Status: COMPLETED
-
The Effects of Ambient Temperature and Forced-air Warming on Intraoperative Core Temperature
NCT02715076 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Zero Heat Flux Cutaneous Temperature in Intensive Care Adults
NCT02931227 ·Status: COMPLETED ·Phase: NA