Combination of InnoSEAL Plus TR Band Compared to TR Band Alone

NCT04380883 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 714

Last updated 2022-10-20

No results posted yet for this study

Summary

Angiography or angioplasty are commonly now done through inserting the device through radial artery in hand i.e. trans-radial procedures. It is reported that between 2-30% of these procedures get complicated by radial artery occlusion (RAO) which limit future use of this site for similar procedures if needed. It is important to control the arterial bleeding after the procedure completion while maintaining radial arterial flow appears to be an important factor in reducing RAO (patent hemostasis). Currently the most frequently employed method for hemostasis following trans-radial procedures is a compression device (RCD) such as TransRadial Bands (TRB). But TRB takes hours to achieve hemostasis and causes discomfort to the patients and longer time to discharge. Hemostatic pads offer an alternative to RCD where overall compression time is inherently low and patent hemostasis can possibly be achieved. The combined use of TR band with a hemostatic device may allow ease of use with reduced hemostasis time.

The trial aims to test the hypothesis that compared to TR band (TRB) alone, catecholamine chitosan-based pad (InnoSEAL hemostatic pad, InnoTherapy, Inc.) used in conjunction with TRB (InnoSEAL+TRB)is nearly as good as TRB alone in terms of the outcomes like RAO and hematoma.

Conditions

  • Radial Artery Occlusion
  • Hematoma

Interventions

DEVICE

InnoSEAL+TRB

InnoSEAL is a catecholamine chitosan-based pad (InnoSEAL hemostatic pad, InnoTherapy, Inc.). Chitosan-Catechol in InnoSEAL instantly forms an adhesive barrier upon blood contact. It is intended for use under the care of a healthcare professional. The dressing is indicated for the skin surface puncture sites for vascular procedures, percutaneous catheters/tubes. TRB is a pneumatic device which is applied routinely at the puncture site and inflated with air to stop bleeding from the access site. We will apply InnoSEAL and TRB together.

DEVICE

TRB alone

TRB is a pneumatic device which is applied routinely at the puncture site and inflated with air to stop bleeding from the access site. It will be the comparing arm.

Sponsors & Collaborators

  • Tabba Heart Institute

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2020-06-03
Primary Completion
2020-11-30
Completion
2020-11-30