Real-world Study on Fenestrated Stent for Thoracic Aortic Dissection
NCT07268755 · Status: ACTIVE_NOT_RECRUITING · Type: OBSERVATIONAL · Enrollment: 320
Last updated 2025-12-08
Summary
Study Title:
"Multi-center Real-world Study on Straight Tubular Thoracic Aortic Perforated Stent-Graft System for Treating Thoracic Aortic Dissection"
Purpose:
This study aims to evaluate the effectiveness of the Talos stent-graft system, a new device designed to treat aortic dissection (a life-threatening condition where the inner layer of the aorta tears). The stent has unique features like perforations and tapered design to reduce complications compared to traditional stents.
Key Features of the Talos Stent:
Longer length to cover more of the damaged aorta Perforated design at the distal end to improve blood flow Tapered shape to better match natural aortic anatomy Potentially reduces risks like new tears or spinal cord ischemia
Study Details:
Type: Real-world study (combining prospective and retrospective data) Duration: 3 years (2024-2027) Participants: 320 patients across 5 major hospitals in Shanghai Follow-up: Regular check-ups at 1, 3, 6, 12, and 24 months post-surgery Who Can Participate?
Patients may qualify if they:
Are ≥18 years old Have aortic dissection requiring treatment Have suitable blood vessels for stent placement Can commit to follow-up visits Who Cannot Participate?
Patients with:
Connective tissue disorders (e.g., Marfan syndrome) Active infections or cancer with limited life expectancy Severe allergies to stent materials/contrast dye Pregnancy or planning pregnancy What Does Participation Involve? Pre-Surgery: Physical exams, blood tests, CT scans Surgery: Minimally invasive stent placement via groin artery Post-Surgery: Blood pressure management, antiplatelet medication (e.g., aspirin) Follow-up: CT scans and quality-of-life questionnaires
Potential Benefits:
Improved aortic healing Reduced need for repeat surgeries Better quality of life (measured by VascuQoL questionnaire)
Possible Risks:
Standard stent risks (bleeding, infection, allergic reactions) Device-related complications (leaks, migration, new tears) Organ ischemia (reduced blood flow to kidneys/other organs)
Safety Monitoring:
Independent review of all CT scans 24/7 access to vascular specialists Immediate reporting of any complications
Ethical Protections:
Approved by ethics committees at all hospitals Voluntary participation with signed consent Right to withdraw anytime without affecting care
For Healthcare Providers:
This investigator-initiated study (IIS) is funded by Shanghai Science \& Technology Commission. It uses standardized protocols across centers with electronic data capture (EDC) for consistency. The primary endpoint is 12-month treatment success (defined as technical success + no reintervention). Secondary endpoints include aortic remodeling rates and complication profiles.
Contact Information:
Principal Investigator: Dr. Meng Qingyou Institution: Shanghai General Hospital Phone: +86-133-0621-1019
Conditions
- Thoracic Aortic Dissection
- Thoracic Aortic Disease
Interventions
- DEVICE
-
TALOS
A Real-World Study on the Effectiveness of the Talos Thoracic Stent Graft System in Thoracic Endovascular Aortic Repair for Aortic Dissection.
Sponsors & Collaborators
-
Qingyou Meng
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-12-01
- Primary Completion
- 2027-11-30
- Completion
- 2027-11-30
- FDA Device
- Yes
Countries
- China
Study Locations
More Related Trials
-
To Evaluate the Safety and Efficacy for GORE TAG Thoracic Endoprosthesis in the Treatment of Thoracic Aortic Disease
NCT00757003 ·Status: COMPLETED ·Phase: PHASE3
-
The Branch-based Intraoperative Stent System in the Treatment of Stanford A Aortic Dissection(BROAD)
NCT05659641 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
the Aorta Arch Stent Graft System Combined With the Endovascular Needle System in Situ Fenestration
NCT05126446 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
VALOR: The Talent Thoracic Stent Graft System Clinical Study
NCT00604799 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Evaluation of the Valiant Mona LSA Thoracic Stent Graft System in Descending TAA and Chronic Dissections
NCT02365467 ·Status: COMPLETED
-
Evaluating the Feasibility of Bioresorbable Iron-Based Covered Stent: A Clinical Trial
NCT07316855 ·Status: RECRUITING ·Phase: NA
-
Triple-branch Stent Graft Placement for the Treatment of Acute DeBakey I Aortic Dissection
NCT02732340 ·Status: COMPLETED ·Phase: NA
-
Prospective, Multicenter, Single-Arm Study of Aortic Arch Pathology Reconstruction
NCT07139912 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Post-Approval Clinical Study of the Talent Thoracic Stent Graft to Treat Thoracic Aortic Aneurysms (THRIVE)
NCT00805948 ·Status: TERMINATED ·Phase: NA
-
Phase II Clinical Study of the Safety and Efficacy of the Relay Thoracic Stent-Graft
NCT01327742 ·Status: APPROVED_FOR_MARKETING
-
Study to Evaluate the Clinical Performance of the Valiant Thoracic Stent Graft With the Captivia Delivery System (Valiant Captivia) for the Treatment of Acute, Complicated Type B Aortic Dissections
NCT01114724 ·Status: COMPLETED ·Phase: NA
-
Guo's Endovascular Aortic Arch Replacement of Aortic Dissection by WeFlow-Tribranch Endoprothesis: a Multicenter Pilot Study(GRAFT Study)
NCT05754541 ·Status: RECRUITING ·Phase: NA
-
Thoracoabdominal Artery Stent Graft System Exploratory Study
NCT06710938 ·Status: RECRUITING ·Phase: NA
-
RelayPro Thoracic Stent-Graft in Subjects With Thoracic Aortic Aneurysms and Penetrating Atherosclerotic Ulcers
NCT02818972 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Study on the Aortic Arch Single Branch Stent Graft System
NCT06915545 ·Status: RECRUITING ·Phase: NA
-
Safety and Efficacy Study of Fabulous Stent Graft System for Stanford B Aortic Dissection
NCT04918212 ·Status: COMPLETED ·Phase: NA
-
Triple Branched Stent Graft System for Aortic Arch Lesions
NCT07067840 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A European Study on Medical Management Versus TAG Device + Medical Management for Acute Uncomplicated Type B Dissection
NCT00742274 ·Status: COMPLETED ·Phase: NA
-
Clinical Study of Thoracic Aortic Aneurysm Exclusion
NCT00549315 ·Status: UNKNOWN ·Phase: NA
-
Study of the RelayPro Thoracic Stent-Graft in Subjects With an Acute, Complicated Type B Aortic Dissection
NCT03033043 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Post-Approval Trial of the Talent™ Abdominal Stent Graft to Treat Aortic Aneurysms
NCT00816062 ·Status: COMPLETED ·Phase: NA
-
Study on Multibranched Stent Graft System in the Treatment of Thoracoabdominal Aortic Aneurysm
NCT06478576 ·Status: RECRUITING ·Phase: NA
-
Clinical Study of Abdominal Aortic Aneurysm Exclusion (TALENT Abdominal)
NCT00549432 ·Status: UNKNOWN ·Phase: NA
-
Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis
NCT04815785 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
CRATOS - Evaluation of Cratos™ Branch Stent Graft System in Treatment of Descending Aorta Lesions
NCT05874206 ·Status: RECRUITING ·Phase: NA