Healthy Volunteer Study to Evaluate the Impact of Various Common Interventions on Venous Pressure Signal Captured by PIVA
NCT04324593 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 26
Last updated 2021-04-01
Summary
Non-invasive sensors have been used in research in the United States (US) to aid in the assessment of a subject's heart rate (HR), respiratory rate (RR) and fluid volume status. This estimate and its trended value over time, when used along with clinical signs and symptoms and other subject test results, can aid in the process of reaching a diagnosis and formulating a therapeutic plan when abnormalities of volume status, or RR are suspected.
Non-invasive sensors like the Peripheral IntraVenous Analysis (PIVA) sensor under development by Baxter and the Deltran blood pressure (BP) transducer, capture waveforms created by physiological mechanisms such as blood flow and breathing. An algorithm is then applied to the captured waveform to give clinicians an idea of hemodynamic (volume) status, and RR.
In this study, the functional robustness (e.g., subjects sitting, elevated leg positions, etc.) of the PIVA algorithm/technology will be demonstrated by evaluating the impact of various common interventions on the venous pressure signal. All subjects will undergo 33 interventions expected to take approximately 4 - 6 hours.
Conditions
- Healthy Volunteers
Interventions
- DEVICE
-
Peripheral intravenous analysis (PIVA) algorithm
An IV line with an attached Deltran BP transducer will be used together with LabChart software to record venous waveforms during various interventions. These waveforms will be processed using the PIVA algorithm and the calculated values will be compared to those from Nellcor respiratory monitor, Capnograph and cardiac telemetry monitoring.
Sponsors & Collaborators
-
Baxter Healthcare Corporation
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- DEVICE_FEASIBILITY
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 55 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2020-02-26
- Primary Completion
- 2020-03-21
- Completion
- 2020-03-21
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Positive Airway Pressure Therapy Study in Sleep Apnea and Diastolic Heart Failure
NCT02254382 ·Status: TERMINATED ·Phase: NA
-
The HeartWare™ Ventricular Assist System as Destination Therapy of Advanced Heart Failure: the ENDURANCE Trial
NCT01166347 ·Status: COMPLETED ·Phase: NA
-
Monitoring Outpatient Blood VolumE in Heart Failure
NCT04660396 ·Status: COMPLETED
-
Evaluation of the HeartWare Left Ventricular Assist Device for the Treatment of Advanced Heart Failure
NCT00751972 ·Status: COMPLETED ·Phase: NA
-
Pleth Variability Index (PVI) as a Measure of Volume Status During Transcatheter Mitral Valve Repair
NCT03993938 ·Status: COMPLETED ·Phase: NA
-
A Clinical Trial to Evaluate the HeartWare™ Ventricular Assist System (ENDURANCE SUPPLEMENTAL TRIAL)
NCT01966458 ·Status: COMPLETED ·Phase: NA
-
CorWave LVAS FIH Study
NCT06907017 ·Status: RECRUITING ·Phase: NA
-
The Effects of Nitric Oxide for Inhalation During Left Ventricular Assists Device (LVAD) Implantation
NCT00060840 ·Status: COMPLETED ·Phase: PHASE2
-
Influence of Right Ventricular Function on Changes in Exercise Capacity After LVAD
NCT05916612 ·Status: WITHDRAWN
-
Clinical Trial of Ventiflow LP Supporting High-risk Percutaneous Coronary Intervention(PCI)
NCT06754839 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Physiological Control for Mechanical Circulatory Devices
NCT04786236 ·Status: TERMINATED ·Phase: NA
-
VERITAS: An Evaluation of the Veniti Vidi Retrievable Inferior Vena Cava Filter System in Patients at Risk for Pulmonary Embolism
NCT01787773 ·Status: WITHDRAWN ·Phase: NA
-
Endothelial Function and Circulating Microparticle in Patients Under LVAD Support
NCT03923413 ·Status: COMPLETED
-
Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device (LVAD) and Medical Management
NCT01452802 ·Status: COMPLETED
-
Ventricular Assist Device (VAD) Research Registry and Blood Sub-Study
NCT05637242 ·Status: TERMINATED
-
Adaptive Servo-Ventilation In Acute Heart Failure Patients Protecting the Heart and Kidneys
NCT02796638 ·Status: UNKNOWN ·Phase: NA
-
PV Loop & Coarctation Study
NCT05362721 ·Status: ACTIVE_NOT_RECRUITING
-
Magenta Elevate™ Clinical Feasibility Study in Cardiogenic Shock
NCT07293923 ·Status: RECRUITING ·Phase: NA
-
SyncAV Post-Market Trial
NCT04100148 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Thoratec HeartMate II Left Ventricular Assist System (LVAS) for Destination Therapy
NCT00121485 ·Status: COMPLETED ·Phase: NA
-
Assessment of Safety and Accuracy of the Microtech System in Patients Undergoing Left Ventricular Assist Device Implantation
NCT06682910 ·Status: RECRUITING ·Phase: NA
-
Study of Safety and Efficacy of the Percutaneous Reduction of Mitral Valve Regurgitation in Heart Failure Patients
NCT00787293 ·Status: SUSPENDED ·Phase: PHASE2
-
Caisson Transcatheter Mitral Valve Replacement (TMVR) System Early Feasibility Study
NCT02768402 ·Status: UNKNOWN ·Phase: NA
-
Cardiovascular Improvements With MV ASV Therapy in Heart Failure
NCT01953874 ·Status: TERMINATED ·Phase: NA
-
Testing of a Valsalva Assist Device (VAD) in Healthy Volunteers Performing a Valsalva Manoeuvre
NCT03298880 ·Status: COMPLETED ·Phase: NA