Pleth Variability Index (PVI) as a Measure of Volume Status During Transcatheter Mitral Valve Repair
NCT03993938 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2022-06-24
Summary
Transcatheter mitral valve repair in the form of MitraClip® is a safe and effective alternative to surgical mitral valve repair/replacement in patients with high operative morbidity and mortality risk. Successful MitraClip application depends on intraprocedural quantification of mitral regurgitation and left atrial pressure (LAP) monitoring. The pleth variability index (PVI) is a noninvasive, dynamic index based on analysis of the respiratory variations in the plethysmographic waveform recorded transcutaneously by the pulse oximeter. Studies demonstrate that PVI is accurate in predicting fluid responsiveness in mechanically ventilated adult patients. In this study, we wish to measure PVI during TMVR and correlate with invasive indices such as left atrial pressure (LAP) and stroke volume variation. Our study hopes to provide a real-time non-invasive alternative to invasive indices to better guide fluid management and improve hemodynamics.
Conditions
- Mitral Regurgitation
Interventions
- DEVICE
-
PVI measurement
Masimo Radical-7® probe to be attached to patient's finger along with standard ASA monitors at the start of procedure. After placement of arterial line, stroke volume variation (SVV) and pulse pressure variation (PPV) to be recorded along with pleth variability index (PVI) every 5 minutes. Intraprocedure left atrial pressure (LAP) (v-wave and mean) to be recorded prior to and after MitraClip deployment. Data to be analyzed - age, sex, BMI; Preprocedure ejection fraction (EF), pulmonary artery pressure (PAP), rhythm, mitral regurgitation severity; heart rate, systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial pressure (MAP) every 5 minutes; SVV, PPV, PVI every 5 minutes; LAP prior to mitraclip deployment; LAP after mitraclip deployment
Sponsors & Collaborators
-
Henry Ford Health System
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- SUPPORTIVE_CARE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-10-01
- Primary Completion
- 2021-06-01
- Completion
- 2021-06-01
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
MitraClip® Registry
NCT02033811 ·Status: RECRUITING
-
Caisson Transcatheter Mitral Valve Replacement (TMVR)
NCT03661398 ·Status: UNKNOWN ·Phase: NA
-
Transcatheter Mitral Valve Repair for the Treatment of Mitral Valve Regurgitation In Heart Failure (The EVOLVE-MR Trial)
NCT03891823 ·Status: TERMINATED ·Phase: NA
-
Safety and Efficacy of the Percutaneous Transvenous Mitral Annuloplasty Device to Reduce Mitral Regurgitation
NCT00568230 ·Status: COMPLETED ·Phase: PHASE1
-
Implantation of a Permanent Interatrial Shunt to Reduce Left Atrial Filling Pressures Following MitraClip
NCT04729933 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Munich Transcatheter Mitral Valve Safety and Effectiveness
NCT05871983 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Transcatheter Mitral Valve Replacement System (TMVR) Pilot Study and The Early Feasibility Study of the TMVR Transseptal System
NCT02322840 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Half Moon Transcatheter Mitral Valve Repair (TMVr) Pilot Study
NCT04343313 ·Status: RECRUITING ·Phase: NA
-
To Evaluate the Efficacy and Safety of the Transfemoral Mitral Valve Repair System in the Treatment of Patients With Moderately Severe and Severe Functional Mitral Regurgitation(FMR) Who Remained Clinically Symptomatic After Guideline-directed Medical Treatment
NCT05508438 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Mi-STITCH™ and Mi-KNOT™ Device Technologies - Improvement of Mitral Valve Repair
NCT05034471 ·Status: UNKNOWN ·Phase: NA
-
Pivotal Study of a Percutaneous Mitral Valve Repair System
NCT00209274 ·Status: COMPLETED ·Phase: NA
-
Endothelial Function in Mechanical Circulatory Support
NCT04539093 ·Status: COMPLETED
-
MitraClip® and Hemodynamic Effects of Relevant Iatrogenic Atrial Septum Defect Closure
NCT03024268 ·Status: UNKNOWN ·Phase: NA
-
Early Feasibility of the Mitralign Percutaneous Tricuspid Valve Annuloplasty System (PTVAS) Also Known as TriAlign™.
NCT02574650 ·Status: UNKNOWN ·Phase: NA
-
Study of Safety and Efficacy of the Percutaneous Reduction of Mitral Valve Regurgitation in Heart Failure Patients
NCT00787293 ·Status: SUSPENDED ·Phase: PHASE2
-
Clinical Trial of Ventiflow LP Supporting High-risk Percutaneous Coronary Intervention(PCI)
NCT06754839 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Sutra Hemi-valve First-in-Human Study
NCT06552689 ·Status: RECRUITING ·Phase: NA
-
Mitral Valve Regurgitation Quantification From 3D Color Doppler Ultrasound - Standard of Care Data Collection
NCT03286088 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Minimally Invasive VenTouch™ System in the Treatment of Functional Mitral Valve Regurgitation (FMR)
NCT02671799 ·Status: UNKNOWN ·Phase: NA
-
Efficacy of MitraCLip Vs. PASCAL for the TrEAtment of MitraL REgurgiTation in an All-comer Population
NCT06634121 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Outcomes of CRT and MitraClip for Treatment of Low Ejection Fraction and Functional Mitral Regurgitation in HF
NCT02985268 ·Status: WITHDRAWN ·Phase: NA
-
Safety and Efficacy Study of the PTMA Device to Reduce Mitral Valve Regurgitation in Patients With Heart Failure
NCT00815386 ·Status: SUSPENDED ·Phase: PHASE2/PHASE3
-
MitraClip® After Surgical Mitral Valve Repair
NCT02853955 ·Status: UNKNOWN
-
Belgian Mitraclip Registry
NCT02506387 ·Status: COMPLETED
-
VIVID - Valvular and Ventricular Improvement Via iCoapsys Delivery - Feasibility Study
NCT00512005 ·Status: UNKNOWN ·Phase: PHASE1