Proximal Versus Distal Segments of No-Touch Saphenous Vein Grafts
NCT04284956 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 100
Last updated 2020-03-17
Summary
The optimum segment of No-Touch veins for bypassing is still undefined. The purpose of this study is to assess the incidence of leg wound complication after No-Touch harvesting of proximal segment of saphenous veins compared to distal segment of veins in the leg. Graft occlusion rates between the two segments of veins for bypassing will also be compared during follow-up.
Conditions
- Leg Wound Complication After No-Touch Harvestingof Veins
Interventions
- PROCEDURE
-
Proximal and distal segment of saphenous vein harvested by No-Touch technique
two longitudinal incisions are made on the thigh and shank from unilateral lower limb (for harvesting of proximal segment of saphenous vein, incision is started from about 3 or 4cms inferolateral to the pubic tubercle and then extended downward). As previous reported. the adventitia and perivascular tissue are carefully kept intact to avoid damage. Then a margin of about 5 mm from both sides of the vein is created to include the fat pedicle using electrocautery, and all visible side branches are ligated with 4-0 silk or by metal clipping (branches are divided at the pedicle margin rather than the vein trunk). The saphenous vein is then separated from its bed using scissors and electrocautery, together with surrounding tissue.
Sponsors & Collaborators
-
China National Center for Cardiovascular Diseases
lead OTHER_GOV
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-03-01
- Primary Completion
- 2020-06-30
- Completion
- 2021-06-30
Countries
- China
Study Locations
More Related Trials
-
A Clinical Trial on No-touch Vein Graft (NT-graft) in Coronary Surgery
NCT03501303 ·Status: COMPLETED ·Phase: NA
-
Radial Artery Versus No-touch Saphenous Vein
NCT06014047 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Clinical Impact of Surgical Wound Morbidity According to the Type of Saphenous Vein Harvesting Technique (Endoscopic vs. Open) in Patients Undergoing Myocardial Revascularization Surgery
NCT07002658 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of Saphenous Vein Graft Harvested From Upper Versus Lower Leg in Coronary Artery Bypass Grafting
NCT01974492 ·Status: COMPLETED ·Phase: NA
-
Assessing Vein Graft Properties Between Conventional & No-Touch Harvesting Technique - (PATENT SVG)
NCT01488084 ·Status: COMPLETED ·Phase: PHASE1
-
Shockwave Intervention for Enhanced Wound Healing in No-touch Pedicle Saphenous Vein Graft Harvesting for Coronary Artery Bypass Grafting
NCT07068776 ·Status: RECRUITING ·Phase: NA
-
Compare Endoscopic and Open Methods of Vein Harvesting for Coronary Artery Bypass Grafting
NCT02446522 ·Status: COMPLETED ·Phase: PHASE4
-
Total Arterial vs. Mixed Grafting in Left Coronary CABG
NCT07057713 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Saphenous Vein as Y-composite Versus Aortocoronary Conduit for CABG
NCT05704296 ·Status: RECRUITING ·Phase: NA
-
Five-year Patency of No-touch Saphenous Vein Grafts in On-pump Versus Clamp-less Off-pump Coronary Artery Bypass Surgery
NCT03447197 ·Status: COMPLETED ·Phase: NA
-
Endoscopic Vessel Harvesting During Coronary Bypass Surgery
NCT00235846 ·Status: COMPLETED ·Phase: NA
-
Endoscopic Saphenous Vein Harvest for Coronary Artery Bypass Grafting
NCT00712192 ·Status: COMPLETED ·Phase: NA
-
One-year Patency Comparison Between Radial Artery and No-touch Saphenous Vein Grafts in Women Undergoing Isolated CABG
NCT06179329 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Graft Material in Coronary Artery Bypass Grafting (CABG)
NCT01310725 ·Status: COMPLETED ·Phase: NA
-
Study to Improve Long Term Vein Graft Patency After Coronary Bypass Surgery by Using a Novel Endoscopic Harvesting Technique
NCT01540422 ·Status: COMPLETED
-
A Prospective Randomized Study for Comparison of Y-Composite Grafts
NCT01051986 ·Status: COMPLETED ·Phase: NA
-
Long-term Results Following Endoscopic Vein Harvesting in Coronary Artery Bypass Surgery
NCT01480726 ·Status: COMPLETED
-
Radial Artery Versus Saphenous Vein Patency (RSVP) Study
NCT00139399 ·Status: COMPLETED ·Phase: PHASE3
-
Improving the Results of Heart Bypass Surgery Using New Approaches to Surgery and Medication
NCT01047449 ·Status: COMPLETED ·Phase: NA
-
IVUS Study for SV Graft: Y-composite vs Aortocoronary Conduit
NCT04782492 ·Status: COMPLETED ·Phase: NA
-
Multicentre Radial Artery Patency Study: Results of Patency Beyond 5 Years After Coronary Artery Bypass Surgery
NCT00187356 ·Status: COMPLETED ·Phase: PHASE3
-
Coronary Artery Bypass Grafting: Factors Related to Late Events and Saphenous Graft Patency
NCT00755248 ·Status: UNKNOWN
-
Ultrasound to Prevent Leg Wound Complications in Heart Bypass.
NCT02307084 ·Status: TERMINATED ·Phase: NA
-
Neurological Complications Comparing Endoscopically vs. Open Harvest of the Radial Artery
NCT01848886 ·Status: COMPLETED ·Phase: NA
-
The Long-term Results of the No-touch Vein Graft to the Left Anterior Descending Artery.
NCT02339857 ·Status: COMPLETED