A Comparison of CPR Outcomes Between Traditional and Endomorphic Manikins With and Without Equipment
NCT04283214 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2020-05-22
Summary
The study's research design is a randomized experiment. 50 emergency responders (emergency medical responders, emergency medical technicians, advanced emergency medical technicians, and paramedics) will be recruited for this research. All data collection will take place in Lab 14 of the Benson Bunker Fieldhouse or a professional, confidential location of the participant's choosing.
Prior to CPR performance, participants will be given an informed consent form to sign. The form will be explained in detail by the researcher collecting data. After obtaining informed consent, participants will be asked to fill out a demographic questionnaire to collect information such as age, gender, years of emergency responder experience/employment, and years of CPR certification. Demographic information provided by participants will be utilized in data analysis. The demographics form should take approximately five minutes to complete. Participants will be randomly assigned to the four trials they will partake in and instructed via oral script (one for over and one for under football shoulder pads) to perform four-trials total of three-minute single-rescuer CPR on both a traditional CPR manikin and "Fat Old Fred" (bariatric) CPR manikin. CPR must be performed in accordance with the American Heart Association's 2015 CPR Guidelines and participants will use a CPRmeter 2 device to collect data to determine the quality of CPR components (chest compression depth/recoil, compression rate, CPR compression duration, mean depth, mean rate, and total number of compressions). The entire study session should take 25 to 30 minutes to complete.
Conditions
- Cardiac Arrest
Interventions
- OTHER
-
Cardiopulmonary Resuscitation
Cardiopulmonary Resuscitation based on 2015 American Heart Association guidelines with and without protective equipment on traditional and endomorphic manikins
Sponsors & Collaborators
-
North Dakota State University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- FACTORIAL
Eligibility
- Min Age
- 18 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2020-02-01
- Primary Completion
- 2020-03-16
- Completion
- 2020-03-16
Countries
- United States
Study Locations
More Related Trials
-
Evaluation of Efficacy of Online Real-time Home CPR Training Program
NCT05023616 ·Status: COMPLETED ·Phase: NA
-
Monitoring of Intubation and Ventilation During Resuscitation
NCT00204217 ·Status: COMPLETED ·Phase: PHASE2
-
The Holistic Health Care of Post-Cardiac Arrest Survivors: From Patient's Health to Family Resilience
NCT04859270 ·Status: RECRUITING
-
Optimal Training Frequency for Attainment and Maintenance of High-quality CPR on a High-fidelity Manikin
NCT02998307 ·Status: COMPLETED ·Phase: NA
-
Registry Study of Extracorporeal Cardiopulmonary Resuscitation (eCPR) in China
NCT04956497 ·Status: UNKNOWN
-
Apneic Oxygenation Via Nasal Cannulae Prevents Arterial Hypoxemia
NCT00782977 ·Status: COMPLETED ·Phase: NA
-
Outcomes and Risk Factors of CPR in PICU
NCT06300710 ·Status: NOT_YET_RECRUITING
-
Continuous Chest Compressions vs AHA Standard CPR of 30:2
NCT01372748 ·Status: COMPLETED ·Phase: PHASE4
-
Cerebral Oximetry and NIRS in Cardiac Arrest Patients
NCT03769740 ·Status: UNKNOWN
-
The Evaluation of Optimal Observation Period for Neurological Recovery in Post-arrest Survivors
NCT04967261 ·Status: COMPLETED
-
International Device Assisted Controlled Sequential Elevation CPR Registry
NCT05588024 ·Status: RECRUITING
-
Hemodynamic Effects of Standard Cardiopulmonary Resuscitation (CPR), Active Compression Decompression CPR With an Inspiratory Impedance Device, and Standard CPR With an Intrathoracic Pressure Regulator During Out-of-hospital Cardiac Arrest
NCT01325870 ·Status: COMPLETED ·Phase: NA
-
Automated Chest Compression in Cardiac Arrest
NCT00641069 ·Status: COMPLETED
-
Comparison of the Quality of CPR by Lay Rescuers With and Without Feedback Devices
NCT02000505 ·Status: UNKNOWN ·Phase: NA
-
Comparison of the Efficiency of Mouth-to-nose Breathing With Mouth-to-mouth Breathing
NCT00785447 ·Status: COMPLETED ·Phase: NA
-
Automated Chest Physiotherapy to Improve Outcomes in Neuro
NCT00571623 ·Status: COMPLETED
-
Effect of Capnography Feedback During Cardiopulmonary Resuscitation (CPR ) on Patient's Outcome
NCT02045498 ·Status: COMPLETED ·Phase: NA
-
Assessment of Preoxygenation Strategies in the Prehospital Environment
NCT02694705 ·Status: COMPLETED ·Phase: NA
-
Three Different Cardiopulmonary Resuscitation (CPR) Training Methods
NCT01361919 ·Status: COMPLETED ·Phase: NA
-
Application of Mechanical Cardiopulmonary Resuscitation Devices and Their Value in Out-of-hospital Cardiac Arrest: A Retrospective Analysis of the German Resuscitation Registry
NCT02932124 ·Status: COMPLETED
-
MIHS Emergency Department CPR Quality Improvement Project
NCT01245699 ·Status: COMPLETED ·Phase: NA
-
Improved Patient Recovery After Anesthesia With Hypercapnia Hyperpnoea
NCT00708526 ·Status: COMPLETED ·Phase: NA
-
Dispatcher-Assisted CPR: Low-Dose, High-Frequency Simulation-Based Training
NCT04085692 ·Status: COMPLETED ·Phase: NA
-
Comparison of Manual Cardiopulmonary Resuscitation (CPR) Versus Automatic CPR Machine During Ambulance Transport.
NCT00308815 ·Status: UNKNOWN ·Phase: NA
-
Predictors for Survival and Good Neurological Outcome in E-CPR and Non CPR Treated Patients
NCT04198792 ·Status: RECRUITING