Summary
More than 300,000 Americans experience out-of-hospital cardiac arrest annually, with overall survival rates averaging less than 5%. Low survival rates persist, in part, because manual chest compressions and ventilation, termed standard cardiopulmonary resuscitation (S-CPR), is an inherently inefficient process, providing less than 25% of normal blood flow to the heart and the brain. Hemodynamics are often compromised further by poor S-CPR techniques, especially inadequate chest compression and incomplete chest recoil. Active Compression Decompression CPR (ACD-CPR) is performed with a hand-held device that is attached to the patient's chest, and also includes a handle containing a metronome and force gauge to guide proper compression rate, depth and complete chest wall recoil. The impedance threshold device (ITD) is designed for rapid connection to an airway adjunct (e.g. facemask or endotracheal tube) and allows for positive pressure ventilation, while also impeding passive inspiratory gas exchange during chest wall decompression. Prior studies have shown that the combination of ACD-CPR + ITD enhances refilling of the heart after each compression by augmenting negative intrathoracic pressure during the decompression phase of CPR, resulting in improved cardiac and cerebral perfusion. The intrathoracic pressure regulator (ITPR) is a next generation inspiratory impedance therapy. The ITPR uses a regulated external vacuum source to lower the negative intrathoracic pressure and is therefore less dependent on the quality of CPR (e.g., completeness of chest wall recoil). The ITPR generates a pre-set continuous and controlled expiratory phase negative intrathoracic pressure that is interrupted only when positive pressure ventilation is needed to maintain oxygenation and provide gas exchange.
The purpose of the study is to compare the early safety and hemodynamic effects of S-CPR, ACD- CPR + ITD, and S-CPR + ITPR in patients with out-of-hospital cardiac arrest.
Conditions
- Cardiac Arrest
- Sudden Cardiac Death
Interventions
- DEVICE
-
ACD-CPR
- DEVICE
-
ITPR
standard CPR with use of the CirQlator intrathoracic pressure regulator (ITPR)
- PROCEDURE
-
S-CPR
standard manual CPR
- DEVICE
-
Impedance Threshold Device (ITD)
Sponsors & Collaborators
-
National Heart, Lung, and Blood Institute (NHLBI)
collaborator NIH -
Advanced Circulatory Systems
lead INDUSTRY
Principal Investigators
-
Keith Lurie, MD · Advanced Circulatory Systems
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-03-31
- Primary Completion
- 2012-12-31
- Completion
- 2012-12-31
Countries
- United States
Study Locations
More Related Trials
-
Effects of Blood Flow of Venoarterial Extracorporeal Membrane Oxygenation Life Support on Microcirculation
NCT03210818 ·Status: COMPLETED
-
Continuous Chest Compressions vs AHA Standard CPR of 30:2
NCT01372748 ·Status: COMPLETED ·Phase: PHASE4
-
Head-up Position and High Quality Cardiopulmonary Resuscitation in OHCA
NCT03996616 ·Status: COMPLETED ·Phase: NA
-
Compression Only CPR Versus Standard CPR in Out-Of-Hospital Cardiac Arrest - A Randomized Survival Study
NCT03981107 ·Status: RECRUITING ·Phase: NA
-
Automated Chest Compression in Cardiac Arrest
NCT00641069 ·Status: COMPLETED
-
Optimizing Integration of CPR Feedback Technology With CPR Coaching for Cardiac Arrest
NCT03204162 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of SC-V Versus Conventional CPR
NCT00000502 ·Status: COMPLETED ·Phase: PHASE3
-
Synergy of Elevation of the Head and Thorax and REBOA During Out-of-Hospital Cardiac Arrest
NCT06537492 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Standard CPR Versus Chest Compressions Only
NCT04569812 ·Status: COMPLETED ·Phase: NA
-
Compression Only-CPR Versus Standard-CPR
NCT02401633 ·Status: COMPLETED ·Phase: NA
-
ON-SCENE Initiation of Extracorporeal CardioPulmonary Resuscitation During Refractory Out-of-Hospital Cardiac Arrest
NCT04620070 ·Status: COMPLETED ·Phase: NA
-
Predictors for Survival and Good Neurological Outcome in E-CPR and Non CPR Treated Patients
NCT04198792 ·Status: RECRUITING
-
Pediatric Resuscitation With Feedback CPR Devices
NCT02281903 ·Status: COMPLETED ·Phase: NA
-
Three Different Cardiopulmonary Resuscitation (CPR) Training Methods
NCT01361919 ·Status: COMPLETED ·Phase: NA
-
Definition of Hemodynamic Thresholds in Out-of-Hospital Cardiac Arrest
NCT03172468 ·Status: WITHDRAWN
-
Does Increasing the Compression Pause From 3 to 5 Seconds in Mechanical Compression Devices Increase Ventilation Success Rate and Return of Spontaneous Circulation?
NCT06824961 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Predicting Blood Pressure in Patients Following Defibrillation
NCT02686307 ·Status: COMPLETED
-
Circulation Improving Resuscitation Care (CIRC)
NCT00597207 ·Status: COMPLETED ·Phase: NA
-
The Haemodynamic Effects of Mechanical Standard and Active Chest Compression-decompression During Out-of-hospital CPR
NCT02479152 ·Status: COMPLETED ·Phase: NA
-
The Impact of Aortic Valve Compression During Cardio-pulmonary Resuscitation on Patients With Out-of-hospital Cardiac Arrest
NCT05932784 ·Status: COMPLETED
-
Non Invasive Neuromonitoring After Cardiac Arrest
NCT02575196 ·Status: COMPLETED
-
Tourniquets Increase Proximal Pressure
NCT05324306 ·Status: COMPLETED ·Phase: NA
-
Flowchart-Assisted Resuscitation. Standard CPR vs. Chest Compressions Only: What Happened to the Quality?
NCT02438527 ·Status: COMPLETED ·Phase: NA
-
Implementation of Gold Standard EMS CPR Programs for 2% Improvement in Survival Rates of Out-of-Hospital Cardiac Arrest in a Metropolitan City
NCT02540629 ·Status: TERMINATED ·Phase: NA
-
Application of Mechanical Cardiopulmonary Resuscitation Devices and Their Value in Out-of-hospital Cardiac Arrest: A Retrospective Analysis of the German Resuscitation Registry
NCT02932124 ·Status: COMPLETED