Contrast Media Temperature and Patient Comfort in CT of the Abdomen
NCT04249479 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 218
Last updated 2021-04-02
Summary
Abdominal computed tomographic (CT) is an important prognostic tool with regard to the detection of oncological, infectious and other abdominal disorders.
The total iodine load (TIL) is regarded as a decisive factor in the opacification of parenchymal structures. The EICAR trial demonstrated that injection with high flow rates of prewarmed contrast media (CM) was safe and patients did not experience any pain, stress of discomfort during injection. Flow rates as high as 8.8 ml/s were injected without any discomfort. All concentrations used (e.g. 240, 300 and 370 mg I/ml) in this study were prewarmed. According to the recent recommendations (ESUR guidelines 10.0) it should be considered to warm iodine-based CM before administration. The hypothesis is that although using CM at room temperature (\~23°C \[\~73°F\]) might result in lower attenuation of the liver parenchyma than would be achieved using CM pre-warmed to body temperature, diagnostic image quality, patient safety and comfort will not be compromised by not pre-warming CM in this setting. According to the guidelines, it is regarded as best clinical practice to pre-warm CM. Surprisingly, these recommendations are merely based on a hypothetical assumption. In the literature, there are no studies evaluating this topic and it has never been clearly shown to result in a better patient comfort. For this reason, many clinics do not pre-warm their CM in daily clinical routine. Only one study evaluated subjective comfort in hysterosalpingography (HSG), in which CM is injected in to the cavity of the uterus. This study found that prewarmed CM alleviates the pain and decreased the incidence of vasovagal episodes during HSG. To the best of our knowledge, no study showed that prewarmed CM in CT resulted in higher patient comfort, in comparison to CM at room temperature (20° C).
Up till now, all CM in the department is prewarmed. In case this study does not show a difference in patient comfort, prewarming the CM can be stopped, resulting in a considerable simplified workflow.
The hypothesis is that usage of CM at room temperature (20° C) might result in a decreased level of patient comfort in abdominal CT, in comparison to pre-heated (37° C) CM, with no significant difference in diagnostic attenuation of the liver parenchyma between groups.
Conditions
- Contrast Media
- Comfort
- Temperature
- Abdomen
Interventions
- OTHER
-
CM Temperature (20° C)
CM will be administered at 20° C (room temperature).
- OTHER
-
CM Temperature (37° C)
CM will be administered at 37° C (pre-heated).
- OTHER
-
Weight
The patients' weight is measured prior to scanning by a technician on a weighing scale available in the scanner room.
Sponsors & Collaborators
-
Maastricht University Medical Center
lead OTHER
Principal Investigators
-
Joachim E Wildberger, Professor · Maastricht University Medical Center
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-02-03
- Primary Completion
- 2020-08-24
- Completion
- 2020-08-24
Countries
- Netherlands
Study Locations
More Related Trials
-
Dosing Iodinated Contrast Media According to Lean vs. Total Body Weight
NCT03415997 ·Status: COMPLETED ·Phase: PHASE4
-
Optimization of Contrast Agent Dose in CT With Lean Body Weight
NCT03384979 ·Status: COMPLETED ·Phase: PHASE4
-
Fully Automated Scan Technique Optimisation of Scan Timing in Chest CT
NCT03658200 ·Status: TERMINATED ·Phase: NA
-
Imaging Techniques in CT: Technical Development
NCT02242448 ·Status: TERMINATED
-
Thoracoabdominal Arortic CTA Study
NCT02291718 ·Status: COMPLETED ·Phase: PHASE4
-
Influence of Patient Position on Attenuation Artifacts Observed in D-SPECT Camera Myocardial Tomoscintigraphy
NCT02872545 ·Status: UNKNOWN ·Phase: NA
-
Limited Abdominal CT in ED Patients With Abdominal Pain
NCT02146521 ·Status: WITHDRAWN
-
Comparison of Contrast Agent Administration Protocols
NCT04300972 ·Status: COMPLETED ·Phase: NA
-
Effect of Snapshot Freeze on Cardiac CT Image Quality
NCT02618473 ·Status: COMPLETED ·Phase: NA
-
Individualized Volume of Oral Contrast Agent in CT Enterography
NCT03808649 ·Status: UNKNOWN ·Phase: NA
-
Improved Chest CT Diagnostic and Contrast Medium Administration
NCT05645796 ·Status: COMPLETED ·Phase: NA
-
Plain Magnetic Resonance (MR) in the Assessment of Patients With Acute Abdomen
NCT01044173 ·Status: WITHDRAWN ·Phase: NA
-
The Feasibility of a Radiological Score Based on CT Signs for Recognizing Salvageable Bowel in Acute Mesenteric Ischemia
NCT06445660 ·Status: RECRUITING
-
Abdominal Computed Tomography and the Blood Reactive Oxygen Species Level
NCT00745641 ·Status: WITHDRAWN
-
A Non-interventional Study to Observe the Computed Tomographic Angiography Image Quality With Different Contrast Media Injection Protocols Under Different Computed Tomography Machines Parameters Setting
NCT02840903 ·Status: COMPLETED
-
Evaluation of Cardiac CT Appropriateness at Second-generation 320-row CT
NCT02033837 ·Status: COMPLETED
-
Computed Tomography Coronary Angiography (CTCA) and Coronary Flow in Stenosis Analysis
NCT00921440 ·Status: COMPLETED
-
Radiation Dose From Computed Tomography Before and After Implementation of a High Pitch Dual Spiral Technique
NCT01111760 ·Status: COMPLETED
-
Study on Sex-specific, Individualized Dose Calculation of Contrast Agent in CT Examinations
NCT06965790 ·Status: RECRUITING ·Phase: NA
-
Low-dose Contrast Media for Low-kVp Abdomen CT
NCT05878665 ·Status: RECRUITING ·Phase: NA
-
Use of Electrical Impedence to Measure Lean Body Weight as a Determinant of the Dose of Contrast Media for Abdominal CT
NCT02170688 ·Status: COMPLETED ·Phase: PHASE4
-
The Impact of Oral Contrast in Multidetector CT of the Abdomen and Pelvis on Radiologist Confidence
NCT01655550 ·Status: UNKNOWN ·Phase: NA
-
Risk Factors and Computed Tomography Findings in COVID-19.
NCT04577105 ·Status: COMPLETED
-
Rapid Examination of Acute CT
NCT06507124 ·Status: COMPLETED ·Phase: NA
-
A Randomized, Controlled Trial to Evaluate CT Image Quality Lumentin® 44
NCT03326518 ·Status: TERMINATED ·Phase: PHASE2