Evaluation of Physiological Responses at the Anterior Surface of Two (Hydrophobic Acrylic) Intraocular Lens Models
NCT04230629 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2021-03-09
Summary
On the day of surgery, the the eye with astigmatism of at least 0.75dpt receives a Vivinex XY1A , HOYA Surgical Optics GmbH and the second eye to be operated receives an XY1, HOYA Surgical Optics GmbH.
A complete biomicroscopic examination and visual acuity testing using autorefractometer, will be performed 1 week (7-14days), 6 weeks (30-60days) and 5 month (4-6months) postoperatively.
Conditions
- Age Related Cataracts
Interventions
- DEVICE
-
Vivinex XY1
Implantation of an intraocular lens Hoya Vivinex XY1
- DEVICE
-
Vivinex XY1A
Implantation of an intraocular lens Hoya Vivinex XY1A
Sponsors & Collaborators
-
Medical University of Vienna
lead OTHER
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-03-15
- Primary Completion
- 2021-12-30
- Completion
- 2022-06-30
More Related Trials
-
A Prospective, Randomized, Subject and Vision-assessor Masked, Multicenter Study Comparing Bilateral Clareon PanOptix, Bilateral Clareon PanOptix Pro, and Mixed Clareon PanOptix Pro/Vivity Intraocular Lens Implantation in Cataract Subjects
NCT06922084 ·Status: RECRUITING ·Phase: PHASE4
-
Intraindividual Comparison of EMO IOLs
NCT05822089 ·Status: RECRUITING ·Phase: NA
-
Rotation of Hydrophobic Acrylic Lenses - Rayner RA0800C & Alcon Clareon & Hoya Nanex & Hoya Vivinex XY1-EM & RayOne EMV Toric & PODEYE Toric
NCT03803852 ·Status: RECRUITING ·Phase: NA
-
Pseudoaccommodation of the Light Adjustable Lens: A Comparitive Study
NCT07176429 ·Status: ENROLLING_BY_INVITATION
-
Performance of Two Intraocular Lenses With Extended Depth of Vision
NCT05194150 ·Status: UNKNOWN ·Phase: NA
-
Visual Performance With Clareon® Vivity® Intraocular Lenses (IOLs)
NCT06784063 ·Status: COMPLETED ·Phase: NA
-
Visual Acuity Outcome Differences Between the Alcon Vivity Toric IOL and RxSight LAL+
NCT06574646 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Reading Performance in Patients With Acrysof IQ Vivity Versus Acrysof IQ
NCT05194657 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Three Swept-source Optical Coherence Biometry Devices in Long and Short Eyes
NCT05232214 ·Status: UNKNOWN
-
Posterior Capsule Opacification Development With Two Different Intraocular Lenses
NCT01734343 ·Status: COMPLETED ·Phase: NA
-
Clinical Outcomes of Clareon Vivity Intraocular Lens With Mini-Monovision Approach
NCT05821101 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Vivinex Impress XY1-EM vs RayOne EMV
NCT06891092 ·Status: RECRUITING ·Phase: NA
-
Visual Outcomes and Quality of Life After Vivity EDOF IOL Implantation in Early-Stage Keratoconus
NCT07338708 ·Status: COMPLETED ·Phase: NA
-
Clinical Investigation of the AcrySof IQ Vivity Extended Vision Intraocular Lens (IOL)
NCT04098367 ·Status: COMPLETED ·Phase: NA
-
Visual Outcomes of Vivity in Patients With High Axial Length
NCT05210569 ·Status: COMPLETED
-
Evaluation of Visual Function After Bilateral Implantation of EDOF IOLs
NCT05335408 ·Status: COMPLETED ·Phase: NA
-
Agreement and Accuracy of Different Devices for Biometry Measurements in Patients With Cataract
NCT04323358 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Two Non-diffractive Enhanced Monofocal Intraocular Lenses
NCT06345820 ·Status: RECRUITING ·Phase: NA
-
Visual Acuity After the Combined Binocular Implantation of +2.75 Diopters and +3.25 Diopters Tecnis Multifocal Intraocular Lenses.
NCT02633072 ·Status: COMPLETED ·Phase: PHASE4
-
Comparative Study of 2 Multifocal Intraocular Lenses in Heidelberg
NCT06327347 ·Status: RECRUITING ·Phase: NA
-
Performance of Two Hydrophobic IOLs
NCT05639049 ·Status: UNKNOWN ·Phase: NA
-
Clinical Study to Investigate Visual Performance of a Hydrophobic Monofocal IOL After Bilateral Implantation
NCT03423524 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Clareon Vivity/Vivity Toric
NCT05852470 ·Status: COMPLETED ·Phase: NA
-
Assessment of Visual Function and Optics in Intraocular Lenses
NCT01654159 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Pseudophakic Accommodation
NCT00716339 ·Status: COMPLETED ·Phase: NA