Summary

This trial investigates operator radiation doses when performing standardized procedures using two different means of radiation protection, namely conventional lead shield and apron versus suspended protection system (Zero-Gravity, ZG). The performed procedure is standard endovascular aortic repair (EVAR). The hypothesis is that ZG offers superior protection for the operator.

Conditions

  • Radiation Exposure

Interventions

DEVICE

Zero-Gravity

Free-floating, suspended personal radiation protection

DEVICE

Conventional radiation protection

Standard lead shields and aprons

Sponsors & Collaborators

  • Helsinki University Central Hospital

    lead OTHER

Principal Investigators

  • Maarit Venermo, MD, PhD · University of Helsinki

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2019-09-02
Primary Completion
2021-03-31
Completion
2021-04-30

Countries

  • Finland

Study Locations