Beacon Sensors and Telerehabilitation for Low Vision
NCT04066075 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 61
Last updated 2025-06-29
Summary
The successful application of magnification devices for reading and daily tasks is predicated on their correct use by individuals with low vision (LV). Barriers related to transportation, geography, and/or co-morbidities often limit LV patients' ability to attend several in-office training sessions as part of low vision rehabilitation (LVR) to optimize visual function with magnification devices. A promising solution is real-time videoconferencing to provide telerehabilitation, involving remotely delivered LVR services by a LVR provider in office to a patient at home. Telerehabilitation for LV appears to be feasible and acceptable by both patients and LVR providers, yet there are no published outcomes on the potential to improve patients' visual functioning. Another key issue in LVR is the need for an effective system to continually assess how patients are functioning at home. Ideally this would involve a non-invasive, efficient method to assess when magnifier device abandonment occurs, so that a timely telerehabilitation session can be initiated. Small Bluetooth low energy beacon sensors attached to the handles of magnifiers can collect real-time data regarding minute-to-minute environmental changes, which might serve as an indicator of magnifier use by LV patients at home. Specifically, the investigators propose to assess the potential for telerehabilitation to enhance visual function by providing remotely-delivered LVR training to use magnification devices. Following one in-office training session for new magnification device(s), the investigators aim to determine if there is additional gain in visual functioning by randomizing subjects to telerehabilitation or additional in-office LVR (active control). Participants will be assessed before and after two consecutive periods: (1) one month after a single LVR training session, followed by (2) up to three LVR sessions over a three month period either via telerehabilitation in the participants' homes or LVR in-office. The investigators will determine which patient characteristics and/or magnification devices are most likely to benefit from telerehabilitation. The investigators will also determine whether data from Bluetooth beacon sensors are valid indicators of hand-held magnifier device usage by LV patients at home. The study investigators will deploy Estimote Sticker beacon sensors to subjects randomized to telerehabilitation or additional in-office LVR during the same study period. It is anticipated that beacon sensors will measure significantly increased temperature and/or motion when placed on the part of the magnification device held by LV patients while performing daily activities. Beacon sensor data will determine if it is feasible to assess when magnification devices are used, and if the frequency of magnifier use changes following telerehabilitation or in-office LVR. This work will evaluate and refine the procedures for implementing these technologies for LVR, in order to develop future randomized controlled trial protocols. The investigators envision that telerehabilitation and beacon sensors could improve LV patient outcomes by providing follow-up LVR services in a more efficient and timely manner.
Conditions
- Low Vision
Interventions
- BEHAVIORAL
-
Low Vision Rehabilitation
Low Vision Rehabilitation for use of magnification devices for near reading tasks
Sponsors & Collaborators
-
National Eye Institute (NEI)
collaborator NIH -
American Academy of Optometry
collaborator OTHER -
Southern California College of Optometry at Marshall B. Ketchum University
collaborator OTHER -
New England College of Optometry
collaborator OTHER -
University of Nebraska
collaborator OTHER -
Mid Michigan Health Centers
collaborator OTHER -
Eye Vision Associates
collaborator UNKNOWN -
See What You Miss Optometry
collaborator UNKNOWN -
Low Vision Services, PLC
collaborator UNKNOWN -
Pacific Vision Foundation
collaborator OTHER -
Boston University
collaborator OTHER -
University of California, Los Angeles
lead OTHER
Principal Investigators
-
Ava K Bittner, OD, PhD · UCLA Stein Eye Institute
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-10-10
- Primary Completion
- 2023-11-28
- Completion
- 2023-11-28
Countries
- United States
Study Locations
More Related Trials
-
Efficacy of Enhancing Low Vision Mobility Thru Visual Training in Virtual World
NCT02310880 ·Status: COMPLETED
-
Factors in Learning And Plasticity: Healthy Vision
NCT05439759 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Problem Solving Training and Low Vision Rehabilitation
NCT00545220 ·Status: COMPLETED ·Phase: NA
-
Use of Self-management Group to Improve Quality of Life in Patients With Low Vision
NCT03046485 ·Status: WITHDRAWN ·Phase: NA
-
Functional Vision in TBI
NCT01214070 ·Status: TERMINATED ·Phase: PHASE4
-
Evaluation of Eye Movement Tracking Systems for Visual Rehabilitation
NCT00013429 ·Status: COMPLETED ·Phase: PHASE2
-
Scotoma Perimetry Oculomotor Training
NCT05456581 ·Status: COMPLETED ·Phase: NA
-
Remapping Text in Sentence and Word Tasks to Aid Reading With Central Vision Loss
NCT07216924 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Vestibular Rehabilitation Incorporated With Optokinetic Stimulation in Peripheral Vestibular Dysfunction Patients
NCT05002374 ·Status: RECRUITING ·Phase: NA
-
Biofeedback for Hemianopia Vision Rehabilitation
NCT05397873 ·Status: RECRUITING ·Phase: NA
-
Feasibility and Efficacy of Assisstive Tactile and Auditory Communicating Devices
NCT03174314 ·Status: COMPLETED ·Phase: NA
-
Effect of Visual Retraining on Visual Loss Following Visual Cortical Damage
NCT05098236 ·Status: COMPLETED ·Phase: NA
-
Visual Remapping to Aid Reading With Field Loss
NCT03848663 ·Status: RECRUITING ·Phase: NA
-
Rehabilitation For Acquired Visual Field Defects: Development Of A Bottom-Up Approach
NCT01730560 ·Status: COMPLETED ·Phase: NA
-
Visual Rehabilitation of Patients With Myopic Maculopathy
NCT01244074 ·Status: COMPLETED ·Phase: NA
-
Visual Rehabilitation After Occipital Stroke
NCT04798924 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparative Efficacy of Saccadic and Biofeedback Training in Homonymous Hemianopia
NCT06638619 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Training Oculo-motor Control to Improve Vision When Using a Preferred Retinal Locus
NCT05637385 ·Status: UNKNOWN ·Phase: NA
-
Visual Restoration for Hemianopia
NCT03350919 ·Status: COMPLETED ·Phase: NA
-
VA Low Vision Intervention Trial
NCT00223756 ·Status: COMPLETED ·Phase: NA
-
Feasibility Tests for Various Prism Configurations for Visual Field Loss
NCT04424979 ·Status: RECRUITING ·Phase: NA
-
Environmental Localization Mapping and Guidance for Visual Prosthesis Users
NCT04359108 ·Status: COMPLETED ·Phase: NA
-
Effect of Visual Retraining After Stroke
NCT06121219 ·Status: RECRUITING ·Phase: NA
-
Factors in Learning And Plasticity: Macular Degeneration
NCT05454124 ·Status: RECRUITING ·Phase: NA
-
Collision Warning Device for Blind and Visually Impaired
NCT03057496 ·Status: COMPLETED ·Phase: NA