Ripple Mapping Guided Ablation of Ischaemic Ventricular Tachycardia.
NCT03997201 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2022-07-21
Summary
The Ripple VT-1 Study is a prospective clinical trial that aims to investigate if catheter ablation of ventricular tachycardia in patients with ischaemic heart disease can be effectively performed using Ripple Mapping.
Conditions
- Ventricular Tachycardia
- Ischemic Heart Disease
Interventions
- PROCEDURE
-
Ripple Mapping guided ischaemic VT ablation
Endocardial mapping of the ventricle performed with Ripple Mapping (CARTO3v6, Biosense Webster Inc). Ablation (SmarTouch Thermocool Catheter, Biosense Webster Inc) delivered to areas of abnormal "late" electrical activity within ventricular scar tissue.
Sponsors & Collaborators
-
Barts & The London NHS Trust
collaborator OTHER -
Papworth Hospital NHS Foundation Trust
collaborator OTHER_GOV -
Nottingham University Hospitals NHS Trust
collaborator OTHER -
Newcastle-upon-Tyne Hospitals NHS Trust
collaborator OTHER -
Hospital de Santa Maria, Portugal
collaborator OTHER -
Imperial College Healthcare NHS Trust
lead OTHER
Principal Investigators
-
Prapa Kanagaratnam · Imperial College Healthcare NHS Trust
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-04-18
- Primary Completion
- 2022-04-30
- Completion
- 2022-06-30
Countries
- United Kingdom
Study Locations
More Related Trials
-
Catheter Ablation Versus Radio-Ablation for Ventricular Tachycardia: a Randomized Controlled Trial
NCT05047198 ·Status: RECRUITING ·Phase: PHASE3
-
Cardiovascular Magnetic Resonance-Guided Radiofrequency-Ablation for Atrial Flutter II
NCT03078985 ·Status: COMPLETED ·Phase: NA
-
Atrial Flutter Ablation With Contact Therapy Cool Path Ablation System Along With EnSite Velocity Contact System
NCT01401361 ·Status: COMPLETED ·Phase: PHASE3
-
Cryotherapy Versus Radiofrequency Catheter Ablation Research Program
NCT03816033 ·Status: UNKNOWN ·Phase: NA
-
Cryoablation as Standard Treatment of Atrial Flutter
NCT01604369 ·Status: COMPLETED ·Phase: NA
-
Catheter Ablation as the First Line Therapy for Typical Atrial Flutter
NCT00213408 ·Status: TERMINATED ·Phase: PHASE4
-
Complex Arrhythmia Registry
NCT07024927 ·Status: NOT_YET_RECRUITING
-
Typical Flutter Ablation:A Comparison of 4 mm Versus 2 mm Irrigated cathéters
NCT00750711 ·Status: UNKNOWN ·Phase: NA
-
Randomized Study of Radiofrequency- vs. Cryo-Ablation for Typical Isthmus-Dependent Atrial Flutter
NCT00196170 ·Status: UNKNOWN ·Phase: PHASE4
-
Rate or Rhythm Control in CRT: the RHYTHMIC Study
NCT04664686 ·Status: RECRUITING ·Phase: NA
-
Remote Magnetic Navigation For Cavotricuspid Isthmus Ablation
NCT00560872 ·Status: COMPLETED ·Phase: NA
-
Biatrial Global High-density Electroanatomical Mapping of Atrial Fibrillation
NCT03812601 ·Status: COMPLETED
-
Fluoroscopic, Contact Force and Local Impedance With Ultra-high Density Mapping Guided Radiofrequency Ablation Comparison for cavoTricuspid Isthmus dependenT Atrial fluttER: the FLUTTER Study
NCT04434599 ·Status: WITHDRAWN ·Phase: NA
-
Trial to Evaluate the Efficacy and Safety of Substrate Ablation of Monomorphic Ventricular Tachycardia
NCT03734562 ·Status: COMPLETED ·Phase: NA
-
Left Atrial FLUTter: a Comparison of Ablation Guided by High-density MApping and Empirical LINEar Ablation.
NCT05063032 ·Status: RECRUITING ·Phase: NA
-
Efficacy of Transcatheter Radiofrequency Ablation of Atrial Flutter With Standard Irrigated Catheter With Flexible Tip
NCT01262443 ·Status: COMPLETED ·Phase: NA
-
Cardiovascular Magnetic Resonance-Guided Radiofrequency-Ablation for Atrial Flutter
NCT02699034 ·Status: TERMINATED ·Phase: NA
-
Does Timing of VT Ablation Affect Prognosis in Patients With an Implantable Cardioverter-defibrillator?
NCT01547208 ·Status: UNKNOWN ·Phase: NA
-
Fibrillatory Factor in Ventricular Tachycardia
NCT01974908 ·Status: UNKNOWN ·Phase: NA
-
Long-term outcomeS of cavotrIcuspid isthMus-dePendent fLuttEr Ablation: Single vs Double Catheter Procedure
NCT04472936 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of Therapy™ Cool Path™ Duo Cardiac Ablation System for the Treatment of Typical Atrial Flutter (AFL)
NCT00984204 ·Status: COMPLETED ·Phase: PHASE3
-
Typical Atrial Flutter, Ablation Index and Point by Point Ablation
NCT03867266 ·Status: UNKNOWN
-
Maximum Targeted Ablation of Atrial Flutter
NCT00491010 ·Status: UNKNOWN ·Phase: PHASE4
-
Functional ElectroAnatomiC Isochronal Late Activation Mapping for Empiric VT Ablation Trial
NCT06931821 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Safety and Efficacy of the CryoCor™ Cardiac Cryoablation System for the Treatment of Atrial Flutter
NCT00113178 ·Status: COMPLETED ·Phase: PHASE3