Long-term outcomeS of cavotrIcuspid isthMus-dePendent fLuttEr Ablation: Single vs Double Catheter Procedure
NCT04472936 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 253
Last updated 2023-08-30
Summary
Catheter ablation is recommended as first-line therapy for most patients with typical atrial flutter. The most common approach is to create an ablation line across the cavotricuspid isthmus (CTI). Traditionally, atrial flutter ablation has been performed with a conventional approach using two catheters, an ablation catheter and a duodecapolar catheter that is placed at the level of the tricuspid annulus to confirm the CTI block. Recently, a single catheter approach has been described using the behavior of PR interval change during differential pacing over the ablation line to prove CTI block. This prospective, randomized, multicenter study analyzes the effectivity of a single catheter approach compared with conventional approach in terms of clinical outcomes.
Conditions
- Atrial Flutter
Interventions
- PROCEDURE
-
Single catheter approach
Single venous femoral access will be obtained and the ablation will be performed similar to Group A. After the ablation line is over, we will confirm CTI block using the PRI. During atrial pacing (10 V, 1.5 ms) at a stable cycle length (range 500-700ms) from the tip of the ablation catheter with a sweep speed of 300mm/s, the ablation catheter will be placed first at 5 o'clock (medial to CTI line), then at 7 o'clock (lateral to CTI line), and finally at 9 o'clock position, and the corresponding PRIs will be measured for each pacing site. CTI block is assumed when: (i) the PRI at 7 o'clock is \>80ms longer than that at pacing sites of 5, and (ii) the PRI at 9 o'clock is shorter than the PRI at 7 o'clock.
- PROCEDURE
-
Traditional approach
Double venous femoral access will be obtained. A duodecapolar catheter will be positioned in the right atrium around the tricuspid valve annulus (TVA) to record activation sequence around the tricuspid annulus. An ablation catheter will be positioned using fluoroscopic guidance in the central CTI, 6 o'clock in a left anterior oblique view. The distal ablation electrode position will then be adjusted toward or away from the TVA, based on the ratio of atrial and ventricular electrogram amplitudes with an optimal ratio of 1:2 or 1:4 at the TVA. After the ablation catheter is positioned, it will be very slowly withdrawn during ablation toward the inferior vena cava while radiofrequency energy is applied continuously. CTI block will be evaluated after ablation by determining the right atrial activation sequence during pacing from the low lateral right atrium and coronary sinus ostium.
Sponsors & Collaborators
-
Centro Medico Teknon
lead OTHER
Principal Investigators
-
Antonio Berruezo, MD, PhD · Centro Medico Teknon
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-07-16
- Primary Completion
- 2022-09-30
- Completion
- 2022-11-30
Countries
- Spain
Study Locations
More Related Trials
-
Catheter Ablation as the First Line Therapy for Typical Atrial Flutter
NCT00213408 ·Status: TERMINATED ·Phase: PHASE4
-
Cryoablation as Standard Treatment of Atrial Flutter
NCT01604369 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Transcatheter Radiofrequency Ablation of Atrial Flutter With Standard Irrigated Catheter With Flexible Tip
NCT01262443 ·Status: COMPLETED ·Phase: NA
-
Thermocool SF Catheter Versus Thermocool Catheter in Isthmus-dependent Atrial Flutter Ablation
NCT02088489 ·Status: COMPLETED ·Phase: PHASE3
-
Typical Atrial Flutter, Ablation Index and Point by Point Ablation
NCT03867266 ·Status: UNKNOWN
-
Therapy of Atrial Flutter by Afib Ablation
NCT02051621 ·Status: UNKNOWN ·Phase: NA
-
Cryoballoon Pulmonary Venous Isolation in Patients Referred for Typical Atrial Flutter Ablation
NCT01521988 ·Status: COMPLETED ·Phase: NA
-
Left Atrial FLUTter: a Comparison of Ablation Guided by High-density MApping and Empirical LINEar Ablation.
NCT05063032 ·Status: RECRUITING ·Phase: NA
-
Remote Magnetic Navigation For Cavotricuspid Isthmus Ablation
NCT00560872 ·Status: COMPLETED ·Phase: NA
-
Ablation of Typical Right Atrial Flutter
NCT05755074 ·Status: RECRUITING ·Phase: NA
-
Identification of Risk Factors for Atrial Fibrillation After Ablation of an Atrial Flutter by Radiofrequency of the Cavotricuspid Isthmus.
NCT03919097 ·Status: COMPLETED
-
Typical Flutter Ablation:A Comparison of 4 mm Versus 2 mm Irrigated cathéters
NCT00750711 ·Status: UNKNOWN ·Phase: NA
-
Impact Of Different Ablation Approaches on Outcome In Coexistent Atrial Fibrillation and Flutter
NCT01439386 ·Status: COMPLETED ·Phase: PHASE3
-
Intracardiac Echocardiography in Atrial Flutter Ablation
NCT02426710 ·Status: COMPLETED ·Phase: PHASE3
-
Ablation Index in Standard vs. High Power Radiofrequency Ablation for Typical Atrial Flutter: A Randomized Study (AITAF)
NCT06406686 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Maximum Targeted Ablation of Atrial Flutter
NCT00491010 ·Status: UNKNOWN ·Phase: PHASE4
-
Safety and Efficacy of Catheter Ablation of Idiopathic Ventricular Arrhythmias Arising From Cardiac Outflow Tracts
NCT03258112 ·Status: WITHDRAWN ·Phase: NA
-
Catheter Versus Thoracoscopic Surgical Ablation Strategy in Persistent Atrial Fibrillation
NCT01385358 ·Status: UNKNOWN ·Phase: NA
-
Cryoablation in Patients With Atrial Flutter
NCT01563848 ·Status: UNKNOWN ·Phase: PHASE2
-
Atrial Fibrillation Ablation: Radiofrequency or Cryoablation?
NCT03774550 ·Status: COMPLETED
-
Randomised Prospective Trial Comparing Contact Force and Non-contact Force Guided Catheter Ablation for Cavotricuspid Isthmus Dependent Atrial Flutter
NCT02825498 ·Status: UNKNOWN ·Phase: NA
-
CTI Ablation Guided by Omnipolar Wave Speed and Voltage Maps to Diminish RF and Fluoroscopy Times
NCT05709795 ·Status: RECRUITING ·Phase: NA
-
Catheter Ablation Versus Thoracoscopic Ablation to Patients With Permanent Atrial Fibrillation
NCT00296166 ·Status: TERMINATED ·Phase: NA
-
Atrial Flutter Ablation With Contact Therapy Cool Path Ablation System Along With EnSite Velocity Contact System
NCT01401361 ·Status: COMPLETED ·Phase: PHASE3
-
The Use of Remote Magnetic Navigation in Catheter Ablation of Heart Arrythmia
NCT00524602 ·Status: UNKNOWN ·Phase: NA