Effects of Echo-optimization of Left Ventricular Assist Devices on Functional Capacity (VAFRACT)
NCT03937570 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 27
Last updated 2021-11-02
Summary
After the implantation of a left ventricular assist device (LVAD), many patients continue to experience exercise intolerance. LVAD echo guided optimization (EO) determines a more favorable hemodynamic profile and could provide an improvement on functional capacity (FC). VAFRACT is a prospective randomized trial to evaluate the additional benefit of an EO approach on FC, measured by cardiopulmonary exercise test (CPET), in LVAD optimization free population.
Conditions
Interventions
- DEVICE
-
echo-optimization
LVAD echo-optimization consists of routine comprehensive transthoracic echocardiography at the baseline speed setting, followed by stepwise incremental adjustments to the LVAD speed (revolutions per minute: rpm), with collection of prespecified echocardiographic parameters at each new speed (eg, left ventricle end-diastolic diameter, interventricular septal position, aortic valve opening frequency/duration, tricuspid and/or mitral regurgitation severity). The optimal velocity is defined as the one that allows an intermittent aortic valve opening and a neutral position of the interventricular septum without increasing aortic or tricuspid regurgitation, associated or not to a dilatation of the right ventricle. The recommended speed range varies according to the indications given in the data sheet for each specific device.
Sponsors & Collaborators
-
Universita di Verona
lead OTHER
Principal Investigators
-
MARZIA LILLIU, MD
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-02-08
- Primary Completion
- 2019-12-30
- Completion
- 2020-08-31
- FDA Device
- Yes
Countries
- Italy
Study Locations
More Related Trials
-
Diagnosing Heart Failure With Preserved Ejection Fraction in Patients With Unexplained Dyspnea (Diagnose-HFpEF)
NCT04688905 ·Status: ACTIVE_NOT_RECRUITING
-
Left Ventricular Dysfunction in Critically Ill Patients
NCT03787810 ·Status: COMPLETED
-
Left Atrial Volume Index in Asymptomatic Aortic Stenosis
NCT02395107 ·Status: COMPLETED
-
REVADE : Right Ventricular Function and Exercise in Left Ventricular Assist Device Patients : Echocardiographic Study
NCT02067455 ·Status: COMPLETED ·Phase: NA
-
Mechanisms of Right Ventricular Adaptation in Patients With Heart Failure With Preserved Ejection Fraction
NCT04154657 ·Status: UNKNOWN ·Phase: NA
-
Sevoflurane Effect on Left Atrial Performance: A Transoesophageal Echocardiographic Study
NCT03999463 ·Status: COMPLETED
-
Cardiac Hemodynamics During Left Ventricular Assist
NCT06115096 ·Status: RECRUITING
-
Comparison Endotracheal Cardiac Output Monitor (ECOM) to a Standard Device in Measuring Heart Blood Volume
NCT00883857 ·Status: COMPLETED
-
Left Ventricular Volume and Ejection Fraction: Validation of Real Time 3 Dimensional Transesophageal Echocardiography
NCT01734174 ·Status: WITHDRAWN
-
Heart Failure Ventricular Pressure Time Profile
NCT02791074 ·Status: COMPLETED
-
Evaluation of Left Ventricular Volumes by Real-Time 3-Dimensional Echocardiography
NCT00001740 ·Status: COMPLETED
-
Physiology of Unloading VA ECMO Trial
NCT06336655 ·Status: RECRUITING ·Phase: PHASE2
-
Heart Failure Monitoring With Eko Electronic Stethoscopes
NCT04404452 ·Status: TERMINATED
-
Optimizing Continuous-flow Left Ventricular Assist Device Settings and Identification of Pump Malfunction - A Comparative Study of Echocardiography and Invasive Hemodynamics
NCT01851889 ·Status: COMPLETED
-
Establishing Physiologic Outcomes for Ventricular Unloading on VA ECMO
NCT05658276 ·Status: WITHDRAWN
-
Exercise Pulmonary Transit Time
NCT04336995 ·Status: COMPLETED ·Phase: PHASE4
-
Impact of Intraventricular Electrical Activation in Resynchronization Therapy
NCT01270646 ·Status: COMPLETED ·Phase: PHASE2
-
Evaluation of Left Ventricular Function After Treatment of Diabetic Foot Ulcers Using Longitudinal Strain Echocardiography
NCT06747377 ·Status: NOT_YET_RECRUITING
-
Mitral Valve Reconstruction in Chronic Heart Failure (CHF): Identification of Predictors for a Successful Therapy
NCT00348829 ·Status: TERMINATED ·Phase: PHASE2
-
Low Ejection Fraction in Single Lead ECG
NCT05010655 ·Status: COMPLETED
-
Detection of Heart Conditions With Single Lead ECG Using Artificial Intelligence
NCT04400435 ·Status: COMPLETED
-
Detection of Reduced Left Ventricular Ejection Fraction With Three-Lead ECG Using Artificial Intelligence
NCT07270692 ·Status: RECRUITING
-
Diastolic Dysfunction PPCM in Patients With Documented Left Ventricular Systolic Function Recovery
NCT04143997 ·Status: WITHDRAWN
-
Effects of Acutely Elevated Afterload on Left Ventricular Contractility and Relaxation
NCT02751853 ·Status: TERMINATED ·Phase: NA
-
Use of POC Pocket Ultrasound in the Estimation of Left and Right Atrial Pressures
NCT03897647 ·Status: WITHDRAWN ·Phase: NA