Artificial Intelligence in Echocardiography
NCT03936413 · Status: WITHDRAWN · Phase: NA · Type: INTERVENTIONAL
Last updated 2021-12-17
Summary
The goal of this study is to determine whether the Bay Labs artificial intelligence (AI) system can be used by minimally trained operators to obtain diagnostic quality echocardiographic images.
Conditions
Interventions
- DEVICE
-
Bay Labs EchoGPS Echcoardiogram
An echocardiogram will be performed in this arm using the Bay Labs EchoGPS. The Bay Labs EchoGPS system is an ultrasound system which uses the techniques of computer vision to analyze echocardiography images in real time. It then provides feedback to the user to optimize the images, and once they meet a specific level of quality it automatically records the images.
- DEVICE
-
Native Terason Echocardiogram
An echocardiogram will be performed in this arm using a native Terason echocardiography system. This system will not have any artificial intelligence assistance in image optimization or selection.
Sponsors & Collaborators
-
Caption Health, Inc.
collaborator INDUSTRY -
New York Presbyterian Hospital
lead OTHER
Principal Investigators
-
Kerry A Esquitin, MD · Columbia University
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SEQUENTIAL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-01-13
- Primary Completion
- 2020-01-13
- Completion
- 2020-01-13
- FDA Device
- Yes
More Related Trials
-
Safety and Efficacy Study of AI LVEF
NCT05140642 ·Status: COMPLETED ·Phase: NA
-
Deep Learning Enhanced Detection of Aortic Stenosis - The DETECT-AS-Diagnostic Study
NCT06749145 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
AI Assessment of Low-Gradient Aortic Stenosis Severity Based on Echocardiography
NCT07144189 ·Status: RECRUITING
-
CAPTION AI to Minimize Risk of COVID Exposure
NCT04336774 ·Status: WITHDRAWN ·Phase: NA
-
Artificial Intelligence-assisted Diagnosis and Prognostication in Low Ejection Fraction Using Electrocardiograms
NCT05117970 ·Status: COMPLETED ·Phase: NA
-
Artificial Intelligence for Improved Echocardiography
NCT04580095 ·Status: COMPLETED ·Phase: NA
-
Detection of Heart Conditions With Single Lead ECG Using Artificial Intelligence
NCT04400435 ·Status: COMPLETED
-
ENABLE-HCM - AI-ENabled Echocardiography With Ultrasound Beyond the Echo Lab for Better HCM Imaging and Expanded Access
NCT07155434 ·Status: TERMINATED
-
Validation of an Artificial Intelligence Algorithm Identifying Echocardiographic Reference Views. Ultrasound - Cardiac Acquisition Guide
NCT05265585 ·Status: COMPLETED
-
AI-Enabled Diagnosis and Prognosis of Hypertrophic Cardiomyopathy
NCT07263204 ·Status: RECRUITING
-
Assessment of Left Ventricular Filling Pressure by Applying Artificial Intelligence Algorithms to Left Atrial Speckle-tracking Echocardiography
NCT05768698 ·Status: RECRUITING
-
Artificial Intelligence (AI) Analysis of Synchronized Phonocardiography (PCG) and Electrocardiogram(ECG)
NCT06009718 ·Status: RECRUITING
-
Assessment of Diagnostic Adequacy of AI-assisted Point-of-Care Echocardiography Among Anesthesiology Trainees
NCT06548373 ·Status: ACTIVE_NOT_RECRUITING
-
Ventricular Remodeling In Patients With Aortic Stenosis Assessed Echocardiography
NCT00774657 ·Status: WITHDRAWN
-
A Multicenter Pragmatic Implementation Study of ECG-AI-Based Clinical Decision Support Software to Identify Low LVEF
NCT05867407 ·Status: TERMINATED ·Phase: NA
-
Interactive Guided Ultrasound Examinations Done by Non-experts of Ultrasound Imaging
NCT03642730 ·Status: COMPLETED ·Phase: NA
-
ECG Low Ejection Fraction Detection and Guiding in AI Navigated Treatment Era
NCT06968533 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Efficacy of AI EF Screening by Using Smartphone Application Recorded PLAX View Cardiac Ultrasound Video Clips
NCT06330103 ·Status: COMPLETED ·Phase: NA
-
Optimization of an Automated Ultrasound Cardiac Guidance Tool
NCT04981444 ·Status: COMPLETED
-
Data Collection for Echocardiography-Based Software Assessment
NCT07126600 ·Status: COMPLETED
-
Fetal Heart Ultrasound Suspicious Radiographic Finding Identification - Reader Study
NCT06392555 ·Status: COMPLETED
-
Feasibility of AI-based Heart Function Prediction Model Using CXR
NCT04996381 ·Status: COMPLETED
-
Safety and Efficacy Study of AI Wall Thickness Measurement (EchoNet-LVH-RCT)
NCT05791227 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
LV Endocardial CRT for Patients With Intermediate QRS Width
NCT03573427 ·Status: WITHDRAWN
-
Intracardiac Versus Transesophageal Echocardiographic Guidance for Left Atrial Appendage Occlusion
NCT06348394 ·Status: RECRUITING ·Phase: NA