Ultrasound Evaluation of the Jugular Venous Pulse (US-JVP)
NCT03917368 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 300
Last updated 2019-04-17
Summary
The jugular venous pulse (JVP) reflects changes in the right atrial pressure and its evaluation can be useful in managing many emergency conditions for guiding the fluid administration as well as in the diagnosis and/or prognosis of many heart and lung diseases. The present study aims: i) To validate a novel ultrasonographic (US) technique for obtaining the JVP from a high-resolution B-mode sonograms sequence, recording the changes of the cross-sectional area (CSA) of the internal jugular veins (IJV) over the cardiac cycle; ii) To develop physical and mathematical models capable of providing an indirect estimate of central venous pressure (CVP) from the changes in IJV-CSA acquired through the US investigation, and iii) To test the transferability of the novel US-JVP technique in a clinical setting.
Conditions
- Cardiovascular Diseases
- Neurovascular Disorders
- Emergencies
Interventions
- OTHER
-
Ultrasound scan of the internal jugular veins
Participants, lying at their hospital bed, will maintain their head in a fixed position on the longitudinal axis, while an operator gently places a linear probe L12-RS (7.5-11 MHz), smeared with gel, on one side of the neck, at the middle level. A 15-sec video clip of the ultrasound images will be recorded. This procedure will be repeated on the other side of the neck. In addition, three electrodes will be placed on participants' chests and connected to the ultrasound system for simultaneously measuring the ECG signal.
Sponsors & Collaborators
-
S. Anna Hospital
lead OTHER
Principal Investigators
-
Paolo Zamboni, Prof · University Hospital of Ferrara, Italy
Study Design
- Allocation
- NA
- Purpose
- OTHER
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2016-09-16
- Primary Completion
- 2019-10-31
- Completion
- 2020-05-31
Countries
- Italy
Study Locations
More Related Trials
-
Performance Evaluation of Clinical Ultrasound in Management of Acute Pulmonary Edema in Elderly Patient
NCT02638350 ·Status: COMPLETED ·Phase: NA
-
Volume Responsiveness By Ultrasound Of Carotid Blood Flow In Patients With Cardiogenic Shock
NCT05271227 ·Status: COMPLETED
-
HF vs NIV in Acute Cardiogenic Pulmonary Edema
NCT05989139 ·Status: RECRUITING ·Phase: NA
-
Usefulness of an Ultraportative Ultrasound Device in the Management of Intra Hospital Emergencies
NCT02967809 ·Status: COMPLETED
-
Acute DYSPnea in the Emergency Department: Diagnostic Value of Point-of-care UltraSound
NCT07324980 ·Status: RECRUITING
-
Impact of Immediate Point-of-Care Ultrasound on Patients With Cardiopulmonary Symptoms in the Emergency Department
NCT02861508 ·Status: COMPLETED ·Phase: NA
-
Peripheral Venous Pressure Variation and Fluid Responsiveness
NCT05131516 ·Status: COMPLETED
-
Predictive Value of Venous Excess Ultrasound Score in Management of Cardiorenal Patients
NCT05368766 ·Status: UNKNOWN
-
Point-of-care Ultrasound Interest in Dyspneic Emergency Department Patients: an Observational Bicentric Study
NCT04327882 ·Status: UNKNOWN
-
Diaphragm Ultrasound to Predict Weaning Outcomes in Mechanically Ventilated Patients
NCT03480828 ·Status: COMPLETED
-
Does Ultrasound Assessment for Extravascular Lung Water and IVC Measurement Affect Outcomes in Inpatient Heart Failure Management?
NCT04436718 ·Status: UNKNOWN ·Phase: NA
-
Utility of Lung Ultrasound in the Estimation of Extravascular Lung Water in Pediatric Population
NCT04417790 ·Status: COMPLETED
-
The Use of the USCOM Device in Addition to Cardiac Ultrasound in Patients Undergoing Treatment for Undifferentiated Shock
NCT01981629 ·Status: COMPLETED
-
Evaluation of LVEF by a New Automatic Evaluation Tool in a Pocket Ultrasound Scanner
NCT04366453 ·Status: COMPLETED ·Phase: NA
-
Point-of-Care Ultrasound in the Emergency Department Evaluation of Syncope
NCT01671371 ·Status: TERMINATED ·Phase: NA
-
Contribution and Reproducibility of Lung Ultrasound in the Diagnosis of Acute Heart Failure in the ED
NCT03660592 ·Status: COMPLETED
-
Tracheal, Lung, and Diaphragmatic Ultrasonography Applications for Rapid Confirmation of Endotracheal Tube Position
NCT05747248 ·Status: COMPLETED
-
Bedside Lung Ultrasonography by Nurses in Acute Dyspnea.
NCT05126940 ·Status: COMPLETED
-
Evaluation of Acute Cardiogenic Dyspnoea With Thorax Echography and Pro-BNP in the Emergency Department
NCT02122640 ·Status: COMPLETED
-
Assessment of Volume Status by Doppler US
NCT05115539 ·Status: UNKNOWN
-
Feasibility of Doppler Ultrasound for Pulse Detection in Out-of-Hospital Cardiac Arrest Patients
NCT06249893 ·Status: COMPLETED
-
Feasibility and Accuracy of an Ultrasound Algorithm for Acute Dyspnea Diagnosis in the Emergency Department
NCT03691857 ·Status: RECRUITING ·Phase: NA
-
Tissue Doppler Ultrasound During Spontaneous Breathing and Non-invasive Ventilation in the Post-extubation Period.
NCT03978221 ·Status: UNKNOWN ·Phase: NA
-
PVF in Decongestion of Heart Failure
NCT05227872 ·Status: UNKNOWN
-
Time-motion-mode Ultrasound Diaphragm Measures in Patients With Acute Respiratory Distress in Emergency Department
NCT02273687 ·Status: COMPLETED ·Phase: NA