Clinical Trial of New Hypothermic Oxygenated Perfusion System Versus Static Cold Storage

NCT03837197 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 220

Last updated 2019-09-27

No results posted yet for this study

Summary

With the present study the investigators will evaluate the benefit of end-ischemic HOPE on ECD grafts (livers and kidneys) as compared to SCS. Organs will be perfused through a recently developed machine perfusion (MP) device, from the beginning of back-table procedures till implantation, without increasing CIT. The aim of the study will be demonstrating the ability of HOPE to improve graft function and post-operative outcomes of ECD kidney and liver recipients.

Conditions

Interventions

DEVICE

Kidney-Hypothermic oxygenated

Kidney perfusion will be performed through the renal artery at 25-30 mmHg pressure. Flow, pressure and temperature will be monitored and registered on a Universal Serial Bus (USB) memory system during organ perfusion. Gas analysis of the effluent perfusate will be accomplished at the start of perfusion (T0) then every 30 minutes. Two perfusate samples will be collected at the beginning and at the end of perfusion to rule out bacterial or fungal contamination. HOPE will start by flushing the organ at low flow values (20 ml/min) with new oxygenated perfusion fluid during back-table preparation. Organ will be treated with continuous HOPE until transplant. Organ perfusion will be continuously monitored. Minimal perfusion time will be 2 hours for kidneys.

DEVICE

Liver-Hypothermic oxygenated

Liver perfusion will be performed through the portal vein at a 5 mmHg pressure. Flow, pressure and temperature will be monitored and registered on a Universal Serial Bus (USB) memory system during organ perfusion. Gas analysis of the effluent perfusate will be accomplished at the start of perfusion (T0) then every 30 minutes. Two perfusate samples will be collected at the beginning and at the end of perfusion to rule out bacterial or fungal contamination. HOPE will start by flushing the organ at low flow values (30 ml/min) with new oxygenated perfusion fluid during back-table preparation. Organ will be treated with continuous HOPE until transplant. Organ perfusion will be continuously monitored. Minimal perfusion time will be 1 hour for livers.

Sponsors & Collaborators

  • University of Bologna

    lead OTHER

Principal Investigators

  • Matteo Ravaioli, PhD · University of Bologna S.Orsola-Malpighi Hospital

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Max Age
100 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2018-12-21
Primary Completion
2019-12-31
Completion
2021-12-31

Countries

  • Italy

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03837197 on ClinicalTrials.gov