Optimizing Prosthetic and Bicycle Fit for Veterans With Transtibial Amputations
NCT03828331 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 12
Last updated 2024-12-10
Summary
Bicycling is a promising form of low-impact exercise that could prevent/treat Type 2 diabetes. However, Veterans with transtibial amputations (TTAs) may not effectively utilize bicycling for rehabilitation and exercise due to improper bike fit, socket discomfort, and/or the potential for injury. An optimized prosthetic/bicycle fit could improve comfort and reduce injury risk by decreasing asymmetries between legs, lowering metabolic costs, and improving efficiency for Veterans with TTAs during bicycling. Moreover, the use of objective prosthetic/bicycle fit guidelines would allow clinicians to facilitate shorter appointment times and fewer revisits for Veterans with TTAs. The investigators will determine the physiological and biomechanical effects of different prosthetic and bicycle configurations for Veterans with a TTA to develop optimal prosthetic/bicycle fit guidelines. The investigators hypothesize that a longer prosthetic pylon length and shorter bicycle crank arm length for the affected compared to the unaffected leg along with a pedal attachment position beneath the pylon compared to beneath the forefoot will optimize performance for Veterans with TTAs the investigators' research will integrate evidence-based guidelines to advance rehabilitation and enhance the lives of Veterans with an amputation, thus improving and restoring their function.
Conditions
- Amputation
Interventions
- OTHER
-
Prosthetic/Bicycle Configuration
The investigators will measure the biomechanics (motion, forces, and muscle activity) and metabolic rates while subjects ride using an initial bike fit and three taller pylon lengths (PL) for the affected leg (AL) in increments of 6.8 mm using a pedal attachment position (PAP) beneath the prosthetic forefoot. Then, using the optimal (most efficient) PL, the investigators will measure the biomechanics and metabolic rates while subjects ride using three shorter crank arm lengths (CALs) for the AL in decrements of 6.8 mm using a PAP beneath the prosthetic forefoot. On Day 2, the investigators will repeat the protocol of Day 1, but have riders use a PAP beneath the pylon for their AL.
Sponsors & Collaborators
-
VA Office of Research and Development
lead FED
Principal Investigators
-
Alena Grabowski, PhD BA · Rocky Mountain Regional VA Medical Center, Aurora, CO
Eligibility
- Min Age
- 18 Years
- Max Age
- 55 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2019-04-01
- Primary Completion
- 2023-08-31
- Completion
- 2023-08-31
Countries
- United States
Study Locations
More Related Trials
-
Bioimpedance as a Diagnostic Tool for Assessing the Need for Socket Modification in Transtibial Amputees
NCT03164356 ·Status: COMPLETED ·Phase: NA
-
Influence of Prosthetic Foot Stiffness on Transtibial Osseointegrated Bone-Anchored Limb Outcomes
NCT07263945 ·Status: RECRUITING ·Phase: PHASE1
-
A Test-Drive Strategy for the Prescription of Prosthetic Feet for People With Leg Amputations
NCT03651830 ·Status: COMPLETED ·Phase: NA
-
Pivot-Flex Foot: Optimal Coupling Ratio Between Transverse and Sagittal-plane Motions Using a Torsionally Adaptive Prosthesis for Individuals With Lower Limb Amputation
NCT03532100 ·Status: COMPLETED ·Phase: NA
-
Weight-bearing Exercise for Trans-tibial Amputees
NCT05095805 ·Status: COMPLETED ·Phase: NA
-
Deploying Digital Prosthetic Interface Technology and Exercise in Dysvascular Amputees
NCT05656924 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE2
-
Insole Sensor to Determine Optimal Limb Loading
NCT02170493 ·Status: COMPLETED
-
Understanding How Powered Componentry Impacts K2-Level Transfemoral Amputee Gait
NCT06433648 ·Status: RECRUITING ·Phase: NA
-
Women's-Specific Footwear With Prosthetic Feet
NCT03673371 ·Status: COMPLETED
-
Kinematic and Kinetic Effects of Orthotic Devices for Subjects With Stage II Posterior Tibial Tendon Dysfunction
NCT01749657 ·Status: UNKNOWN ·Phase: NA
-
The Safety of Reusing Walking Boot Components for Patients Recovering From Acute Foot and Ankle Injuries
NCT07287969 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Efficacy of Foot Orthotics in Veterans With Chronic Lower Back Pain
NCT01865539 ·Status: TERMINATED ·Phase: NA
-
Powered Prosthesis for Use With TF Osseointegration Recipients
NCT06160882 ·Status: RECRUITING ·Phase: NA
-
Criteria for Advanced Prosthetic Foot Prescription
NCT03505983 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
INBONE Total Ankle Arthroplasty(TAA)Using Calcaneal Stem Fixation
NCT01366989 ·Status: TERMINATED
-
Microprocessor Knees in Early Rehabilitation
NCT03433300 ·Status: COMPLETED ·Phase: NA
-
Metabolic Cost Savings for Transtibial Amputees Wearing the Controlled Energy Storage and Return (CESR) Foot
NCT00494143 ·Status: COMPLETED ·Phase: PHASE3
-
Somatosensation Device Trial
NCT06168396 ·Status: COMPLETED ·Phase: NA
-
Clinical Trial of Footwear in Patients With Diabetes
NCT00032864 ·Status: COMPLETED
-
Influence Of A Slope Adaptive Foot On Participation Of Veterans With Lower-Limb Amputations
NCT07266077 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Low Cost Socket for Lower Limb Amputees
NCT04725461 ·Status: COMPLETED ·Phase: NA
-
Biomechanical Evaluation of a Novel, Compliant Low Profile Prosthetic Foot
NCT06468059 ·Status: COMPLETED ·Phase: NA
-
Use of an Integrated Orthotic and Rehabilitation Initiative for Treatment of Lower Extremity Musculoskeletal Disorders
NCT05780502 ·Status: RECRUITING
-
Treatment Outcomes for Ankle Arthritis
NCT00391365 ·Status: COMPLETED
-
Adherence and Perspiration While Wearing Lower Limb Prostheses
NCT03900845 ·Status: COMPLETED ·Phase: NA