Post-Extrasystolic Potentiation as a Predictor of Ventricular Arrhythmias

NCT03631303 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 30

Last updated 2018-11-20

No results posted yet for this study

Summary

Background: Patients at increased risk for sudden cardiac death (SCD) may receive an implantable cardioverter defibrillator (ICD). The primary criterion for a primary prevention ICD implantation is a left ventricular ejection fraction (LVEF) below 35%, but refinement of ICD criteria is important since only a small proportion of ICD patients receives appropriate device therapy (ATP or a shock) during follow-up. Post-extrasystolic potentiation (PESP) may be a new risk marker for SCD. PESP is defined as a temporary increase in contractility that follows an extrasystolic beat (ESB) and is associated with myocardial calcium handling. In heart failure, changes in calcium homeostasis may lead to afterdepolarisations and thus predispose for SCD. PESP can be measured indirectly and non-invasively as post-extrasystolic blood pressure potentiation (PESP-BP). Abnormal PESP-BP was previously found to be an independent predictor of increased mortality in post-myocardial infarction patients with a reduced LVEF. However, it is unknown if this increased mortality in heart failure patients with abnormal PESP-BP is caused by an increased risk of SCD.

Hypothesis: The investigators hypothesize that PESP-BP might be a new predictor of the occurrence of SCD, and can be used to enhance patient selection for primary prevention ICD therapy.

Design: During scheduled device replacement ESB with various extrasystolic and post-extrasystolic coupling intervals will be evoked by electrical stimulation via the right atrial and ventricular device leads of the patient. Throughout the stimulation study blood pressure will be measured non-invasively a continuous electrocardiogram will be recorded. Either before or after the procedure, patients will undergo a 30-minutes assessment of spontaneous ESB, again with blood pressure and ECG recordings.

Study population: 30 patients who are scheduled for device replacement or reposition, are eligible for this study; (1) 10 ICD patients who previously received appropriate device therapy (ADT); (2) 10 ICD patients who are free from ADT and (3) 10 dual-chamber pacemaker patients (control group).

Outcomes: (1) Evoked PESP-BP (i.e. blood pressure differences between baseline, ESB and post-ESB); (2) Spontaneous PESP-BP (i.e. blood pressure differences between baseline, ESB and post-ESB); (3) Timing parameters (in ms): the basic cycle length interval; Extra-systolic interval (ESI); Post-extrasystolic interval (PESI).

Conditions

  • Post-extrasystolic Potentiation (PESP)
  • Ventricular Tachycardia

Interventions

DEVICE

Cardiac stimulation through the device leads

During scheduled device replacement extra-systolic beats with various extrasystolic and post-extrasystolic coupling intervals will be evoked by electrical stimulation via the right atrial and ventricular device leads of the patient. Throughout the stimulation study blood pressure will be measured non-invasively using a finger arterial blood pressure photoplethysmographic device and a continuous electrocardiogram will be recorded.

Sponsors & Collaborators

  • Amsterdam UMC, location VUmc

    lead OTHER

Principal Investigators

  • Cornelis P. Allaart, MD, PhD · Amsterdam UMC, location VUmc

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2018-09-01
Primary Completion
2019-09-01
Completion
2020-03-01
FDA Device
Yes

Countries

  • Netherlands

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.