CrYobiopsy With Radial UltraSound Guidance

NCT03506295 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10

Last updated 2019-11-12

Study results available
· View outcomes & findings →

Summary

Transbronchial cryobiopsy carries a higher chance of establishing pathological diagnosis in diffuse parenchymal lung disease (DPLD) than traditional transbronchial forceps guided biopsy. It is a novel technique capable of obtaining large, high-quality samples of lung tissue in a minimally invasive manner. This procedure may decrease the need for surgical lung biopsy in 75% of cases. However, there is an increased risk of pneumothorax and airway bleeding compared to traditional transbronchial forceps guided biopsy.

Several strategies are used by practitioners of this technique to mitigate the risks of significant bleeding and pneumothorax. These include prophylactic placement of an endobronchial blocker, the use of fluoroscopy guidance, instillation of cold saline to promote vasoconstriction, and establishment of a secure airway with endotracheal tube placement or rigid bronchoscopy

. Vanderbilt University Medical Center is one of the most active centers in terms of cryobiopsies performed as part of the diagnostic workup of DPLD. Currently all transbronchial cryobiopsies here are performed under fluoroscopic guidance, with endotracheal tube intubation and endobronchial blocker placement. Despite these precautions, post biopsy bleeding complications occur and can substantially lengthen the duration of the procedure and occasionally expose patients to procedural complications.

Radial ultrasound has been well utilized to define anatomy of peripheral lung and localization of peripheral pulmonary nodules. We postulate that using radial ultrasound to identify peribronchial lung parenchyma with low vascularity will mitigate the risk of hemorrhage during peripheral lung cryobiopsy in patients with DPLD and hence improve patient safety.

Conditions

  • Pulmonary Disease

Interventions

DEVICE

Radial Endobronchial Ultrasound Probe

The radial EBUS procedure is performed by inserting a miniature ultrasound probe (radial EBUS probe) through the working channel of a flexible bronchoscope or catheter (guide sheath). Real-time imaging of the surrounding tissue enables the clinician to determine the lesion's exact location and size.

DEVICE

Flouroscopy

Real-time fluoroscopy will be used in all cases to guide the radial probe ultrasound and/or cryobiopsy probe placement.

Sponsors & Collaborators

  • Vanderbilt University Medical Center

    lead OTHER

Principal Investigators

  • Fabien Maldonado, MD · Vanderbilt University Medical Center

Study Design

Allocation
RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
DOUBLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2018-04-06
Primary Completion
2018-10-03
Completion
2018-10-03
FDA Device
Yes

Countries

  • United States

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03506295 on ClinicalTrials.gov