The Influence of the Crown-implant Ratio on the Crestal Bone Level and Implant Secondary Stability
NCT03471000 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2020-01-14
Summary
The aim of the study was to determine whether implant length and the crown-to-implant (C/I) ratio influence implant stability and the loss of the surrounding marginal bone, and whether short implants can be used instead of sinus augmentation procedures.
Conditions
- Partial Edentulism
- Tooth Loss
Interventions
- OTHER
-
Short implants Treatment
Short implants are placed in the alveolar bone and a clinical Ostell and Periotest evaluation of the implants after a period of time is done. Analysis of periapical radiographs and CBCT images after a period of time. Bone around the implant was measured, marginal bone level loss is determined.
- OTHER
-
Regular implants Treatment
Sinus lift procedure is done and regular implants are placed in the alveolar bone and a clinical Ostell and Periotest evaluation of the implants after a period of time is done. Analysis of periapical radiographs and CBCT images after a period of time. Bone around the implant was measured, marginal bone level loss is determined.
Sponsors & Collaborators
-
Dentsply Sirona Implants and Consumables
collaborator INDUSTRY -
Wrocław Medical University
collaborator UNKNOWN -
Jakub Hadzik
lead OTHER
Principal Investigators
-
Marzena Dominiak, Prof · Medical University Wrocław
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2012-01-01
- Primary Completion
- 2016-01-01
- Completion
- 2016-01-01
More Related Trials
-
Influence of the Implant Connection on Facial Tissues Maturation
NCT04160689 ·Status: COMPLETED ·Phase: PHASE4
-
Short Dental Implants (5 mm) Versus Long Dental Implants (10 mm)
NCT04144322 ·Status: COMPLETED ·Phase: NA
-
Comparative Aesthetic Analysis Between Titanium and Ceramic Implants
NCT04707677 ·Status: COMPLETED ·Phase: NA
-
Microanalysis of Changes in 3D Geometry of Orthodontic Mini-implants
NCT06743360 ·Status: ACTIVE_NOT_RECRUITING
-
Implant-fixed Restorations With ANKYLOS 6.6 mm Implants in the Edentulous Maxilla - A 5-year Follow-up Study
NCT02656823 ·Status: COMPLETED ·Phase: NA
-
Natural Dentition, Prosthesis and Antagonist Wear 3D Analysis
NCT05637619 ·Status: RECRUITING
-
Prosthetic Outcomes and Clinical Performance of Implant Supported Zirconia Crowns
NCT06417632 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of Synthetic Bone Substitute and a Bovine-derived Xenograft in Horizontal Bone Augmentation
NCT00901017 ·Status: COMPLETED ·Phase: NA
-
Influence of Soft Tissue Thickness on the Bone Level Around Implants
NCT04243460 ·Status: COMPLETED ·Phase: NA
-
Patient Perception and Oral Function of Implant Restorations
NCT06463405 ·Status: RECRUITING ·Phase: NA
-
CF41102 5-year Clinical Evaluation of Conelog® Implant With 7 mm Length
NCT03558347 ·Status: UNKNOWN ·Phase: NA
-
Short Implants Supporting Single Crowns in the Posterior Region
NCT05081050 ·Status: COMPLETED
-
Posterior Implant-Supported Modified Monolithic Zirconia and Metal-Ceramic Single Crowns: 5 Years Study
NCT04355325 ·Status: UNKNOWN ·Phase: NA
-
Association of Implant Position and Crown Contour With Tissue Health
NCT05644470 ·Status: RECRUITING
-
Immediate Implant Placement in Fresh Extraction Sockets and Delayed Implants in Healed Sockets.
NCT04346706 ·Status: COMPLETED ·Phase: NA
-
Effect of Placing the Implant Crown on the Implant on the Same Day as the Implant vs. 4 Weeks Later.
NCT04319042 ·Status: RECRUITING ·Phase: NA
-
Comparative (Short vs. Standard) Length Implants in Early Stability Patterns.
NCT07162389 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison of Extra-short (4 mm) Implants Used as Distal Support of a Maxillary Full-arch Fixed Dental Prosthesis vs. 10 mm Implants Installed After Sinus Floor Elevation.
NCT03958448 ·Status: COMPLETED ·Phase: NA
-
Clinical Success of Short Dental Implants Alone and Standard Dental Implants Combined With Osteotome Sinus Floor Elevation in Posterior Maxillae
NCT02350075 ·Status: COMPLETED ·Phase: NA
-
Longitudinal Follow-up After C1 Implant Stabilization Values
NCT01746160 ·Status: COMPLETED ·Phase: NA
-
Digital Technique to Analyze the Wear of Implants and Natural Tooth as Antagonist.
NCT05842655 ·Status: COMPLETED ·Phase: NA
-
Outcome of Implant-supported Overdentures
NCT03777748 ·Status: UNKNOWN ·Phase: NA
-
A 36-month Analysis of the Clinical Performance of Individualized CAD/CAM-produced Dental Implants: a Cohort Study
NCT06576284 ·Status: RECRUITING
-
Evaluation Of Marginal Bone Height Changes And Biting Force In Screw Retained Implant Prostheses Using Reinforced Resin Vs Monolithic Zirconium
NCT07007572 ·Status: RECRUITING ·Phase: PHASE2
-
Evaluation of Clinical Wear and Surface Roughness of Partial Restorations Produced by Additive and Subtractive Manufacturing Methods: A Split-Mouth Randomized Controlled Clinical Trial
NCT07057401 ·Status: NOT_YET_RECRUITING ·Phase: NA