Correlation Between In-vivo Anatomy of Corneal Dystrophies as Assessed by High- Resolution Optical Coherence Tomography (OCT) Measurement and Histological Examination

NCT03461991 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 2

Last updated 2025-05-23

No results posted yet for this study

Summary

Corneal dystrophies are usually classified histopathologically according to the layer of the cornea that is affected. The International Committee for the Classification of Corneal Dystrophies (IC3D) takes this anatomical classification as referral with summarizing clinical, genetic, and pathological data.

Most of this classification relies on slit lamp findings or histologic specimen, since in-vivo imaging of corneal microstructures has only become available in the recent years. With confocal microscopy it is possible to image corneal microstructures at a high resolution, but this technique is limited by its reduced repeatability and the fact that only a small area can be imaged. By the use of optical coherence tomography (OCT) systems it is possible to overcome these limitations. Commercially available systems, however, only have an axial resolution of about 18 µm which is not sufficient for imaging of all corneal layers.

Recently, a high-resolution optical coherence tomography (OCT) system was developed at the Center for Medical Physics and Biomedical Engineering that enables a resolution of about 1 µm. With this resolution, all corneal structures and several pathologies can be visualized.

In the present study the investigators want to use this OCT system to image corneal dystrophies in patients scheduled for corneal transplantation.

Conditions

  • Corneal Dystrophy

Interventions

DEVICE

Ultrahigh resolution Spectral Domain OCT

A spectrometer based ultrahigh resolution Spectral Domain OCT (SDOCT) system operating at 800 nm for the anterior chamber will be employed in the present study. The spectrum of the Ti:Sapphire laser light source is centered at 800 nm. With a full width at half maximum bandwidth of 170 nm, the axial resolution is 1.3 μm in the cornea. The transverse resolution of the employed OCT system is 21 μm at the front surface of the cornea. For measurement, patients will place their head in a modified slit lamp head rest. During the measurement period, patients will be asked to look straight forward onto an internal fixation target and to avoid blinking. Different scattering patterns, e.g. raster, circular and spiral scans will be employed.

Sponsors & Collaborators

  • Medical University of Vienna

    lead OTHER

Study Design

Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2018-08-21
Primary Completion
2022-08-29
Completion
2022-08-29

Countries

  • Austria

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03461991 on ClinicalTrials.gov