Impella CP With VA ECMO for Cardiogenic Shock
NCT03431467 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 17
Last updated 2025-11-19
Summary
Veno-arterial extra-corporeal membrane oxygenation (VA-ECMO) is indicated as a haemodynamic rescue strategy in decompensated acute or chronic heart failure presenting as cardiogenic shock. It has been used across aeitologies including post-myocardial infarction, dilated cardiomyopathy, acute myocarditis and in post-cardiotomy shock. VA ECMO has a number of effects on the circulation including improved end-organ perfusion and possibly improved coronary perfusion, and is a bridge to further therapies including permanent advanced mechanical circulatory support, cardiac transplantation and to cardiac recovery.
Left ventricular assist devices (LVADs) provide long-term mechanical circulatory support and also profoundly mechanically unload the left ventricle. Multiple clinical studies have documented cardiac recovery using LVAD therapy, with a rate between 10-60% in selected populations. A large body of basic science has documented the pivotal role of mechanical load in determining ventricular contractile performance across species. Therefore both clinical data and basic laboratory studies support the notion that profound ventricular unloading may result in improved cardiac performance through a variety of mechanisms ranging from triggered de novo cardiomyocyte proliferation, subcellular calcium handling reverse remodeling, changes to the extracellular matrix of the heart, reverse remodeling of the neurohormal milleu, amongst many others.
One of the major deficiencies of peripheral VA-ECMO is its lack of left ventricular unloading, with associated pulmonary congestion, which can derail clinical improvement and hamper cardiac recovery. Indeed, percutaneous VA-ECMO increases LV afterload due to the retrograde blood flow, and because of the lack of venting, there may be progressive LV distension. These conditions can result in a congested, pressure-overloaded ventricle, even in the absence of echocardiographic ventricular distension. This may be ameliorated with the addition of ventricular mechanical unloading using percutaneous therapies including the percutaneous left ventricular device, Impella CP.
On the platform of VA-ECMO, the addition of an Impella device to reduce ventricular loading results in improved survival and recovery of ventricular performance in the setting of cardiogenic shock. In a number of small studies, the use of additional means to unload the ventricle, principally Impella, results in cardiac recovery and less ventricular distension. In chronic heart failure, direct ventricular unloading is critical to cardiac recovery.
The objective of this randomized study is to determine whether the addition of early direct ventricular unloading using Impella CP leads to higher rates of cardiac recovery, defined as survival free from mechanical circulatory support, heart transplantation or inotropic support at thirty days. This study will also examine the clinical, biochemical, echocardiographic and radiologic effects of VA ECMO with and without the addition of Impella CP to directly vent the left ventricle to address adjunct important questions such as the effects on pulmonary congestion.
Conditions
- Cardiogenic Shock
Interventions
- DEVICE
-
Impella-CP LV Vent
Patients randomised to the experimental arm will have an Impella-CP implanted in addition to VA-ECMO within a maximum of 10 hours of institution of VA-ECMO
Sponsors & Collaborators
- lead OTHER
Principal Investigators
-
Christian Bermudez, MD · University of Pennsylvania
-
Michael Ibrahim, MD PhD · University of Pennsylvania
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2018-03-19
- Primary Completion
- 2023-09-01
- Completion
- 2023-09-01
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Early Feasibility Study of the AccuCinch® Ventricular Restoration System in Patients With Prior Mitral Valve Intervention (PMVI) and Recurrent Mitral Regurgitation
NCT03560167 ·Status: COMPLETED ·Phase: NA
-
Transcatheter Mitral Valve Replacement With the Medtronic Intrepid™ TMVR System in Patients With Severe Symptomatic Mitral Regurgitation.
NCT03242642 ·Status: RECRUITING ·Phase: NA
-
Enhanced External Counterpulsation
NCT01355315 ·Status: COMPLETED
-
Permanent Pacing for Drug-refractory Symptomatic Patients With Obstructive Hypertrophic Cardiomyopathy.
NCT05771987 ·Status: UNKNOWN ·Phase: NA
-
The AMPLATZER™ Post-infarct Muscular VSD Occluder Humanitarian Device Exemption (H070005) Post Approval Study
NCT03165526 ·Status: COMPLETED
-
Efficacy and Safety of the CorVad Percutaneous Ventricular Assist System in Cardiogenic Shock
NCT06646224 ·Status: RECRUITING ·Phase: NA
-
Magenta Elevate™ Clinical Feasibility Study in Cardiogenic Shock
NCT07293923 ·Status: RECRUITING ·Phase: NA
-
Multicenter Trial of ECMO in Children With Severe Cardiac Failure Using the Cardiohelp System
NCT06080074 ·Status: RECRUITING ·Phase: PHASE2
-
Evaluation of Myocardial Improvement in Patients Supported by Ventricular Assist Device Under Optimal Pharmacological Therapy
NCT00402376 ·Status: TERMINATED ·Phase: PHASE4
-
Standardized Goal-Directed vs. Self-Directed Valsalva Maneuver for the Assessment of Patent Foramen Ovale
NCT06670781 ·Status: RECRUITING ·Phase: NA
-
Stimulation of the Diaphragm in Patients With Severe Heart Failure Following Heart Surgery
NCT00769678 ·Status: COMPLETED ·Phase: NA
-
Beta-blocker Administration for Cardiomyocyte Division
NCT04713657 ·Status: RECRUITING ·Phase: PHASE1
-
The V-Wave Shunt: FIM Safety and Feasibility Study
NCT01965015 ·Status: COMPLETED ·Phase: NA
-
Closure of Perimembranous Ventricular Septal Defects With The AMPLATZER® Membranous VSD OCCLUDER
NCT00578708 ·Status: COMPLETED ·Phase: PHASE1
-
FLOTRAC/VIGILEO in Acute Circulatory Failure
NCT01090791 ·Status: TERMINATED
-
CentriMag Ventricular Assist System in Treating Failure-to-Wean From Cardiopulmonary Bypass for Pediatric Patients
NCT01171950 ·Status: WITHDRAWN ·Phase: NA
-
Pediatric REPlAcement of the PulmonaRy ValvE in Tetralogy of Fallot -
NCT03634072 ·Status: TERMINATED ·Phase: NA
-
Clinical Evaluation of the TRVD™ System in ADHF
NCT03621436 ·Status: TERMINATED ·Phase: NA
-
Phase II Clinical Trial of Percutaneous Ventricular Restoration Using Heartech® Device Preventing Heart Failure Post Myocardial Infarction (The Partical Study)
NCT04039256 ·Status: UNKNOWN ·Phase: NA
-
PC-Trial: Patent Foramen Ovale and Cryptogenic Embolism
NCT00166257 ·Status: UNKNOWN ·Phase: PHASE4
-
Identifying and Facilitating Ventricular Recovery on Mechanical Support
NCT00687856 ·Status: COMPLETED
-
A First in Human Study for the Versa Device for Tricuspid Regurgitation
NCT06368401 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
PVP-Guided Decongestive Therapy in HF
NCT05217342 ·Status: UNKNOWN ·Phase: PHASE4
-
Safety Study of the Ventricular Partitioning Device (VPD) Implant System in Heart Failure Patients
NCT00573560 ·Status: COMPLETED ·Phase: PHASE1
-
Vsling™ III: Clinical Evaluation of the Vsling™ Device for Ventricular Repair in Patients with Heart Failure
NCT06002386 ·Status: NOT_YET_RECRUITING ·Phase: NA