Contrast-enhanced 3D T1-weighted Gradient-echo Versus Spin-echo 3 Tesla MR Sequences in the Detection of Active Multiple Sclerosis Lesions

NCT03268239 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 180

Last updated 2026-01-06

No results posted yet for this study

Summary

Gadolinium-enhanced magnetic resonance imaging (MRI) is currently the imaging gold standard to detect active inflammatory lesions in multiple sclerosis (MS) patients. The sensitivity of enhanced MRI to detect active lesions may vary according to the acquisition strategy used (e.g., delay between injection and image acquisition, contrast dose, field strength, and frequency of MRI sampling). Selection of the most appropriate T1-weighted sequence after contrast injection may also influence sensitivity. Several clinical studies performed at 1.5 Tesla have shown that conventional 2D spin-echo (SE) sequences perform better than gradient recalled-echo (GRE) sequences for depicting active MS lesions after gadolinium injection. As relates to MS, 3.0 Tesla systems offer some advantages over lower field strengths, such as higher detection rates for T2 and gadolinium-enhancing brain lesions, an important capability for diagnosing and monitoring MS patients. Recent studies have shown that at 3 Tesla, 3D GRE or 3D fast SE sequences provide higher detection rates for gadolinium-enhancing MS lesions, especially smaller ones, than standard 2D SE, and better suppress artefacts related to vascular pulsation. However, the comparison of the performance of 3D GRE versus 3D SE sequences has not been investigated yet.

Objectives To compare the sensitivity of enhancing multiple sclerosis (MS) lesions in gadolinium-enhanced 3D T1-weighted gradient-echo (GRE) and turbo-spin-echo (TSE) sequences.

Conditions

Interventions

DEVICE

Additional MRI sequences

Due to the participation in the study, the following sequences are added to the imaging protocol: * 3D T1 GRE after injection (Gradient-Recalled Echo) * 3D T1 TSE before injection (Turbo Spin Echo) * 3D fGATIR PSIR after injection (fast Gray Matter Acquisition T1 Inversion Recovery Phase-Sensitive Inversion Recovery) Sequences will be performed in a random order to avoid the bias induced by different time intervals between injection and acquisition.

Sponsors & Collaborators

  • Fondation Ophtalmologique Adolphe de Rothschild

    lead NETWORK

Study Design

Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2017-08-02
Primary Completion
2021-04-26
Completion
2021-04-26

Countries

  • France

Study Locations

More Related Trials

Entities

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03268239 on ClinicalTrials.gov