Hysteroscopic Surgery in Treatment of Intrauterine Abnormalities
NCT03265301 · Status: WITHDRAWN · Phase: NA · Type: INTERVENTIONAL
Last updated 2022-11-23
Summary
With the ongoing developments in the field of hysteroscopy during the past 15 years, hysteroscopic surgery is becoming safer and less invasive for the patient. Improved technology has enabled surgeons to perform many operative procedures in an ambulatory setting without significant patient discomfort and with potentially significant cost savings.
Office operative hysteroscopy (see and treat hysteroscopy) reduces the distinction between a diagnostic and an operative procedure, shifting the focus in health care away from inpatient diagnosis and treatment. The development of smaller-diameter hysteroscopes with continuous-flow system features and working channels, through which operative instruments can be introduced, has made it possible to treat some uterine and cervical diseases without the traditional need for cervical dilation or general anesthesia.
Use of specially designed hysteroscopic 5F mechanical instruments (e.g., scissors, biopsy cup, graspers, and corkscrews) has long been the only way to perform operative procedures in an ambulatory setting. However, although grasping forceps and scissors are excellent for treating adhesions, cervical polyps, and endometrial polyps smaller than or the same size as the larger endometrial polyps, or thick lesions (e.g., submucous fibroids) were difficult to treat successfully using such miniature, fragile instruments and without cervical dilation.
An important technologic advance occurred in 1997 with the introduction of a versatile bipolar electrosurgery system dedicated to hysteroscopy, the Gynecare VersaPoint (Ethicon, Inc., Somerville, NJ, USA), which represents a key point in the history of office operative hysteroscopy. With the use of 5F bipolar electrodes, the number of pathologic conditions treated using office operative hysteroscopy has increased tremendously, reducing the use of the resectoscope and the operating room to a smaller number of cases.
More recently, a new generation of electrical generators, allowing the use of bipolar energy on miniaturized electrodes, has been presented (Autocon 400 II; Karl Storz Endoscopy, Tuttlingen, Germany). The main advantage of these instruments is that they are reusable, thereby reducing the costs of office operative as those described for the Versapoint system.
The feasibility of ambulatory uterine surgery is not just dependent on recent technological advances in instrumentation such as miniaturization of equipment, but also the favorable anatomical characteristics of the uterus itself. The sensitive innervations of the uterus originate in the myometrium and extend to the outer serosal surface, whereas the endometrium and any fibrotic tissue within the cavity are less sensitive. Thus, procedures can be carried out without the use of analgesia or anesthesia.
However, a careful operative technique is of paramount importance, in particular, avoiding inadvertent deep penetration of the superficial myometrium when resecting lesions such as polyps, maintaining the lowest possible distension pressures, and expediting procedures through efficient surgical techniques.
Conditions
- Hysteroscopy
Interventions
- PROCEDURE
-
Hysteroscopy
Includes Video set up, mini-hysteroscope system, continuous inflow and outflow, rod lens or fiber optic lens Zero to 30 degree angle and mechanical instruments (Scissors,Graspers , Cup biopsy forceps and bipolar instruments)
- PROCEDURE
-
Office hysteroscopy
will be done in out patient clinic without anesthesia
- PROCEDURE
-
Conventional hysteroscopy
will be done in operative room under general anesthesia
Sponsors & Collaborators
-
Assiut University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 20 Years
- Max Age
- 45 Years
- Sex
- FEMALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-08-01
- Primary Completion
- 2019-01-01
- Completion
- 2019-08-01
Countries
- Egypt
Study Locations
More Related Trials
-
Pain in Different Office Hysteroscopy Diameter
NCT02939196 ·Status: UNKNOWN
-
Impact of Different Saline Pressures During Hysteroscopy on Visibility, Feasibility and Patients' Discomfort
NCT06620978 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Optimal Order of Concurrent Office Hysteroscopy and Endometrial Biopsy
NCT02472184 ·Status: COMPLETED ·Phase: NA
-
Early Outpatient Hysteroscopy Can Prevent Intrauterine Adhesion After Induced Abortion
NCT04166500 ·Status: COMPLETED ·Phase: NA
-
Hysteroscopic Metroplasty in Unexplained Infertile Women With Dysmorphic Uterus
NCT03579550 ·Status: UNKNOWN ·Phase: NA
-
Hysteroscopic Surgery; Retrospective Cross-sectional Study of Reproductive Outcome
NCT05560295 ·Status: COMPLETED
-
Hysteroscopic Assessment of Fallopian Tubal Patency
NCT02005263 ·Status: COMPLETED ·Phase: NA
-
Total Laparoscopic Hysterectomy vs Minilap Hysterectomy
NCT03251677 ·Status: COMPLETED ·Phase: NA
-
Misoprostol Versus Oxytocin Infusion On Reducing Blood Loss During Abdominal Myomectomy
NCT06325501 ·Status: RECRUITING ·Phase: PHASE3
-
Hysteroscopic Septoplasty by Different Modalities
NCT05802784 ·Status: COMPLETED ·Phase: NA
-
Study of Conventional Laparoscopic Hysterectomy Versus Robot-Assisted Laparoscopic Hysterectomy at a Teaching Institution
NCT01581905 ·Status: TERMINATED ·Phase: NA
-
Feasibility, Effectiveness and Safety of Outpatient Hysteroscopy
NCT04462835 ·Status: COMPLETED
-
Laparoscopic vs Vaginal Hysterectomy for Benign Gynaecological Disease
NCT03692832 ·Status: COMPLETED ·Phase: NA
-
Pain and Hysteroscopy
NCT05316506 ·Status: COMPLETED ·Phase: NA
-
Uterine Cavity Assessment and Endometrial Hormonal Receptors in Women With Peri and Post Menopausal Bleeding
NCT02385747 ·Status: COMPLETED ·Phase: NA
-
Prevention of Intrauterine Adhesions After Hysteroscopic Metroplasty With Autocross-linked Hyaluronic Acid Gel
NCT02404454 ·Status: UNKNOWN ·Phase: NA
-
Uterine Artery Ligation at Origin in Total Laparscopic Hystrectomy
NCT04808583 ·Status: COMPLETED ·Phase: NA
-
Hysteroscopic Tissue Removal System Versus Bipolar Resectoscopy for Polypectomy: Long-term Results
NCT05337046 ·Status: COMPLETED
-
Surgical and Obstetric Outcomes in Patients With Uterine Malformations Undergoing Hysteroscopic Corrective Treatment
NCT06610864 ·Status: RECRUITING
-
Total Laparoscopic Hysterectomy Versus Total Abdominal Hysterectomy in Women With Endometrial Neoplasia
NCT03698604 ·Status: COMPLETED ·Phase: NA
-
Combined Hystroscopic and Laparoscopic Repair of CS Scar Disorder
NCT07183501 ·Status: RECRUITING ·Phase: NA
-
Tactile Electrosurgical Ablation in Cases of Dysfunctional Uterine Bleeding
NCT02248194 ·Status: COMPLETED ·Phase: PHASE2
-
Investigation of the Effect of Distention Medium Temperature on Image Quality, Hyponatremia Risk, and Post-operative Pain in Operative Hysteroscopy
NCT05973045 ·Status: RECRUITING ·Phase: NA
-
Randomized Clinical Trial Comparing Conventional Laparoscopic and Robot-Assisted Laparoscopic Hysterectomy
NCT02118974 ·Status: COMPLETED ·Phase: NA
-
Laparoscopic Assisted Doderlin Vaginal Hysterectomy
NCT03144414 ·Status: COMPLETED ·Phase: NA