Esophageal Deviation in Atrial Fibrillation Ablation
NCT03261973 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 47
Last updated 2021-06-30
Summary
Catheter ablation with pulmonary vein (PV) isolation is a commonly performed strategy employed for the treatment of atrial fibrillation (AF). However, ablation in the posterior wall of the left atrium can cause thermal injury to the esophagus. Thermal injury is very common and occurs in up to 40% of AF ablations per some studies. When significant thermal injury to the esophagus occurs, two significant complications can arise: 1) the formation of an atrio-esophageal fistula, and 2) gastrointestinal dysmotility. While the occurrence of fistula is rare, it is a very important complication since it is often fatal. Currently luminal esophageal temperature monitoring is the most commonly employed modality to prevent such injury. However, there are limitations to its use, and atrio-esophageal fistulas continue to be a major problem in AF ablation even when using esophageal temperature monitoring. Esophageal deviation using either a Transesophageal echocardiogram (TEE) or Esophagogastroduodenoscopy (EGD) probe has been described in the literature, but the effectiveness and practicality of these techniques are suboptimal, and have therefore precluded their use in routine clinical practice. Recently, esophageal deviation using off-the-shelf equipment (a soft thoracic tube and endotracheal stylet) was tested in the randomized double-blind multicenter study "Deviating the Esophagus in Atrial Fibrillation Ablation (DEVIATE-AF)". In that study the standard practice (i.e., use of luminal esophageal temperature monitoring) was compared to esophageal deviation using off-the-shelf equipment. The results were very encouraging showing that esophageal deviation allowed for significant reductions in esophageal temperature and proportion of premature ablation terminations. Importantly, esophageal deviation allowed the isolation all PVs in the treatment group, which was not the case in the control group. One major limitation in the DEVIATE-AF trial was that off-the-shelf equipment tool was challenging to use. The aim of the Esophageal Deviation in Atrial Fibrillation Ablation study is to test the feasibility and safety of moving the esophagus using a specialized esophageal deviation tool (DV8, Manual Surgical Sciences, Minneapolis, MN).
Conditions
Interventions
- DEVICE
-
DV8
DV8 esophageal deviation tool
Sponsors & Collaborators
-
Massachusetts General Hospital
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- PREVENTION
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2017-11-17
- Primary Completion
- 2020-06-15
- Completion
- 2020-06-15
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Prevalence and Predictors of Esophageal Thermal Lesions in High-power-Short-duration Ablation of Atrial Fibrillation
NCT05709756 ·Status: COMPLETED
-
Esophagus Deviation During Radiofrequency Ablation of Atrial Fibrillation - EASY AF STUDY
NCT04659213 ·Status: COMPLETED ·Phase: NA
-
Improving Oesophageal Protection During AF Ablation
NCT03819946 ·Status: UNKNOWN ·Phase: NA
-
Effect of Mechanical Ventilation on Radiofrequency Ablation in Atrial Fibrillation
NCT06791915 ·Status: RECRUITING
-
Esophageal Protection Study: A Multicenter Study
NCT04577859 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
OFDI Capsule Imaging in Patients With Atrial Fibrillation Undergone Radio Frequency (RF) Ablation
NCT02204566 ·Status: COMPLETED ·Phase: NA
-
A New Approach for Catheter Ablation of Atrial Fibrillation
NCT05989321 ·Status: COMPLETED
-
Esophageal Cooling for AF Ablation
NCT03691571 ·Status: COMPLETED ·Phase: NA
-
Esophageal Cooling in Radiofrequency Cardiac Ablation
NCT03481023 ·Status: COMPLETED ·Phase: NA
-
Safety and Efficacy of Catheter Ablation of Idiopathic Ventricular Arrhythmias Arising From Cardiac Outflow Tracts
NCT03258112 ·Status: WITHDRAWN ·Phase: NA
-
Efficacy of Different Ablation Strategies for Controlling Atrial Fibrillation
NCT00379301 ·Status: COMPLETED ·Phase: NA
-
Atrial Fibrillation Ablation on Gastric Motility "The AF Gut Study"
NCT01396356 ·Status: COMPLETED
-
Cryoballoon Pulmonary Venous Isolation in Patients Referred for Typical Atrial Flutter Ablation
NCT01521988 ·Status: COMPLETED ·Phase: NA
-
Effect of Catheter Ablation on Left Atrial Function in Persistent Atrial Fibrillation
NCT03443232 ·Status: COMPLETED ·Phase: NA
-
Effect of Left Atrial Appendage Velocity on Left Atrial Structure and Function After Radiofrequency Ablation Combined With Left Atrial Appendage Occlusion
NCT04693871 ·Status: COMPLETED
-
Safety Monitoring of Patients Having Pulmonary Vein Ablation
NCT00590668 ·Status: COMPLETED
-
Atrial Fibrillation Ablation Device Comparison Study
NCT00466973 ·Status: WITHDRAWN ·Phase: PHASE4
-
Cryoballoon vs. Irrigated Radiofrequency Catheter Ablation: Double Short vs. Standard Exposure Duration
NCT01913522 ·Status: COMPLETED ·Phase: NA
-
Catheter Ablation vs. Standard Conventional Treatment in Patients With LV Dysfunction and AF
NCT00643188 ·Status: COMPLETED ·Phase: PHASE4
-
Ablation of Low Voltage Regions in Persistent Atrial Fibrillation
NCT03811938 ·Status: UNKNOWN ·Phase: NA
-
Durability of Pulmonary Vein Isolation Following Cryoablation for Treatment of Paroxysmal Atrial Fibrillation
NCT01645917 ·Status: COMPLETED ·Phase: PHASE4
-
PrOgnosis Following Esophageal FisTula FormaTion in Pts Undergoing CathetER Ablation for AF Study
NCT05273645 ·Status: COMPLETED
-
Thoracoscopic Ablation Versus Catheter Ablation in Patients With Atrial Fibrillation
NCT04237389 ·Status: UNKNOWN ·Phase: NA
-
Radiofrequency and Cryoablation of the Posterior Wall of the Left Atrium
NCT06253000 ·Status: RECRUITING ·Phase: NA
-
Inflammatory and Endothelial Function Response, and Arrhythmia Recurrence Following Catheter Ablation for Atrial Fibrillation
NCT04269785 ·Status: WITHDRAWN ·Phase: NA