This is a non-randomized, open label, uncontrolled first in human safety study, testing the the material used in the artificial kidney device in subjects already on hemodialysis.
Six subjects already on hemodialysis, who meet the study inclusion and exclusion criteria, and who dialyze at one of the UCSF associated hemodialysis units will be recruited. Each subject will be tested during one non hemodialysis day, at the UCSF Moffitt-Long Hospital Acute Hemodialysis Unit (AHU).
The artificial kidney engineers have created a blood flow system that can be substituted for the dialysis filter in a standard hemodialysis machine. This is NOT a dialysis filter. It allows the subjects blood to come in contact with the material while the blood is being circulated as is regularly done during a hemodialysis session.
Conditions
- ESRD
Interventions
- DEVICE
-
HemoCartridge
Our goal is to apply MEMS (microelectromechanical systems) and nanotechnology to miniaturize the bioartificial kidney (BAK) into an implantable, self-monitoring, and self-regulating renal surrogate. The implantable BAK (iBAK) is a biocompatible cartridge containing stacks of hemofilter membranes (HemoCartridge) and renal tubule cell bioreactors (BioCartridge) combined to mimic nephron function. Here, we plan to test ONLY the material being used to construct the HemoCartridge, to be sure in humans when substituted for a standard hemodialysis filter, subjects don't develop any clinical problems or side effects during several hours of blood exposure to the material. The AK material will be engineered by the study team to allow the system to be substituted in place of a standard HD filter.
Sponsors & Collaborators
-
University of California, San Francisco
lead OTHER
Principal Investigators
-
Shuvo Roy, PhD · University of California, San Francisco
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2019-07-15
- Primary Completion
- 2020-02-15
- Completion
- 2020-06-30
- FDA Device
- Yes
More Related Trials
-
A Comparative Study of Two Kinds of Hemodialysis Filters
NCT05899283 ·Status: COMPLETED ·Phase: NA
-
Modeling of Regional Citrate Anticoagulation With a Dialysate Containing Calcium in Intermittent Hemodialysis (MARC)
NCT04530175 ·Status: COMPLETED
-
Phosphorus and Calcium Removal During Long Hemodialysis Treatment Sessions
NCT00633308 ·Status: WITHDRAWN ·Phase: PHASE2
-
High Flux Hemodialysis Thrice Versus Once
NCT00714662 ·Status: UNKNOWN ·Phase: PHASE3
-
Reduction of Microemboli of Air Using a New Developed Air Trap (EmbolessTM) During Haemodialysis
NCT06168539 ·Status: COMPLETED ·Phase: NA
-
Long-term, High Blood Flow Hemoadsorption Therapy in Patients Undergoing Maintenance Hemodialysis
NCT06574425 ·Status: ENROLLING_BY_INVITATION ·Phase: PHASE4
-
A Prospective Study of Airless Tubing in an Inpatient Acute Hemodialysis Unit in Hospitalized Patients
NCT02086682 ·Status: COMPLETED
-
High-Flow Needleless Valve and DualCap Disinfection Devices Associate With Catheter-related Bloodstream Infection
NCT02990923 ·Status: UNKNOWN ·Phase: PHASE4
-
Three-dimensional (3D) Printed Hemodialysis Vascular Model
NCT05096416 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Dialysis Performance of Different Dialyzer Membranes Using Different Coagulation Strategies
NCT03820401 ·Status: COMPLETED ·Phase: NA
-
Immediate Maintained Cannulation of a Newly Implanted Prosthetic Arteriovenous Access for Acute Hemodialysis
NCT00711750 ·Status: UNKNOWN
-
The Effect of On-line Hemodiafiltratrion on Nutritional Status and Body Composition
NCT03190629 ·Status: COMPLETED ·Phase: NA
-
Effects of Postdilution Online Hemodiafiltration With AcEtate-free Citrate dialySis Fluid on Inflammation Markers
NCT02863016 ·Status: COMPLETED
-
Toxins Removal and Inflammatory State modulAtion During Online Hemodiafiltration: Comparison of Two Different Dialyzers
NCT04554498 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of a Simplified Protocol for Regional Citrate Anticoagulation in Continuous Venovenous Hemodiafiltration
NCT00583765 ·Status: COMPLETED
-
Effect of a Pre Heparin Coated Dialysis Filter on Coagulation During Hemodialysis
NCT01388270 ·Status: COMPLETED ·Phase: PHASE4
-
Arrhythmia in Hemodialysis Patients
NCT04036695 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Expanded Hemodialysis Versus Online Hemodiafiltration
NCT03274518 ·Status: COMPLETED ·Phase: NA
-
Hemodialysis in the Elderly (70yrs & Older)
NCT03065972 ·Status: UNKNOWN ·Phase: NA
-
Catheter Dysfunction Rate in Patients Undergoing Kidney Replacement Therapy. Evaluation of the Safety and Efficacy of Anti-reflux Valves Without Heparin Lock Solution
NCT06259266 ·Status: WITHDRAWN ·Phase: NA
-
Does Incremental Initiation of Haemodialysis Preserve Native Kidney Function?
NCT03418181 ·Status: UNKNOWN ·Phase: NA
-
Wearable Cardioverter Defibrillator in Hemodialysis Patients (WED-HED) Study
NCT02481206 ·Status: TERMINATED ·Phase: NA
-
Effect of Hemodialysis Membranes on Platelet Count
NCT01356576 ·Status: COMPLETED
-
Reducing Hemodialysis Induced Recurrent Brain Injury to Improve Patients' Lives
NCT03342183 ·Status: COMPLETED ·Phase: NA
-
Multicenter Study on Dialysis Modalities for End-stage Chronic Renal Failure Patients With Heparin-induced Thrombocytopenia
NCT05586854 ·Status: UNKNOWN ·Phase: NA