Feasibility Assessment of the Blood Pressure Imager, a Continuous Blood Pressure Monitor
NCT03128944 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 100
Last updated 2020-03-27
Summary
The investigators are developing Blood Pressure Imager (BPI), which is a new technology that does not require cuffs or expensive equipment, and can be used by untrained individuals in underserved, low-resource environments at their own homes or regional care settings. Over the last one-year the investigators have developed the BPI prototype, which is ready for testing. BPI is a wrist device that includes a camera, color lights and soft membrane with a reflective coating. In this device feasibility study, the BPI will be placed over the radial artery at the wrist with the help of a wrist strap. The primary purpose of this feasibility study is to compare the BPI with a commercially available cuff-based blood pressure measuring devices.
Conditions
- Blood Pressure
- Hypertension
Sponsors & Collaborators
-
Tufts University
lead OTHER
Principal Investigators
-
Mohan Thanikachalam · Tufts University
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-05-01
- Primary Completion
- 2019-10-30
- Completion
- 2019-10-30
Countries
- United States
Study Locations
More Related Trials
-
A Novel Non-interfering Arterial Blood Pressure Monitoring Device
NCT01954446 ·Status: WITHDRAWN ·Phase: NA
-
Evaluation of a Novel Mobile Phone Application ( OptiBP) for Blood Pressure Monitoring
NCT04121624 ·Status: COMPLETED
-
Somnotouch-NIBP Compared to Standard Ambulatory 24 Hours Blood Pressure Measurement
NCT03054688 ·Status: COMPLETED ·Phase: NA
-
imPulse™ Tor System Self-Directed Cuffless Blood Pressure Monitoring
NCT05386654 ·Status: COMPLETED
-
Connected Health Blood Pressure Monitoring In Stroke and TIA Patients
NCT02450760 ·Status: COMPLETED ·Phase: NA
-
'Wristband Device for the Measurement of Intermittent Blood Pressure and Other Physiological Signals
NCT03409861 ·Status: UNKNOWN
-
App-based Remote Blood Pressure Monitoring
NCT05595629 ·Status: COMPLETED ·Phase: NA
-
Role of Wrist Based Blood Pressure Monitoring in Clinical Practice
NCT03862742 ·Status: WITHDRAWN
-
Contactless Radar Blood Pressure Validation
NCT06035107 ·Status: NOT_YET_RECRUITING
-
Validation of a Noninvasive Automated Blood Pressure Device
NCT03566888 ·Status: COMPLETED
-
Wrist-based Blood Pressure Monitoring Study
NCT03661112 ·Status: COMPLETED
-
Wearable Evaluation of Ambulatory Readings for Blood Pressure
NCT06610448 ·Status: RECRUITING ·Phase: NA
-
Accuracy of a Cuffless Photoplethysmography (PPG) Chest-Patch Monitor for 24-hour Ambulatory Blood Pressure Monitoring (ABPM)
NCT07240831 ·Status: RECRUITING ·Phase: NA
-
Non Invasive Continuous Blood Pressure Sensor
NCT05689294 ·Status: COMPLETED
-
Invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis
NCT03046264 ·Status: COMPLETED
-
Non-invasive Validation of Non-invasive Central Blood Pressure Measurements Using Oscillometric Pulse Wave Analysis
NCT03049709 ·Status: COMPLETED
-
Systolic Blood Pressure Measurement in Critically-ill Patients
NCT02366507 ·Status: COMPLETED
-
The Feasibility of a Web-based Application to Monitor Home Blood Pressure
NCT03116815 ·Status: COMPLETED ·Phase: NA
-
COOL-BP Study: Continuous Versus Occasional Blood Pressure Study
NCT05211648 ·Status: COMPLETED ·Phase: NA
-
Speckle Plethysmography Pulse Transit Time as a Marker of Blood Pressure Changes
NCT05554315 ·Status: COMPLETED
-
Comparison of Cuff-Less Wrist Wearable Blood Pressure Device to Cuff Based Blood Pressure Measuring Devices
NCT04835857 ·Status: RECRUITING
-
Where Should Automated Blood Pressures be Done in Primary Care Offices?
NCT01538004 ·Status: WITHDRAWN
-
Accuracy Study of a Non-Invasive Blood Pressure Cuff in Comparison to an Invasive Radial Arterial Blood Pressure
NCT01485120 ·Status: COMPLETED ·Phase: NA
-
SupportBP 2.0:Behavioral Science and Enrollment in Remote Monitoring for Hypertension Management
NCT04714398 ·Status: COMPLETED ·Phase: NA
-
Clinical Usefullness of the Cuffless SOMNOtouch NIBP Device for 24-hour Ambulatory Blood Pressure Measurement
NCT04278001 ·Status: COMPLETED ·Phase: NA