A Novel Diagnostic Method for Exotropia Using Video-oculography
NCT03119311 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 34
Last updated 2017-07-21
Summary
Thirty-four subjects with constant exotropia were included. Two independent ophthalmologists measured the angle of ocular deviation using alternate prism cover test (APCT). The video files and data with the changes in ocular deviation during the alternate cover test were obtained using video-oculography (VOG). To verify the accuracy of VOG, Investigator compared the value obtained using VOG and the angle of a rotating model eye, and subsequently made a new linear equation using these data. The calculated values obtained using VOG were compared with those obtained using APCT to determine the diagnostic accuracy of VOG.
Conditions
- Strabismus
- Exotropia
Interventions
- DIAGNOSTIC_TEST
-
Video-oculography
Diagnostic Method for Exotropia Using Video-oculography
- DIAGNOSTIC_TEST
-
APCT
alternative prism cover test
Sponsors & Collaborators
-
Inje University
lead OTHER
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 4 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2017-04-25
- Primary Completion
- 2017-06-30
- Completion
- 2017-07-10
Countries
- South Korea
Study Locations
More Related Trials
-
Effect of Lens Presentation on the Clinical Oculomotor Assessment at Near
NCT02679313 ·Status: WITHDRAWN ·Phase: NA
-
Evaluation of Exotropia After Patching the Eye or After Prism Adaptation
NCT05242510 ·Status: TERMINATED ·Phase: NA
-
Bifocal Spectacles vs. Single Vision Spectacles for Esotropia Greater at Near
NCT05527015 ·Status: WITHDRAWN ·Phase: PHASE3
-
Intermittent Exotropia in Egyptian Population
NCT06312865 ·Status: NOT_YET_RECRUITING
-
Study of Non-surgical Treatment Versus Observation in Asian Children With Intermittent Exotropia
NCT01267500 ·Status: TERMINATED ·Phase: NA
-
OCT-A and Amblyopia
NCT05223153 ·Status: COMPLETED
-
Part-time Patch Therapy for Treatment of Intermittent Exotropia
NCT03700632 ·Status: UNKNOWN ·Phase: NA
-
An Observational Cohort Study to Explore the Clinical Outcome of Congenital Strabismmus Based on Etiology and Timing of Surgery
NCT06614335 ·Status: ACTIVE_NOT_RECRUITING
-
Base-in Prism Spectacles for Intermittent Exotropia
NCT03998670 ·Status: COMPLETED ·Phase: NA
-
Lateral Rectus Muscle and Anterior Segment Optical Coherence Tomography (AS-OCT)
NCT02383381 ·Status: COMPLETED
-
Office Based Vergence and Accommodative Therapy and Intermittent Exotropia
NCT03321838 ·Status: UNKNOWN ·Phase: NA
-
Under-correction in Refractive Accommodative Esotropia
NCT01179711 ·Status: COMPLETED ·Phase: NA
-
Prism Adaptation in Symptomatic Esophoria - Effect of Shorter Time Intervals and Surgical Outcomes Based on Prism Adaptation
NCT06729710 ·Status: RECRUITING ·Phase: NA
-
A Pilot Clinical Trial of Overminus Spectacle Therapy for Intermittent Exotropia
NCT02223650 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Visual and Perceptual Training on Visual Function for Operative Congenital Ectopia Lentis Children
NCT07096622 ·Status: RECRUITING ·Phase: NA
-
Trial Comparing Near Versus Distance Activities While Patching for Amblyopia in Children 3 to <7 Years Old
NCT00315198 ·Status: COMPLETED ·Phase: PHASE3
-
Study of a Hand-held Device Plus Mobile App Versus Standard Eye Care Devices in Measuring Refractive Error of the Eye
NCT03929588 ·Status: COMPLETED ·Phase: NA
-
Excimer Laser Surgery for Anisometropic Amblyopia
NCT03342235 ·Status: WITHDRAWN ·Phase: NA
-
Dichoptic Video Treatment for Amblyopia
NCT03825107 ·Status: COMPLETED ·Phase: NA
-
Study in Pediatric Volunteers of a Handheld Device Versus a Standard Diagnostic Device in Ophthalmic Refraction
NCT04955379 ·Status: UNKNOWN ·Phase: NA
-
New Visual Acuity and Crowding Tests for Better Detection of Amblyopia
NCT03505606 ·Status: COMPLETED ·Phase: NA
-
Correction of Anisometropic Amblyopia in Children.
NCT05325021 ·Status: UNKNOWN
-
Trial of Overminus Spectacle Therapy for Intermittent Exotropia
NCT02807350 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Safety of Eyetronix Flicker Glasses to the Treatment of Anisometropic Amblyopia
NCT02970708 ·Status: UNKNOWN ·Phase: NA
-
Changes in Amblyopia Using Optical Coherence Tomography
NCT04092361 ·Status: UNKNOWN