NHLBI DIR LAMPOON Study: Intentional Laceration of the Anterior Mitral Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Implantation

NCT03015194 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 32

Last updated 2023-08-15

Study results available
· View outcomes & findings →

Summary

Background:

Transcatheter mitral valve replacement (TMVR) is recommended for some people with mitral valve heart problems. But the usual TMVR techniques might cause an obstruction for some people. A new technique is called LAMPOON. It may have less risk of obstruction. Participants in this study will be among the first in the world to have this technique done.

Objectives:

To test the safety and effectiveness of the LAMPOON technique in TMVR.

Eligibility:

Adults ages 21 and over who are recommended to have TMVR with LAMPOON

Design:

Participants will be screened with medical history and exam and by review of medical records.

Participants will have blood tests, an ECG, a heart CT scan, and an echocardiogram before the procedure.

Participants will have TMVR with LAMPOON. They will have anesthesia or moderate sedation for the procedure. Doctors will use a wire to split the diseased mitral valve and move it out of the way before inserting the artificial mitral valve.

Participants will recover in an inpatient recovery unit.

They will repeat the previous tests before leaving the hospital, 1 month later, 6 months later and 1 year later. They will have yearly follow-up phone calls for about 5 years.

In the event of a participant's death, researchers will ask for an autopsy and to analyze the heart. Permission for this is not required as part of the study.

Conditions

  • Mitral Valve Failure

Interventions

DEVICE

Edwards SAPIEN 3 transcatheter heart valve

Used to relieve aortic stenosis in patients with symptomatic heart disease In this study it is not used for aortic stenosis-----the device is used in the mitral valve position.

DEVICE

ASHI INTECC Astato XS 20

The Astato 0.014" guidewire is used for transcatheter electrosurgery in two steps in this procedure. First it is used for leaflet traversal during electrification. This procedure is similar to the use of the Astato XS20 and an amputated Asahi Confienza Pro 12 in the transcaval IDE investigation recently published. Second, the midshaft is focally denuded and electrified for the leaflet traversal step.

Sponsors & Collaborators

  • National Heart, Lung, and Blood Institute (NHLBI)

    lead NIH

Principal Investigators

  • Robert J Lederman, M.D. · National Heart, Lung, and Blood Institute (NHLBI)

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
21 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2017-06-20
Primary Completion
2018-07-26
Completion
2023-04-13
FDA Device
Yes

Countries

  • United States

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT03015194 on ClinicalTrials.gov