Melody Transcatheter Pulmonary Valve Study: Post Approval Study of the Investigational Device Exemption Cohort
NCT00740870 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 171
Last updated 2024-03-26
Summary
The primary objective is to confirm the long-term functionality of implantation of the Medtronic Melody TPV at 5 years is no worse than the historical control established through literature review. The secondary objectives are to evaluate long-term functionality at 10 years and to assess safety, procedural success, and clinical utility of transcatheter implantation of the Melody TPV.
Conditions
- Congenital Heart Defects
- Dysfunctional Right Ventricular Outflow Tract Conduits
Interventions
- DEVICE
-
Transcatheter Pulmonary Valve replacement
Transcatheter valve implantation into a RVOT conduit in patients with complex congenital heart defects where the conduit has become dysfunctional and where the patient needs invasive intervention.
Sponsors & Collaborators
-
Medtronic Cardiovascular
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 5 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2007-01-31
- Primary Completion
- 2015-05-31
- Completion
- 2020-08-21
Countries
- United States
Study Locations
More Related Trials
-
The Medtronic Harmony™ Transcatheter Pulmonary Valve Clinical Study
NCT02979587 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement
NCT01240902 ·Status: COMPLETED ·Phase: NA
-
NHLBI DIR LAMPOON Study: Intentional Laceration of the Anterior Mitral Leaflet to Prevent Left Ventricular Outflow Tract Obstruction During Transcatheter Mitral Valve Implantation
NCT03015194 ·Status: COMPLETED ·Phase: NA
-
CorMatrix Cor TRICUSPID ECM Valve Replacement - Pivotal Study
NCT05742906 ·Status: RECRUITING ·Phase: NA
-
Study to Assess Safety of the Pulmonary Valved Conduit (PV-001) in Subjects Undergoing Right Ventricular Outflow Tract Reconstruction
NCT02700100 ·Status: UNKNOWN ·Phase: NA
-
Follow Up on Freestyle Valves in Children
NCT00385112 ·Status: COMPLETED
-
Multicentre Study of Percutaneous Mitral Valve Repair MitraClip Device in Patients With Severe Secondary Mitral Regurgitation
NCT01920698 ·Status: COMPLETED ·Phase: NA
-
Early Feasibility Study of the Cardiovalve System for Tricuspid Regurgitation
NCT04100720 ·Status: WITHDRAWN ·Phase: NA
-
Transcatheter Tricuspid Valve Replacement With the Medtronic Intrepid™ Transcatheter Tricuspid Valve Replacement (TTVR) System in Severe Tricuspid Regurgitation
NCT07321899 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Medtronic Transcatheter Aortic Valve Replacement (TAVR) Low Risk Bicuspid Study
NCT03635424 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Cardiovalve Transfemoral Mitral Valve System
NCT03813524 ·Status: TERMINATED ·Phase: NA
-
Transcatheter Pulmonary Valve Implantation With SAPIEN 3 Valve
NCT05264181 ·Status: UNKNOWN
-
Cardiac Resynchronization Therapy in Congenital Heart Diseases With Systemic Right Ventricle
NCT04842851 ·Status: COMPLETED
-
Closure of Perimembranous Ventricular Septal Defects With The AMPLATZER® Membranous VSD OCCLUDER
NCT00578708 ·Status: COMPLETED ·Phase: PHASE1
-
Safety and Feasibility Study: Transcatheter Valve Repair in Severe Symptomatic Functional Tricuspid Regurgitation
NCT07140562 ·Status: RECRUITING ·Phase: NA
-
A Feasibility Study to Evaluate the Safety and Short-term Effectiveness of Transcatheter Pulmonary Valve (TPV)
NCT02555319 ·Status: COMPLETED ·Phase: NA
-
Pulmonary Valve Replacement in Large Right Ventricular Outflow Tract
NCT00259207 ·Status: COMPLETED ·Phase: PHASE3
-
Evaluation of the GORE PV1 Device in Patients With Pulmonary Valve Dysfunction
NCT03441971 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Clinical Evaluation of Percutaneous Implantation of the Medtronic CoreValve Aortic Valve Prosthesis (18Fr-Study)
NCT01051518 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Minimally Invasive VenTouch™ System in the Treatment of Functional Mitral Valve Regurgitation (FMR)
NCT02671799 ·Status: UNKNOWN ·Phase: NA
-
Transcatheter Mitral Valve Replacement System (TMVR) Pilot Study and The Early Feasibility Study of the TMVR Transseptal System
NCT02322840 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Transcatheter Mitral Valve Replacement With the Medtronic Intrepid™ TMVR System in Patients With Severe Symptomatic Mitral Regurgitation.
NCT03242642 ·Status: RECRUITING ·Phase: NA
-
Multicentre Study of MITRACLIP® Transcatheter Mitral Valve Repair in Patients With Severe Primary Mitral Regurgitation Eligible for High-risk Surgery
NCT03271762 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
MitraClip for the Treatment of Moderate Functional Mitral Regurgitation: EVOLVE-MR
NCT03705312 ·Status: UNKNOWN ·Phase: NA
-
Medtronic Evolut™ EXPAND TAVR I Feasibility Study
NCT04639258 ·Status: TERMINATED ·Phase: NA