Ankle - Brachial Index Measurement in Atrial Fibrillation
NCT02986282 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 115
Last updated 2017-07-18
Summary
Consecutive patients with atrial fibrillation will be admitted to the hospital for electrical cardioversion. Ankle brachial index will be measured three times with oscillometric method and three times with doppler method. Two study sessions will be performed: the first before and the second after electrical cardioversion. The first session will be ended before anesthesia. The second session will be started before a conscious patient will be transported from intensive care unit to general ward.
All the measurements will be taken in the intensive care unit at an ambient temperature of 21° C, after patients will give their written informed consent to participate in the study. All patients will be awake, fasting and in the supine position. ABI will be measured according to the guidelines issued by AHA. Systolic blood pressure will be measured using a Doppler device (Echo Sounder ES-101EX, Hadeco, Japan) and a validated and calibrated aneroid sphygmomanometer (Minimus II, Rister, Germany). Measurement of ABI using oscillometric method will be performed using WatchBP Office ABI system (Microlife WatchBP AG, Widnau, Switzerland). The appropriate cuff size will be used with the width of the cuff being at least 40% of the limb circumference. The arm with higher systolic blood pressure will be used to calculate the ABI. Higher systolic blood pressure measured on the posterior tibial or dorsalis pedis artery will be used to calculate the ABI. During both study sessions ABI measurements will be repeated 3 times with each method in the reverse order of the preceding measurement e.g., in the case of the initial counterclockwise sequence: right arm, right popliteal, right dorsalis pedis, left popliteal, left dorsalis pedis, left arm, right arm, the clockwise sequence will be used, starting and ending with the left arm. The same sequence of limb pressure measurements will be used used during the study.
A sample size calculation was based on the preliminary observations made by the study team. It was calculated that the study sample size of 79 subjects would be needed to detect a difference of 0.1 in the ABI measured in sinus rhythm and during atrial fibrillation, with a two-tailed α of 0.05 and a (1-β) of 0.90. The investigators initial estimate of sample size of 115 patients incorporated an assumption of dropout due to non-effective electrical cardioversion, patient decision to quit study or failure to obtain adequate ABI.
The measurements will be repeated three times with each method and for the each method the mean will be used for the calculations. Investigator - study nurse, trained at the vascular department, will perform all ABI measurements.
Conditions
- Atrial Fibrillation Fluttering
Interventions
- DEVICE
-
ABI measurement using both doppler and oscillometric method
Sponsors & Collaborators
-
Medical University of Warsaw
lead OTHER
Principal Investigators
-
Maciej Sinski, M.D., Ph.D. · Medical University of Warsaw
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-10-31
- Primary Completion
- 2015-12-31
- Completion
- 2015-12-31
More Related Trials
-
Echocardiographic Left Atrial Function Assessment and Atrial Fibrillation Post-Coronary Artery Bypass Surgery
NCT03487419 ·Status: UNKNOWN
-
Cardiac Index, SVR/SVRI During Weaning From ECC- Data Obtained From Femoral and Radial Artery Transducer
NCT06112561 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Predicting Severe Cardiac Arrhythmias in the Perioperative Period Using AI-ECG
NCT07348991 ·Status: NOT_YET_RECRUITING
-
Left Atrial Volume Index and Left Atrial Appendage Flow Velocities
NCT02500745 ·Status: UNKNOWN
-
Utility of Analyzing Atrial Signal Electrograms in Patients with Atrial Fibrillation Using Next-Generation Ensite X Software: a Prospective Study
NCT06632925 ·Status: ACTIVE_NOT_RECRUITING
-
An Intracavitary Electrocardiographic System for Real-time Positioning Peripherally Inserted Central Catheter Tip
NCT02409589 ·Status: COMPLETED ·Phase: NA
-
Electrical Cardioversion As a Predictor in Postoperative Preservation of Sinus Rhythm
NCT06654401 ·Status: RECRUITING ·Phase: NA
-
Continuous Ambulatory ECG Monitoring for Detection of Postoperative Atrial Fibrillation Following Thoracic Surgery
NCT04325269 ·Status: UNKNOWN
-
Non-invasive Blood Pressure and Cardiac Output Measurement by Using Applanation Tonometry
NCT02444104 ·Status: UNKNOWN
-
Electrocardiogram-based Artificial Intelligence-assisted Detection of Heart Disease
NCT05442203 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Multiparametric MRI Assessment of Atrial Heart Disease as a Predictor of Atrial Fibrillation After Myocardial Revascularization Surgery
NCT04657835 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Upper Extremity Function in Patients With Reduced Ejection Fraction Heart Failure and Cardiac Implantable Electronic Devices
NCT07253909 ·Status: ENROLLING_BY_INVITATION
-
Impact of Left Atrial Function on Postoperative Atrial Fibrillation
NCT00646997 ·Status: COMPLETED
-
Heart Rate Variability Changes During Cardiac Surgery And The Incidence Of Post-Operative Cardiac Arrhythmias
NCT01359683 ·Status: WITHDRAWN ·Phase: NA
-
Development of Novel Physiological CMR Methods in Health and Disease
NCT03854071 ·Status: RECRUITING ·Phase: NA
-
Assessment Of Right Ventricular Function In Patients Undergoing Coronary Artery Bypass Graft In Assiut University
NCT03275220 ·Status: UNKNOWN
-
Echocardiographic Findings and 30-days Outcomes for Intraventricular Conduction Delay in Patients Undergoing Elective Surgeries
NCT02718313 ·Status: COMPLETED
-
Impact of Intraventricular Electrical Activation in Resynchronization Therapy
NCT01270646 ·Status: COMPLETED ·Phase: PHASE2
-
Comparison of Dynamic Fluid Responsiveness by EIT and Transpulmonary Thermodilution in Postoperative of CABG Patients
NCT04362033 ·Status: UNKNOWN ·Phase: NA
-
Exercise Tolerance in Patients With Implanted Left Ventricular Assist Device
NCT05063006 ·Status: COMPLETED ·Phase: NA
-
Cloud-based ECG Monitoring and Healthcare Model Building on the Population With Coronary Artery Revascularization
NCT04485143 ·Status: UNKNOWN
-
Blood Velocity Variation in Right Renal and Superior Mesenteric Arteries During Cardio-pulmonary Bypass
NCT06009809 ·Status: RECRUITING
-
Comparison of Peri-procedural Complications of Intracardiac Echocardiography and Transesophageal Echocardiography in Patients With Atrial Fibrillation
NCT05466266 ·Status: UNKNOWN ·Phase: NA
-
Comparison of a New Semi-invasive Monitoring System With Transpulmonary Thermodilution in Cardiac Surgery Patients
NCT02312505 ·Status: COMPLETED ·Phase: NA
-
Interest of a Hybrid Connected Watch for Cardiac Rhythm Monitoring in Post-operative Cardiac Surgery
NCT05664308 ·Status: RECRUITING