Cough Peak Flow for Extubation Prediction

NCT02847221 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 92

Last updated 2016-07-28

No results posted yet for this study

Summary

Successful weaning from mechanical ventilation in ICU patients depends on patient ability to breathe spontaneously and on cough efficiency. Previous studies found that cough peak flow (CPF) at 60 L/min threshold predicted extubation failure. These studies measured CPF using a dedicated flow-meter that required patient disconnection from the ventilator, limiting the generalizability of this procedure. This study aimed to predict extubation outcome in a consecutive series of patients by measuring CPF from the ventilator flow-meter. CPF measurements were done by freezing ventilator screen and scrolling the cursor to the maximal value of CPF during expiration and Tidal Volume (TV) in preceding inspiration.

The objective was to assess the performance of CPF to predict early extubation outcome.

Conditions

  • Extubation in ICU Patients

Sponsors & Collaborators

  • Hospices Civils de Lyon

    lead OTHER

Principal Investigators

  • Florent GOBERT, MD · Hospices Civils de Lyon

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2014-11-30
Primary Completion
2015-10-31
Completion
2015-11-30

Countries

  • France

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT02847221 on ClinicalTrials.gov