The Clinical Application of MCCES in Examination of Human Colon
NCT02536144 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 80
Last updated 2015-08-31
Summary
This study is to determine the feasibility and safety of magnetic-controlled capsule endoscopy system in examination of human colon under the real time monitoring by colonoscopy in the clinical application.
Conditions
- Abdominal Pain
- Diarrhea
- Hematochezia
Interventions
- PROCEDURE
-
magnetic-controlled capsule endoscopy system
1. A magnetic-controlled capsule endoscopy(MCCE) included camera,magnet,batter and high polymer material shell. 2. The MCCE would be turned to sleeping mode capturing picture at a rate of 0.5 frame per second after being swallowed. 3. While reaching cecum, the MCCE would be turned to a working mode capturing picture at a rate of 2 frame per second. 4. The MCCE would be controlled by the Magnetic-manipulator out of body to finish the motion of e rotation, somersault, Bird's-eye view, worm's eye view from cecum to anus.
- PROCEDURE
-
Colonoscopy
1. Bowel preparation should be well done before the examination. 2. A tube with illumination and camera system would insert into colon from anus. 3. From the pictures captured by the camera ,the doctor would see the mucous of the colon.
Sponsors & Collaborators
-
Nanfang Hospital, Southern Medical University
lead OTHER
Principal Investigators
-
Bo Jiang, doctor · Nanfang Hospital, Southern Medical University
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2015-08-31
- Primary Completion
- 2015-09-30
- Completion
- 2015-09-30
Countries
- China
Study Locations
More Related Trials
-
Real-Time Identification System of Magnetically Controlled Capsule Endoscopy Using Artificial Intelligence
NCT04203264 ·Status: UNKNOWN
-
Efficacy of Magnetic Imaging Colonoscopy Applied to Beginner Endoscopists
NCT05746962 ·Status: UNKNOWN ·Phase: NA
-
Small Bowel Evaluation Using Novel Motorized Spiral Enteroscopy
NCT04959994 ·Status: UNKNOWN
-
Active Locomotion of Magnetically Controlled Capsule Endoscopy in the Small Bowel: A Feasibility Study
NCT07325344 ·Status: RECRUITING ·Phase: NA
-
Methodology and Clinical Value of RIT in Intestinal Obstructive Diseases Mediated by Colonic TET
NCT05253222 ·Status: UNKNOWN ·Phase: NA
-
Evaluation the Performance of Given Diagnostic System in Detection of Bleeding Events in the Small Bowel
NCT01441219 ·Status: TERMINATED ·Phase: PHASE2/PHASE3
-
Retrospective Review of Gastrointestinal System Endoscopy Procedures
NCT05012527 ·Status: COMPLETED
-
Evaluation of the PillCam™ Colon Capsule Endoscopy (PCCE) in Detection & Classification of Ulcerative Colitis
NCT00604422 ·Status: COMPLETED
-
Confocal Laser Endomicroscopy for the Detection of Gastric Intestinal Metaplasia: a Randomized Controlled Trial
NCT01024621 ·Status: COMPLETED ·Phase: NA
-
Can Steerable Capsule Endoscopy Enhance Gastric Emptying?
NCT02282852 ·Status: COMPLETED ·Phase: NA
-
Mini-sized MCE for Detection of Small Bowel in Children Under the Age of 10 Years
NCT05522101 ·Status: UNKNOWN ·Phase: NA
-
To Evaluate the Feasibility, Safety, and Efficacy of TET for FMT Via Colonic Approach
NCT02560727 ·Status: UNKNOWN
-
A Multicenter Study Evaluating the Effectiveness of Endo.Angel in Improving the Quality of Colonoscopy
NCT04102631 ·Status: UNKNOWN ·Phase: NA
-
Detachable String Magnetically Controlled Capsule Endoscopy for Completely Viewing of Esophagus and Stomach
NCT03457909 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Safety of FMT Capsule Treating Steroid-refractory GI-aGvHD
NCT04622475 ·Status: UNKNOWN ·Phase: NA
-
Utility of Motorized Spiral Enteroscopy for Suspected Small Bowel Pathology
NCT04152239 ·Status: TERMINATED
-
Confocal Probe-based Endoscopic Imaging, Colorectal Cancer, Gastrointestinal (GI) Pathologies
NCT00874263 ·Status: COMPLETED
-
A Real-time Quality Control System of Magnetic-controlled Capsule Gastroscopy
NCT04954677 ·Status: COMPLETED ·Phase: NA
-
Comparison of Diagnostic Accuracies of Various Endoscopic Examination Techniques
NCT03109938 ·Status: UNKNOWN
-
Feasibility of Remote MCE for Upper GI Tract Examination Under Five-generation Network
NCT04670692 ·Status: COMPLETED ·Phase: NA
-
Role of AI in CE for the Identification of SB Lesions in Patients With Small Intestinal Bleeding.
NCT04821349 ·Status: COMPLETED ·Phase: NA
-
I-scan With Magnification for the Detection of Gastric Intestinal Metaplasia
NCT02516735 ·Status: UNKNOWN ·Phase: NA
-
Efficacy of NICE Classification in the Histological Evaluation of Colorectal Lesions
NCT02033980 ·Status: UNKNOWN ·Phase: NA
-
Efficacy of Wireless Capsule Endoscopy and CT Enterography in Obscure Gastrointestinal Bleeding
NCT02219568 ·Status: COMPLETED ·Phase: NA
-
Esophageal and Gastric Diseases With Robotically Controlled Magnetic Capsule Endoscopy
NCT04068480 ·Status: RECRUITING