Bone Microarchitectural Database Constitution From HR-pQCT Device in Clinical Situation Potentially Associated With Bone Loss

NCT02532439 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 287

Last updated 2024-02-06

No results posted yet for this study

Summary

Bone fracture occurrence is associated with an increasing of morbidity and mortality. Some factors of fracture occurrence have been highlighted. For example, some diseases or therapy are known to increased risk of bone fracture only in some patients. Accordingly, it is important for clinicians to identify patients at risk for bone fracture. Right now, various tools are available for the clinicians:

* clinical exam,
* bone mineral density assessed by Dual Energy X-ray Absorptiometry (DEXA),
* an algorithm based on interrogation, clinical exam and bone mineral density. However, prediction of bone fracture risk needs to be improved since only 50% of bone fractures can be predicted. DEXA provides information for fracture risk estimation, but it is unable to distinguish cortical part to trabecular part. It also fails to quantify the microstructural properties that influence bone strength. Bone microarchitecture, including the cortical compartment can now be assessed in vivo by the HR-pQCT. This technique allows access to several parameters: on the one hand the volumetric bone mineral density for the whole area measured as well as cortical and trabecular regions, and on the other hand, the thickness and cortical porosity and the number of trabecular, their orientation and distribution.

Thus, the HR-pQCT allows realizing a virtual bone biopsy and provides information on cortical and trabecular bone microarchitecture. This is the only noninvasive way to assess cortical and trabecular bone microarchitecture.

Conditions

Interventions

DEVICE

HR-pQCT

Xtreme CT® device is a high resolution peripheral quantitative computed tomography (HR-pQCT) used to measure bone density and quantify the bone architecture to 3D at the extremities of the human body. For the study, the device will be used to assess bone density and microarchitecture at the forearm and shin for a systemic effect. In rheumatoid arthritis, bone density and microarchitecture will also be measured at the metacarpophalangeal.

DEVICE

DEXA

The Lunar Dual Energy X-ray Absorptiometry (DEXA) is a third generation multi-captor DEXA device that allow short duration measurements. It measures Bone Mineral Density (BMD) at the spine and the femoral neck

DEVICE

pQCT

Peripheral Quantitative Computed Tomography (pQCT) will be performed and measure bone and muscle parameters.

Sponsors & Collaborators

  • Centre Hospitalier Universitaire de Saint Etienne

    lead OTHER

Principal Investigators

  • Thierry Thomas, PhD · CHU SAINT-ETIENNE

Study Design

Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2015-03-18
Primary Completion
2019-03-18
Completion
2019-03-18

Countries

  • France

Study Locations