Short-term Outcomes of Iridoplasty for Persistent Angle Closure Despite Patent Iridotomies
NCT02199158 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10
Last updated 2014-07-24
Summary
Purpose:
To evaluate short-term angle opening after argon peripheral iridoplasty using AS-OCT and to report its complications at 1-week and 1-month follow up in patients that did not achieve a satisfactory clinical angle opening despite patent laser peripheral iridotomy.
Design:
Prospective, Interventional case series
Subjects:
Patients with an occludable angle in more than two quadrants in dark room indentation gonioscopy and patent iridotomies of at least 2 weeks, with assessment of persistent angle closure aetiology by ultrabiomicroscopy and A-scan ultrasound are included.
Patients will undergo complete examination and AS-OCT before ALPI, one week and one month after it. We analyzed the images in a masked manner and took the angle measurements (AOD500, AOD 750, TISA500, TISA750, ARA500, ARA 750, Lens vault) at 0° and 180° as the main outcome measure to determine effectiveness.
Conditions
- Angle Closure Glaucoma
- Glaucoma
Interventions
- PROCEDURE
-
Argon Laser Peripheral Iridoplasty
ALPI was applied with a VISULAS diode laser of 532 nm (Carl Zeiss Meditec, Dublin, CA) by the same ophthalmologist (JML). Twenty to 40 spots of 400 mW power with 500 microns of size and duration of 500 ms were applied. Power was modified arbitrarily until an effective iris contraction was obtained. It was considered an effective contraction as that which causes a concentric movement around the laser spot, with minimal iris pigmentation and immediate angle opening observed through the lens mirrors using a Goldmann lens. Power was lowered if there was any bursting sound perceived, pigment dispersion, air bubbles or considerable pain.
Sponsors & Collaborators
-
Instituto de Oftalmología Fundación Conde de Valenciana
lead OTHER
Principal Investigators
-
Jorge-Emmanuel Morales-León, MD · "Fundación Conde de Valenciana" Ophthalmology Institute
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-07-31
- Primary Completion
- 2012-11-30
- Completion
- 2013-01-31
Countries
- Mexico
Study Locations
More Related Trials
-
Predicting the Effect of Laser Peripheral Iridotomy
NCT04495491 ·Status: UNKNOWN
-
Laser Peripheral Iridotomy Plus Laser Peripheral Iridoplasty for Primary Angle Closure
NCT02613013 ·Status: UNKNOWN ·Phase: NA
-
Comparative Effectiveness of Treatment Strategies for Primary Open-Angle Glaucoma
NCT01645319 ·Status: COMPLETED
-
Sequential Laser Iridotomy Using Argon and Q-Switched 532 nm Frequency Doubled Neodymium Yag Laser: A Pilot Study
NCT00452998 ·Status: COMPLETED ·Phase: NA
-
ALPI vs Medical Therapy Effects on Optic Nerve Structure & Function
NCT00485238 ·Status: UNKNOWN ·Phase: PHASE4
-
Effect of Peripheral Laser Iridotomy Placement on Post-operative Visual Function
NCT03352492 ·Status: UNKNOWN ·Phase: NA
-
Is the Reduction in IOP After Treatment of 180 Degrees Equivalent to Treatment of 360 Degrees With SLT?
NCT03529591 ·Status: COMPLETED ·Phase: NA
-
Argon Laser Peripheral Iridoplasty for Primary Angle Closure Glaucoma
NCT00980473 ·Status: UNKNOWN ·Phase: PHASE3
-
Effects of Selective Laser Trabeculoplasty
NCT00986141 ·Status: TERMINATED
-
Retinal Vascular Reactivity in Subjects With Newly Diagnosed Glaucoma Before and After Selective Laser Trabeculoplasty
NCT01209975 ·Status: UNKNOWN
-
Evaluation of the Efficacy of Selecta Laser Trabeculoplasty in Patients Undergoing Filtering Surgery
NCT05900063 ·Status: COMPLETED
-
EXTERNAL SLT Treatment in Patients With Uncontrolled OPEN ANGLE GLAUCOMA
NCT01384149 ·Status: COMPLETED ·Phase: PHASE1
-
Micropulse Laser Trabeculoplasty (532nm) Versus Conventional Laser Trabeculoplasty (532nm)
NCT01788319 ·Status: COMPLETED ·Phase: NA
-
IOP Pattern in Primary Angle Closure and Primary Angle Closure Glaucoma Patients, Before and After LPI
NCT01906151 ·Status: WITHDRAWN ·Phase: NA
-
Assessment of Effectiveness Ex-Press Surgery Modification
NCT03800589 ·Status: COMPLETED ·Phase: NA
-
Surgical Treatment of Refractory Open Angle Glaucoma
NCT01212861 ·Status: COMPLETED ·Phase: NA
-
Eye Pressure Lowering Surgery
NCT01931904 ·Status: RECRUITING
-
Efficacy of Selective Laser Trabeculoplasty Targeting Nasal Versus Inferior 180-degree
NCT06851546 ·Status: COMPLETED ·Phase: NA
-
Combined Phacoemulsification and Diode Laser Therapy in Chronic Angle Closure Glaucoma
NCT05576493 ·Status: UNKNOWN ·Phase: NA
-
Timing of Treatment Completion in Staged Selective Laser Trabeculoplasty (SLT): Early vs. Late Completion
NCT00551395 ·Status: TERMINATED ·Phase: PHASE3
-
Advanced Glaucoma Progression Study
NCT01742819 ·Status: ACTIVE_NOT_RECRUITING
-
Treatment Outcomes of a Novel Glaucoma Tube Shunt Implant for Intraocular Pressure Control in Eyes With Refractory Glaucoma
NCT04297930 ·Status: COMPLETED
-
Reduction of Intraocular Pressure After I-stent By-pass Implantation in Eyes With Open Angle Glaucoma
NCT03807869 ·Status: COMPLETED ·Phase: NA
-
Clinical Study of LPI on Different Sites of Iris
NCT02870504 ·Status: UNKNOWN ·Phase: NA
-
A Trial to Compare the Laser Treatment (SLT vs. ALT) in Glaucoma Patients
NCT01687465 ·Status: UNKNOWN ·Phase: PHASE3