Waterproof Casting for Pediatric Distal Radius Fractures
NCT02095106 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 27
Last updated 2017-12-02
Summary
Distal radius fractures are one of the most commonly seen fractures in children. Traditionally, minimally angulated or non-displaced distal radius fractures are treated with short or long-arm cast immobilization for up to 8 weeks. The traditional fiberglass casts used must be kept dry to prevent inflammation and potential infection. If a fiberglass cast gets wet, it must be removed and replaced. In general, waterproof casting has been shown to improve patient comfort and overall satisfaction.
We intend to explore the efficacy of a new, waterproof cast made of a hybrid mesh in the treatment of minimally angulated distal radius fractures in children using a randomized, controlled, cross-over study design. We will include patients between 4 and 14 years of age with minimally angulated distal radius fractures (\<15 degrees of angulation on sagittal or coronal planes) presented to the Orthopaedic Institute for Children Urgent Care Facility within 7 days of injury. As determined by a power analysis, a total of 26 patients will be enrolled in the study.
Patients eligible for the study will be randomized into one of two equally sized (n=13) groups: patients in Group 1 will receive a short arm cast made of the waterproof hybrid mesh material and patients in Group 2 will receive a regular fiberglass cast. Both groups will follow-up at two weeks for clinical and radiological evaluation, after which they will be transitioned into a regular fiberglass cast (Group 1) or a hybrid mesh waterproof cast (Group 2) for an additional two weeks. This crossover will allow both groups to experience each type of cast. After four weeks of immobilization, patients in both groups will discontinue casting and be advised to avoid contact sports or strenuous activities until week 8.
Patients in both groups will follow up 8 weeks after initial treatment for clinical and radiological evaluation to evaluate range of motion, pain, and fracture alignment. Physical function will be evaluated at weeks 1, 2, and 4 using the Activities Scale for Kids - Performance, a validated, highly reliable, self-reported measure that assesses physical function in children between 5 and 15 years. Pain will be evaluated using the Faces Pain Scale, a validated, highly reliable scale commonly used in the pediatric population. Patient satisfaction will be measured at Weeks 1, 2, and 4, and the radiographs at Week 8 will be compared with initial radiographs to assess fracture displacement and angulation. Skin changes will be assessed at week 2 and week 4 by an independent observer blinded to the type of cast that has been removed and digital photographs will be obtained and analyzed using ImageJ Image Processing and Analysis Software to calculate the surface area of any described skin changes as a percentage of total skin area originally covered by the cast. Itching will be assessed at weeks 1, 2, and 4 using a visual analogue scale in which a horizontal line of 100 mm will be presented to the patient with "no itching" at the left end of the scale and "strongest itching" at the right end.
We hope to determine whether the new, waterproof cast can result in similar clinical outcomes and patient satisfaction for distal radius fractures as compared with the traditional fiberglass cast.
Conditions
- Pediatric Distal Radius Fractures
Interventions
- DEVICE
-
Waterproof Cast
- DEVICE
-
Traditional cast
Sponsors & Collaborators
-
University of California, Los Angeles
lead OTHER
Principal Investigators
-
Mauricio Silva, MD · UCLA, Orthopaedic Institute for Children
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 4 Years
- Max Age
- 14 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2014-04-30
- Primary Completion
- 2015-10-31
- Completion
- 2015-10-31
Countries
- United States
Study Locations
More Related Trials
-
Closed Reduction of Distal Forearm Fractures by Pediatric Emergency Medicine Physicians: A Prospective Study
NCT01101607 ·Status: COMPLETED ·Phase: NA
-
Long Arm Vs Short Arm Fiberglass Cast for Treatment of Displaced Distal Radius Fractures
NCT03835065 ·Status: WITHDRAWN ·Phase: NA
-
Management of Pediatric Distal Radius Fractures : Conservative Treatment Versus Surgical Reduction
NCT06459557 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Treatment of Distal Radius Buckle Fractures
NCT01762605 ·Status: TERMINATED ·Phase: NA
-
Comparing Forearm and Upper Arm Combi Cast for Distal Forearm Fractures in Children
NCT03297047 ·Status: COMPLETED ·Phase: NA
-
Investigation of a Medical Device for the Immobilisation of Radius and Ulna Fractures in Paediatric Patients
NCT06312995 ·Status: RECRUITING ·Phase: NA
-
Is Casting of Displaced Pediatric Distal Forearm Fractures Non-inferior to Reduction in General Anesthesia?
NCT05736068 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Timing of Bridge Plate Removal and Distal Radius Fracture Outcomes
NCT05578612 ·Status: WITHDRAWN ·Phase: NA
-
Management of Distal Radius Fractures in Children Younger Than 11 Years Old.
NCT02670629 ·Status: COMPLETED ·Phase: NA
-
Prospective Evaluation of Cast Bivalving for Pediatric Distal Radius Fractures
NCT05716438 ·Status: UNKNOWN
-
Clinical Evaluation of Cast21 Short Arm Product During Treatment of Distal Radial or Distal Ulnar Fractures
NCT06304649 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Cast vs. Splints for Minimally Displaced Distal Radius Fractures in the Elderly
NCT02066857 ·Status: COMPLETED ·Phase: NA
-
Short and Long-arm Fiberglass Cast Immobilization for Distal Salter Harris I and II Forearm Fractures in Children
NCT05156749 ·Status: RECRUITING ·Phase: NA
-
Distal Radius Buckle Fracture Follow up Study
NCT03248687 ·Status: COMPLETED ·Phase: NA
-
Biobased Polyester Versus Synthetic Fiberglass Casts for Treating Stable Upper Limb Fractures in Children
NCT06102603 ·Status: COMPLETED ·Phase: NA
-
Internal Fixation of Lateral Humeral Condyle Fractures With Absorbable Screws in Children
NCT02733666 ·Status: COMPLETED ·Phase: PHASE1
-
Short Versus Conventional Plaster Cast Fixation Time in Reduced Distal Radius Fractures
NCT02798614 ·Status: COMPLETED ·Phase: NA
-
Removable Splint Versus Cast in the Treatment of Distal Radius Fracture in Children
NCT05244317 ·Status: WITHDRAWN ·Phase: NA
-
Extended vs Flexed Elbow Casting
NCT03935516 ·Status: WITHDRAWN ·Phase: NA
-
Distal Radius Buckle Fracture RCT
NCT04032873 ·Status: COMPLETED ·Phase: NA
-
Fixation of Unstable Distal Radius Fractures
NCT00654615 ·Status: COMPLETED ·Phase: NA
-
Randomized Trial of Casting Techniques for Displaced Forearm Fractures
NCT00823823 ·Status: COMPLETED ·Phase: NA
-
Complications in Distal Radius Fracture
NCT03311633 ·Status: COMPLETED ·Phase: NA
-
Above-versus Below-elbow Casting for Conservative Treatment of Distal Radius Fractures
NCT03126175 ·Status: COMPLETED ·Phase: NA
-
Kirschner Wires Fixation Versus Cannulated Screws Internal Fixation for Displaced Lateral Condyle Humeral Fracture in Children
NCT05409053 ·Status: UNKNOWN ·Phase: NA