Comparison of "Wet Suction" Technique to Contemporary "Dry Suction" Technique Using a 22 Gauge Needle for EUS FNA
NCT01720745 · Status: TERMINATED · Type: OBSERVATIONAL · Enrollment: 128
Last updated 2019-11-01
Summary
ROLE OF SUCTION IN EUS-FNA: Current suction technique involves suctioning the aspirate into the needle that has an air column. The needle is not flushed with any liquid prior to passing into the desired solid lesion. Suction is applied when the needle is within the lesion leading to aspiration of tissue into the needle. This is the standard technique and some have done with and without the stylet. There are some data that favor non use of a stylet.
WET SCTION TECHNIQUE:
Wet suction technique involves flushing the needle with 1-2 cc of saline to replace the column of air with saline. The needle is now passed into the desired lesion. Suction is applied at maximal strength and needle moved back and forth within the lesion to obtain as aspirate. Drops of saline can be seen moving into the suction syringe as the aspirate moves into the needle. Needle is now withdrawn and aspirate delivered on to a slide by using a stylet and or flushing air into the needle with a syringe.
HYPOTHESIS The effect of suction for the purpose of aspirating cells and / or tissue during fine needle biopsy may be significantly improved by filling the column of the needle with a less compressible fluid. The volume of vacuum being pulled may be negatively impacted by the expansion of air within the needle. Replacing the air with sterile saline may thus improve the suction transferred to the needle tip by ensuring that the full volume of the vacuum syringe is transferred to the distal tip of the needle. This effect would be most pronounced in larger gauge needles which would have a larger internal volume. An additional benefit of filling the needle with saline prior to aspiration is the speed of the pressure transfer. The theory is that the air in the needle may absorb some of the force of the sudden application of vacuum. A column of saline in the needle may increase the velocity of the pressure transfer providing more tissue and less blood.
Conditions
- Cancer
- Infection
- Inflammation
- Tumor
- Sarcoid
- Lymphadenopathy
- Lymphoma
Sponsors & Collaborators
- lead OTHER
Principal Investigators
-
RAJEEV ATTAM, MD · University of Minnesota
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2012-10-31
- Primary Completion
- 2014-09-30
- Completion
- 2014-09-30
Countries
- United States
Study Locations
More Related Trials
-
The Comparison of Wet Suction and Dry Suction Technique in EUS-FNA for the Outcomes in Pancreatic Solid Lesions
NCT03821974 ·Status: COMPLETED ·Phase: NA
-
Accuracy Between Transthoracal Needle Aspiration (TTNA) Techniques in Suspected Lung Cancer Patients
NCT07255950 ·Status: RECRUITING ·Phase: NA
-
Comparision of EUS-FNB Techniques for Diagnose of Solid Pancreatic Lesions
NCT05549856 ·Status: UNKNOWN ·Phase: NA
-
EUS-FNA With and Without Suction
NCT02072915 ·Status: COMPLETED ·Phase: NA
-
Wet-suction Versus Slow-pull for EUS-FNB of Solid Lesions
NCT04834193 ·Status: COMPLETED ·Phase: NA
-
Trial of Endobronchial Ultrasound Guided Fine Needle Aspiration Techniques
NCT01741571 ·Status: COMPLETED ·Phase: NA
-
Comparison of EUS-Guided Fine Needle Aspiration Technique
NCT01923883 ·Status: UNKNOWN ·Phase: NA
-
EUS-guided Fine Needle Aspiration (EUS-FNA) Versus EUS-guided Fine Needle Biopsy (EUS-FNB) for Diagnosis of Subepithelial Tumors
NCT02943837 ·Status: WITHDRAWN ·Phase: NA
-
Comparison of Three Tissue Acquiring Techniques During EUS Guided Biopsies of Solid Tumors.
NCT03264092 ·Status: TERMINATED ·Phase: NA
-
Endobronchial Ultrasound-Guided Transbronchial Needle-Aspiration With Suction in Obtaining Samples From Patients With Suspected Nodal Metastatic Lung Cancer
NCT04116970 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration Using a 22 vs 25-Gauge Needle
NCT03004586 ·Status: COMPLETED ·Phase: NA
-
Endobronchial Ultrasound Needle Aspiration With and Without Suction
NCT05110950 ·Status: UNKNOWN ·Phase: NA
-
Endobronchial Ultrasound Transbronchial Needle Aspiration Using Needle Suction Versus No Suction
NCT01734980 ·Status: COMPLETED ·Phase: NA
-
The Efficacy of Shear-wave Elastography-guided Aspiration and Biopsy for Diagnosis in Lung Tumor
NCT03881410 ·Status: COMPLETED ·Phase: NA
-
Liquid Biopsy Assay of EBUS-TBNA Supernatant Fluid for Diagnosing Lung Cancer
NCT06889467 ·Status: RECRUITING
-
Yield of Endoscopic Ultrasound Guided Fine Needle Aspiration (EUS-FNA) With and Without the Use of a Stylet in the Biopsy Needle
NCT01241799 ·Status: COMPLETED ·Phase: NA
-
Comparison of Three Different Puncture Techniques in EBUS-TBNA
NCT05628454 ·Status: COMPLETED ·Phase: NA
-
EUS-FNA With 22G Procore Needles vs 22G Conventional Needles
NCT01581762 ·Status: COMPLETED ·Phase: PHASE3
-
Procedural Outcomes in Endobronchial Ultrasound - Transbronchial Needle Aspiration (EBUS-TBNA) With and Without Rapid On-Site Evaluation (ROSE)
NCT02028052 ·Status: TERMINATED ·Phase: NA
-
Image-Guided Pleural Needle Biopsy in Pleural Diseases
NCT06541470 ·Status: COMPLETED ·Phase: NA
-
Endobronchial Ultrasound vs Mediastinoscopy in NSCLC
NCT00372203 ·Status: COMPLETED ·Phase: PHASE2
-
Diagnostic Yield and Safety of Confocal Laser Endomicroscopy-Assisted Endobronchial Ultrasound-Guided Transbronchial Needle Aspiration
NCT07040670 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
False/Negative Rate of Lung Percutaneous Needle Biopsy
NCT00638352 ·Status: COMPLETED
-
Utility of Endobronchial Ultrasound Guided Needle Biopsy in Early Stage Non- Small Cell Lung Cancer (NSCLC)
NCT00832715 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Comparison of Two Needle Aspiration Techniques for Endoscopic Ultrasound-guided Fine Needle Aspiration (EUS-FNA) in Solid Pancreatic Lesions
NCT01936467 ·Status: COMPLETED ·Phase: PHASE3